1 Retrofit and Conditioning
STULZ Solutions and Services (2nd Edition) STULZ mission is to be the premier provider of energy efficient temperature and humidity control solutions for mission critical applications. Outdoor Cooling Indoor Cooling Retrofit and Conditioning

2 STULZ, Your Trusted Partner
STULZ is a global provider of innovative data center cooling solutions and services. Cooling Technology Leader -Precision cooling solutions and services for mission critical applications. -Energy efficient temperature and humidity control equipment for data centers. Pre-Engineered -Variety of configurations and options. -Factory designed and tested components. -Custom touch to meet your specific needs. Breadth and Depth -20 years of expertise including controls & economizers. -Largest portfolio to fill all needs. Designed and Manufactured in the U.S.A. -Research, design, manufacture, and test in Frederick, MD. -Meets the requirements of Buy America Act

3 STULZ, Your Trusted Partner
STULZ can be found in most of the world’s leading data centers. STULZ works closely with leading companies of all sizes to provide you with a complete data center cooling solution. Consulting Engineers • Most Extensive Cooling Line • Unit Selection Support • Energy Analysis • Electrical & Mechanical Drawings • Custom Designs Contractors • General & Mechanical • High Value • Competitive Lead Times • Controls Support • Start-up Service Owners/Users • High Quality & Reliability • Low Maintenance • After Sales Service • Fast ROI Partners • Partnerships with Rack, Containment, DCIM, and Cooling Tower Experts

4 STULZ Mission Critical Cooling Solutions

5 STULZ Mission Critical Cooling Solutions
Energy Efficiency Energy efficient temperature and humidity control products and solutions for mission critical applications. Largest sensible cooling capacity per ft2. Qualify for energy rebates. Save money. ASHRAE Active participant on ASHRAE ASHRAE TC data center temperature & RH ASHRAE /2013 use of water and air economizers ASHRAE 127 test standard Achieve industry best SCOP and PUE performances. Testing & Certifications STULZ Mission Energy Lab ETL Satellite laboratory for ASHRAE 127 testing Research, Development and 3rd party witness testing IBC / OSHPD approved CEC (California Energy Commission Meet key industry standards. Assure performance as advertised.

6 STULZ E2 Controller Ties it all Together
STULZ Controls and Monitoring STULZ E2 Microprocessor Controller STULZ E2 is the standard microprocessor controller across all STULZ product platforms Provides precision monitoring and control of your mission critical environment. STULZ E2 Controller Ties it all Together Designed specifically for precision control of mission critical environments Multiple I/O capabilities for sensor inputs and control outputs. Universal BMS interface for remote monitoring (read) and remote control (write) Capable of networking controllers in a workgroup (pLAN) to work as one (no BMS required) Pre-engineered controls for economizers and adiabatic cooling

7 STULZ Controls and Monitoring
Control Panel Backlit LCD alphanumeric display for visual indication Operated via 6-key menus, in five different modes Unit functions for cooling, heating, humidifying and dehumidifying Three levels of restricted entry into the configuration Microprocessor Sensor inputs and control outputs Additional I/O Sensors & Alarms Psychrometric control provided as user configurable temperature and humidity (RH) or dew point control Optional UPS backup module Control Panel with Touchscreen Microprocessor

8 STULZ Controls and Monitoring
Software Independent EC Fan and cooling control (CW valve or DX) Cooling control options: return air temperature, humidity, supply air temperature, dew point Fan control sequence: BMS, local/static pressure, or temperature based (supply or return air) Networking Capable of networking up to eight E2 controllers with an independent LAN. The E2 controller will communicate to BMS/BAS systems via all common protocols: BACnet IP/Ethernet/MS-TP, HTTP, SNMP V1/2c, Modbus IP/RTU Control Panel with Touchscreen Microprocessor

9 STULZ Controls and Monitoring
STULZ Advanced Controls Easy to program multiple alarms including “virtual flow” alarm and “condensate possible” alarm Real Time Monitoring -Provides a direct LAN connection for real time status of the EC fans. -Data points available to a BMS for advanced system monitoring. Real time data includes: • Speed • Power • Temperature • Voltage • Alarm Status Multiple Sensor Averaging Control (up to 4 temperature or humidity sensors) • Refrigerant pressure and temp monitoring for DX • Water temp. sensor for CW • Return or supply temp/humidity sensor • Static pressure sensor LAN communication options available Ultra capacitor system can intelligently close valves or dampers after a sudden power loss

