Range & Specifications
9
CASE #1: 80% stenosis of the left renal artery located at the ostium of the vessel. HELIOS 6x13
10
CASE #1: A 0.014’’ guide wire was positioned in the renal artery. The Helios renal stent 6x13mm was implanted without predilatation at the ostium of the vessel (10 atm). A flare of the ostium was made by the same stent balloon. The angiographic result was very good
11
CASE #2: 80% stenosis of the left & right renal arteries located at the ostium of the vessel.
12
CASE #2: The Helios renal stent 7x13mm was implanted without predilatation at the ostium of the right renal artery. The angiographic result was very good.
13
CASE #2: The Helios renal stent 6x16mm was implanted after predilatation at the ostium of the left renal artery. The angiographic result was very good.