Download presentation
Presentation is loading. Please wait.
Published byWarren Collins Modified over 9 years ago
1
HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July 2008
2
Electromagnetic Channel Hadronic Channel LED data Run 977
3
Electromagnetic Channel Hadronic Channel Source Data Gains from DBS
4
Electromagnetic Channel Hadronic Channel
5
Electromagnetic Channel Hadronic Channel = 33,35,38,39, =3 = 40, =63,67 = 32,38,39,40 =3 = 40 =63,67
6
Low intensity LED Run 53000 (1350 V) SPE i : the single photoelectron response C i =( * SPE i ) -1 ~ 0.28/GeV calib.cefff ~1/gain
7
Rechit occupancies from Cruzet 3 data
8
HF Rechits in Cruzet 3 data
9
Jet construction in Cruzet3
10
LED run 53000 Low RMS
11
(SPE V2 /SPE V1 )=(V2/V1) = 5.08 Comparison of gains at different HV
12
Electromagnetic Channe l Hadronic Channel C 1100 /C 1150 Comparison of the calib Coefficients which are in DB
13
C 1100 /C 1250
14
C 1100 /C 1350
15
C 1150 /C 1250
16
C 1150 /C 1350
17
C 1250 /C 1350
18
Next step: - we need more data (Low intensity LED runs) for HFM (and also HFP) - more analysis of Cruzet data -
19
Backup slides
20
Validation studies for HF Calibration Documentation of Single Photoelectron Peak measurements and source for the calibration: CMS IN 2006/037; 9'th ICATTP, World Scientiic pp 339-342 (2006); CMS IN 2006/044; CMS IN 2006/045; CMS IN 2006/138; CMS IN 2007/012 ;CMS IN 2007/018; CMS IN-2008/015; and more.. Preliminary results from - SPE vs Data Base comparison - analysis of HF LED runs using SPE gains and Data Base gains -Cosmic ray data analysis calib. coefficients in DB 1150V gain ratio PMT(1250V)/PMT(1150V) =1.5 calib.cefff ~1/gain calib.cefff ~1/gain calib. coeff(1250V) = calib.coeff(1150V) * 0.66
21
HF- hadronic channels HF+ hadronic channels HF Calibration coefficients from Data Base (GeV/fC) frontier://Frontier/CMS_COND_20X_HCAL HF- electromagnetic channels HF+ electromagnetic channels Mean ~0.22 GeV/fC RMS ~0.06 GeV/fC Mean ~0.20 GeV/fC RMS ~0.04 GeV/fC Mean ~0.35 GeV/fC RMS ~0.09 GeV/fC Mean ~0.31 GeV/fC RMS ~0.06 GeV/fC
22
Electromagnetic channels (long fibers) Hadronic channels (short fibers) Comparison of the calibration constants (C i ) of LED and DB gains (C_src) C i = ( * SPE i ) -1 where is the mean number of generated photoelectrons/GeV and SPE i is the single photoelectron response of the ith channel (similar method as in CMS IN 2007/018) ~ 0.28/GeV from analysis of 100 GeV electron data taken in 2004 test beam. HF+ Run 977 (100 K events) at low LED intensity (1350 V)
23
Electromagnetic channels Hadronic channels Mean = 0.92 RMS=0.12 Mean = 0.91 RMS=0.12
24
RMS ~ 0.48 GeV RMS ~ 0.75 GeV RMS ~ 0.68 GeV RMS ~ 0.43 GeV Cruzet 3 Run 51403 (CSC, DT, HCAL trigger)
25
HF Calibration coefficients from Data Base frontier://Frontier/CMS_COND_20X_HCAL Electromagnetic channels (long fibers) Cruzet 3 run 51403 (Shift in binning !) Reflections of the gains in the cosmic muon data
26
HF Calibration coefficients from Data Base frontier://Frontier/CMS_COND_20X_HCAL hadronic channels (short fibers) Cruzet 3 run 51403 (Shift in binning !) Reflections of the gains in the cosmic muon data
Similar presentations