10 STULZ Controls and Monitoring
STULZ E2 Microprocessor Controller Key Control Capabilities Benefit Independent Control Efficiency of EC Fans and CW valve (or DX compressor) can be maximized Dew Point Control Temperature and RH examined and humidification / dehumidification modes optimized Static Pressure Control Provides even airflow on demand at any room position and precise control for containment Unit Networking Capable of BMS interface or private local area network (pLAN) Redundancy Controller defaults to set points if a sensor fails or if BMS control signal fails, EC Fans ramp up if one fails

11 Decision Criteria for Choosing an Economizer Type
STULZ Economizers – Controls & Monitoring Decision Criteria for Choosing an Economizer Type Weather Conditions (bin weather data) Dry Bulb, Wet Bulb Enthalpy, Dew Point Air-Side Economizer Quality of Air (particulates?) Willingness to bring outside air into the data center Ability to duct outside air through the building Water-Side Economizer Availability and cost of water Capital Budget (CapEx) and Operating Budget (OpEx) Maintenance Capability The STULZ E2 Controller monitors and controls all aspects of economizer system operation to economically provide the required cooling, based on real time indoor and outdoor conditions

12 Pre-Engineered Controls
STULZ Air-Side Economizer Air-Side Economizer with STULZ CRAC’s, CRAH’s, or AHU’s and E2 Controls Pre-Engineered Controls STULZ E2 Inputs Outside Air Temperature & humidity Supply / Return air temperature BMS control STULZ E2 Outputs STULZ CRAC, CRAH or AHU Outside Air Intake Direct or indirect adiabatic cooling (if equipped) STULZ DX or CW operation (if needed) STULZ EC Fans Return Air Damper and Exhaust Damper or Fan Modes of Operation Warmer / High Humidity Outside air dampers close Direct or indirect adiabatic deactivated CRAC/CRAH with traditional operation Within Proper Range Outside air dampers open Direct or indirect adiabatic activated Cold Conditions Dampers mix outside air & return air to achieve desired temperature Warm return air mixes with outside air before the filter to prevent freezing

13 STULZ Air-Side Economizer
Vertical & Horizontal Mixing Boxes STULZ vertical and horizontal mixing boxes for air-side economizer options using STULZ floor-standing CRAC’s or CRAH’s CRACs or CRAHs with an integrated mixing box and damper controls provide direct free cooling Units attached to the top of a CRAC or CRAH in a vertical or horizontal position Pre-filter and freeze protection damper options Mixes outside and return air depending on outside air conditions Full economizer controls provided by the STULZ CRAC or CRAH

14 STULZ Air-Side Economizer
STULZ CyberHandler (AHU) with Direct Air Economizer, Direct Adiabatic Cooling, and DX for trim Direct Air-Side Economizer Outside air (less than supply air temp) is directly introduced into the data center Direct Adiabatic Cooling The outside air is cooled with an adiabatic system and directly introduced into the data center Direct DX Cooling The outside and/or return air is cooled with a DX evaporator coil and directly introduced into the data center

15 STULZ Air-Side Economizer
STULZ CyberCon (Modular/Container) with Direct Air Economizer, Direct Adiabatic Cooling, and DX for trim Direct Air-Side Economizer Outside air (less than supply air temp) is directly introduced into the data center Direct Adiabatic Cooling The outside air is cooled with an adiabatic system and directly introduced into the data center Direct DX Cooling The outside and/or return air is cooled with a DX evaporator coil and directly introduced into the data center

16 Indirect Adiabatic Cooling Module
STULZ Air-Side Economizer STULZ CyberHandler with Indirect Air Economizer, Indirect Adiabatic Cooling, and DX for trim Indirect Adiabatic Cooling Module Indirect Air-Side Economizer Outside Air (less than supply air temp) passes through an air-to-air heat exchanger to indirectly cool the data center return air Indirect Adiabatic Cooling The return air is indirectly cooled via an air-to-air heat exchanger that has an adiabatic spray applied to it

17 Pre-Engineered Controls
STULZ Water-Side Economizer Water-Side Economizer with STULZ CRAC’s and E2 Controls Pre-Engineered Controls STULZ E2 Inputs Outside Air Temperature & humidity Supply / Return air temperature BMS control STULZ E2 Outputs STULZ CRAC Varies the speed of the Dry Cooler or Cooling Tower fans and Pump Package to optimize free cooling Uses the Dry Cooler or Cooling Tower for primary cooling - based on fluid temperature Activates the compressor when DX trim or full DX cooling is required Modes of Operation Warmer / High Humidity CRAC traditional operation; dry cooler supplies glycol to unit condenser Within Proper Range CRAC has combination of glycol Free Cooling (FC) Coil & one DX Compressor (trim) Cold Conditions CRAC has glycol transferred to free cooling coil; compressor off - fans on dry coolers and pumps operate at lowest possible speeds to supply required cooling - as ambient increases, fans on dry coolers & pumps increase speed to extend available free cooling

18 STULZ Water-Side Economizer
STULZ DX CRAC with Economizer Coil & Condenser Loop DX CRAC cooling unit with water-side economizer direct expansion coil water/glycol economizer coil Cooled with fluid from the outdoor dry cooler & economizer coil (DX compressors off) When ambient temperature rises, the flow of fluid is diverted into the DX cooling circuit to provide an assist mode. When the fluid temperature is warm, the unit operates as a fluid cooled DX unit, rejecting the heat to the condenser.

19 STULZ Water-Side Economizer
Variable Economizer Cooling Variable fan speed dry cooler (with fan speed controlled based on fluid temp) Variable speed pump (controlled based on fluid temp) Water/glycol cooled free cooling CRACs (consisting of both a DX and a water/glycol economizer coil)

20 STULZ Water-Side Economizer
Evaporative Tower Economizer Cooling Closed loop evaporative cooling tower (controlled based on fluid temperature) Constant speed pump Water/glycol cooled free cooling CRACs (consisting of both a DX and a water/glycol economizer coil)

21 Pre-Engineered Controls
STULZ Water-Side Economizer Water-Side Economizer with STULZ CRAH’s and E2 Controls Pre-Engineered Controls STULZ E2 Inputs Outside Air Temperature & humidity Supply / Return air temperature BMS control STULZ E2 Outputs STULZ CRAH Modulates the STULZ CW Valve and EC Fans to extend free cooling operation Enable / Disables Chiller, Pumps, and Cooling Tower Uses the Cooling Tower for primary cooling - based on fluid temperature Activates the Chiller when trim or full cooling is required Modes of Operation Warmer / High Humidity CRAH traditional operation; cooling tower supplies primary cooling; chiller provides trim Within Proper Range CRAH uses Cooling Tower for primary cooling Cold Conditions CRAH uses cooling tower for primary cooling

22 STULZ Water-Side Economizer
Dual-Source Economizer Cooling Evaporative cooling tower (controlled based on fluid temperature) Cooling tower pump Chiller (controlled based on fluid temperature), chiller pump CRAH unit (with dual circuited interlaced chilled water cooling coil)

23 STULZ Water-Side Economizer
STULZ Dynamic Economizer Cooling The latest STULZ state-of-the-art water-side economizer solution Evaporative cooling tower and cooling tower pump Air or water cooled chiller and chiller pumps Control mixing valves CW CRAHs (with a single coil) Optimized Sequence of Operations Temp near or below required cooling fluid temperature - the “chiller assisted” cooling system operates in cooling tower mode (without energizing the chiller) Temp increases above required cooling fluid temperature - flow from the tower diverted to the chiller to provide the trim to maintain the cooling fluid temp. Designed to minimize the hours of chiller operation and optimize economization. Reference the new STULZ Data Center Design Guide for Water-Side Economizers

24 STULZ Water-Side Economizer
STULZ Dynamic Economizer Cooling – Optimized Conditions Achieve incredible efficiency by executing a carefully coordinated sequence of operations, where the functions of all components are orchestrated together. Optimized Delta-T and Approach Temperatures 5⁰F (3⁰C) delta between Supply Water & Supply Air temp 28⁰F (15⁰C) delta between the Supply Air & Return Air temp 25⁰F (14⁰C) delta between the Supply Water & Return Water temp STULZ Controls 75⁰F Supply Air 103⁰F Return Air Closed-Loop Cooling Tower STULZ CRAH 70⁰F Supply Water 95⁰F Return Water Pumps & Valves Air-Cooled Chiller

25 STULZ Water-Side Economizer
STULZ Dynamic Economizer Cooling – Optimized Conditions “CRAH Heat Transfer Efficiency” with STULZ CW V-coil and EC fan technology by increasing the return air temperature to 103F (using containment) “Warm Water Cooling” with STULZ CW V-coil that allows the use of 70F supply water to provide 75F supply air (well within ASHRAE TC9.9 guidelines). “All-Year Primary Economizer Cooling” with a closed-loop cooling tower “Chiller Assisted Cooling” using an air or water-cooled chiller “Reduced Flow and High Delta-T” by optimizing use of pumps and valves Optimized Cooling Performance Operate in Dry Tower Mode for 62% of the year Extend Closed-Loop Cooling Tower operation in wet mode another 11% Operate in Chiller Assist Mode (partial chiller operation to trim cooling tower water) for 27% of the year Contributing to a major data center PUE of 1.14 (partial or mechanical PUE of 1.06)

26 Indirect Air Economizer
STULZ CyberHandler : Pre-Engineered Air Handler STULZ CyberHandler Superior value as a pre-engineered outdoor air handling system for precision temperature and humidity control in a data center Designed with proven STULZ technology Frees up white space in the data center Capacity Table Direct Air Economizer with DX or CW Indirect Air Economizer With DX or CW kW 124 – 538 124 – 480 MBH ,836 421 – 1,638 Tons 35 – 153 35 – 137 CFM 12,000 – 55,000 12,000 – 50,000

27 STULZ CyberHandler : Pre-Engineered Air Handler
Modular Construction Pre-engineered modules configured to your needs Designed for Data Centers Handles higher return air temperatures than comfort cooling AHUs Engineered and tested for 7x24 operation Outdoor placement frees white space Keeps maintenance away from sensitive IT equipment STULZ E2 controller, available with BMS interface Galvanized Steel Base Allows Roof, Pad or Curb Mounting Sturdy Construction Excellent Corrosion Protection Hinged Access Doors Service access to all sections Double Wall Panels Excellent insulation and corrosion resistance Thermal break Lightweight Minimal deflection EC Fan Array Highly reliable Low maintenance Built in redundancy Low energy consumption Variable speed Direct drive

28 STULZ CyberHandler : Pre-Engineered Air Handler
Configure Pre-Engineered Modules to make your unique STULZ CyberHandler System Economizer Air Economizer - Direct Air (damper system) - Indirect Air (heat exchanger) Water Economizer - Dual Coil (CW) - Integrated Fluid Cooler (CW) Adiabatic Direct Adiabatic (Pad) Indirect Adiabatic (Heat Exchanger) Cooling Section Mechanical Cooling DX Coil CW Coil Humidification Electrode Canister Ultrasonic Humidifier

29 STULZ CyberHandler : Pre-Engineered Air Handler
Configure Pre-Engineered Modules to make your unique STULZ CyberHandler System EC Fan Array Section Multiple Highly Efficiency EC Fans Fan Speed Control Heat Rejection Condensing Unit for DX Fluid Cooler for CW Exhaust Exhaust Module for Direct Air Economizer Passive or Powered with EC Fans

30 STULZ CyberHandler – Configuration – Example 1
STULZ CyberHandler : Pre-Engineered Air Handler STULZ CyberHandler – Configuration – Example 1 Direct Air Economizer Direct Adiabatic Cooling DX Cooling Outside air (< supply air temp) directly introduced into the data center The outside air is cooled with an adiabatic system Used only when required for trim or full capacity

31 STULZ CyberHandler – Configuration – Example 2
STULZ CyberHandler : Pre-Engineered Air Handler STULZ CyberHandler – Configuration – Example 2 Indirect Air Economizer Indirect Adiabatic Cooling DX Cooling Outside Air (< supply air temp) through an air-to-air heat exchanger to indirectly cool the return air Return air indirectly cooled with an adiabatic spray applied to the outside air and air-to-air heat exchanger Used only when required for trim (can be sized for full capacity)

32 STULZ CyberPack: Packaged Rooftop AHU
STULZ DX packaged rooftop AHU DX Cooling Up to two independent cooling circuits with highly reliable scroll compressors. Environmentally Friendly R410A refrigerant. -30 Degrees F ambient operation with optional flooded head pressure control. Packaged AHU Functional operations: cooling, dehumidification and filtration EC Fans for energy cost savings and long life Fan speed is continuously adjustable 4” thick, MERV 7-13 cartridge air filters Controller user interface display panel for ease of use STULZ E2 Controller and user interface display panel for ease of use Capacity Table DX kW 42 – 88 MBH 144,000 – 300,000 Tons 12 – 25 CFM 5,000 – 10,000

33 STULZ CyberCon : Pre-Engineered Modular
Provides superior value for precision temperature and humidity control in a modular/containerized data center (POD). Capacity Table Direct Air Economizer With Adiabatic and/or DX Indirect Air Economizer with DX Indirect Water Economizer with Chiller kW 243 223 MBH 830 760 Tons 69 63 CFM 23,000

34 STULZ CyberCon : Pre-Engineered Modular
Designed for modular / containerized data centers Minimum mechanical installation required - only utilities (power, condensate drain) No protruding components like fans, doors, or louvers DX or CW cooling with direct or indirect adiabatic cooling option STULZ E2 controller, available with BMS interface Standard 20’ high-cube container dimension Allows IT POD, Pad, or Curb Mounting Rapid deployment Easy shipping and handling Short construction time Hinged access doors Service access to all internal components EC Fan Array Highly reliable Low maintenance Built in redundancy Low energy consumption Variable speed Direct drive Designed for growth as needed Outside air intake & service access from one long side Allows end-to-end, back-to-back installation, and modular build out

35 Container with IT Racks
STULZ CyberCon : Pre-Engineered Modular Designed for growth as needed. STULZ CyberCon allows build out of multiple modular / containerized data centers. STULZ CyberCon Container with IT Racks Add units as capacity needs increase Back-to-back and/or side-by-side configurations

36 STULZ CyberCon : Pre-Engineered Modular
Configuration – Example One Direct Air Economizer Outside air (< supply air temp) is directly introduced into the data center Direct Adiabatic Cooling Outside air cooled with an adiabatic system and directly introduced into the data center DX Cooling (Integrated DX Condenser) Used only when required for trim or full capacity

37 STULZ CyberCon : Pre-Engineered Modular
Configuration – Example Two Indirect Water Economizer Outside air cools water in a closed loop Integrated Adiabatic Fluid Cooler Adiabatic cooling of closed water loop when more cooling is needed than water economizer can provide Integrated Chiller Chiller to trim closed water loop temperature if outside conditions are not suitable for water economizer or adiabatic fluid cooler only STULZ CyberCon modular system, with integrated indirect water-side economizer cooling, based on STULZ Dynamic Economizer Cooling

38 STULZ CyberAiR® Perimeter Cooling
STULZ Perimeter Cooling Units DX CRAC’s and CW CRAH’s Down-flow and Up-flow Down-flow with front discharge Broadest range of cooling capacities Highest capacity CRAH’s on the market (up to 60,000CFM) STULZ 730 CRAH with 10 EC Fans and filter plenum STULZ 280 CRAH with front discharge CRAC CRAH Dual Circuit DX Systems Single & Dual Circuit CW Systems kW 21 – 105 60 – 730 MBH 72 – 360 202 – 2,570 Tons 6 – 30 16 – 214 CFM 900 – 15,000 4,800 – 60,000

39 STULZ CyberAiR® Perimeter Cooling
Common Features V-Frame now for both DX (CRAC) Evaporator and CW (CRAH) Chilled Water Coils Optimal capacity and energy efficiency by providing optimized draw-through air pattern and reduced air-side pressure drop (over A-frame coils) Optional Configurations Multiple upflow & downflow air patterns available Front or rear discharge units available (ideal for slab floors) Multiple floor stand configurations available (including seismic requirements) Water-side economizer with dual coil applications (DX/CW or CW/CW) Optional Features Integral steam canister humidifier with various capacities and proportional control option Provide seamless control of external ultrasonic or other adiabatic humidification systems Air-side economizer with vertical or horizontal mixing box Hot water and low pressure steam reheat using an external heating medium Electric reheat - multi-stage low watt density, electric resistance heaters

40 STULZ CyberAiR® Perimeter Cooling
CRAC Features Highly efficient and reliable low noise scroll compressors Single or multi-stage compressor arrangement including tandem configurations Multiple stages of DX cooling to match load requirement Micro Plate Heat Exchangers for efficient heat transfer Optimized AWS/Free-cooling coils to closely match DX cooling capacities, increasing energy savings opportunities Refrigeration-based dehumidification system effectively removes excess moisture Hot gas reheat - provides reheat using recycled compressor heat Snap acting / full floating hot gas bypass system provides cooling capacity modulation and evaporator coil freeze protection Electronic Expansion Valves can be optimized to work over a wide range of conditions

41 STULZ CyberAiR® Perimeter Cooling
CRAH Features Largest capacity perimeter CW units in the industry (up to 60,000 CFM) Multiple EC Fan options (additional fans in same cabinet footprint) All EC Fans mounted in the cabinet meet full performance without having to be dropped into the raised floor (due to geometry with CW V-coil) Fewer units at higher capacity can significantly reduce capital cost & operating cost 2 x CW Valves standard on CFD-510 and larger units (option for 1 CW valve) Dehumidification efficiently achieved through reduced air volume at max cooling Standard and Seismic Floor Stands available for all CW units Filter Plenums designed with increased surface area for filtration, lower pressure drop, and improved energy savings Standard MERV 8 filters (optional up to MERV 14 filters) 100% Front Access on all sizes

42 Additional CW & DX Perimeter Cooling
Other CW & DX Cooling Products from STULZ STULZ Mini-Space STULZ FLAiR STULZ CyberONE EC STULZ ModulAiR CW & DX DX (Air, Water, Glycol Cooled) Minimal Floor Space Console DX Single Circuit DX Modular Dual Circuit DX kW 3 – 25 5 – 18 7 – 35 24 – 105 MBH 12 – 84 18 – 60 24 – 120 84 – 360 Tons 1 – 7 1.5 – 5 2 – 10 7 – 30 CFM 1,180 – 4,130 750 – 2,300 1,000 – 4,800 1,800 – 14,400

43 Why STULZ technology and design is better than the others!
Superior Components for Capacity and Efficiency EC FAN (backward curved plenum fan with Electronically Commutated motor) Why STULZ technology and design is better than the others! Fans designed to operate at reduced speed to maximize efficiency Fully scalable air volume Superior efficiency as compared to forward curved fans Over 20% immediate energy savings Over 60% energy savings when running at partial load Optimized under-floor pressure and balanced air flow Low vibration; no belt dust Maintenance free STULZ was the first to bring EC Fan technology to the U.S. market and still leads by matching with V-coils and independent control from CW valve with STULZ E2 controller!

44 Why STULZ technology and design is better than the others!
Superior Components for Capacity and Efficiency V-Frame Coils V-Frame Evaporator Coils (CRAC) V-Frame Chilled Water Coils (CRAH) Why STULZ technology and design is better than the others! Minimizes the possibility of water carryover Reduced air-side pressure drop verses A-Frame coil Provides optimal draw-through air pattern for uniform air distribution Constructed for maximum heat transfer with minimal water-side pressure drop (CRAH) DX refrigerant flow is controlled by electronic expansion valves (CRAC) STULZ was the first to bring V-coil technology to the U.S. market and still leads by matching with EC Fans and independent control from CW valve with STULZ E2 controller!

45 Heat Rejection – Air Cooled
Common features for Standard and MicroChannel Air Cooled Condensers Direct-driven high performance axial fans AC and EC Fan motors Integrated control box with main disconnect and motor protection Various fan speed control options based on refrigerant pressure R-407c & R-410a rated Low ambient temperature control options MicroChannel Condensers (SCS - MC) MicroChannel coil design: better heat rejection with smaller footprint and improved SCOP Lower weight than traditional design Uses less refrigerant Integrated receiver skid

46 Heat Rejection – Liquid Cooled
Glycol System Remote Drycooler Direct-driven high performance axial fans AC and EC Fan motor Integrated control box with main disconnect and motor protection Free cooling dry coolers are available for the entire product line Glycol System Pump Packages Single and dual pump package with redundant pumps Individually powered or powered from Drycooler

47 STULZ CyberRow® Row Cooling
Ideal for high density cooling in open or contained systems Provides for targeted hot spot reduction New models with VFD Compressor and Micro-Channel Evaporator Coil New model with additional FC Coil STULZ CyberRow CW DX CRS-090 12” CRS-180 24” CRS-042 CRS-084 CRS ”* CRS ”** kW 13 – 37 31 – 75 16 31 33 MBH 44 – 126 106 – 256 55 106 112 Tons 4 – 11 9 – 21 5 9 9.3 CFM 2,900 5,800 1,500 * VFD Compressor & Micro-Channel Evaporator ** VFD Compressor, Micro-Channel Evaporator, and additional FC Coil

48 STULZ CyberRow® Row Cooling
Common Features & Benefits Performance: Widest range of units with the largest cooling capacity in the industry EC fans provide adjustable air volume based on real time cooling requirements at the lowest energy consumption Flexible: Adapts to all major manufacturers racks and rack containment systems Installation on non-raised or raised floors Suitable for new and existing data centers; easy to add units as you grow Used in containment, open architecture, and hot spot reduction applications Top or bottom pipe and power connections 100% serviceable through front and rear access DX with Free Cooling (FC) Coil available in 24” cabinet Cold Air Discharge Cold air discharge options: front or side discharge available Front discharge recommended for containment configurations Side discharge recommended for open architecture configurations Controls Various fan control options allowing optimized air distribution Dual power with true auto switch-over function (all CW and 24” DX)

49 STULZ CyberRow® Row Cooling
Unit-Specific Features & Benefits Chilled Water (CW) 2-way or 3-way CW control valves Low water-side pressure drop Direct Expansion (DX) DX systems provided with high efficiency, highly reliable, low noise scroll compressors DX systems available with VFD Compressor and Micro-Channel evaporator (available on CRS-090 and CRS-091) DX systems are available with free cooling option (available on CRS-091) Capacity control utilizing electronic hot gas bypass with electronic expansion valves R-410a refrigerant Heat rejection with air, water, or glycol cooled condensers for the entire product range Economizer CRS-091 includes FC coil for water-side economizer (DX/CW or CW/CW)

50 STULZ CeilAiR® Ceiling Cooling
Ceiling mounted air conditioners provide precision temperature and humidity control The most complete line of ceiling mounted cooling products in the industry The ultimate space saver STULZ CeilAiR CW & DX kW MBH 12 – 120 Tons 1 – 10 CFM 500 – 4,400

51 STULZ CeilAiR® Ceiling Cooling
Common Features & Benefits Performance Wide range of options with DX or CW for precision cooling High static blowers are available for ducted systems Condensate pumps can be factory or field installed (in some models) Flexible High efficiency EC Fans available as option in certain units Fully accessible in-place through easily removable side access panels Smaller capacity units easily mounted in a standard 2’ x 4’ grid dropped ceiling plenum Spot cooler and ducted configuration Available with same-face / one-sided / L-shaped air pattern Available with low profile for limited installation height Dependable Aluminum cabinet construction for no corrosion / low weight Thermal insulation provided Controls Variety of controls from electromechanical to state of the art E2 microprocessor, allowing seamless integration with all BMS platforms

52 STULZ CeilAiR® Ceiling Cooling
Unit-Specific Features & Benefits Chilled Water (CW) Proportional controls 2-way or 3-way water / glycol control valves High pressure chilled water valves Direct Expansion (DX) DX systems with independently circuited, high efficiency, high reliability, and low noise scroll compressors Heat rejection: air cooled self-contained, air cooled split, or water / glycol cooled Refrigerant R-407c or 410a Single and dual stage refrigerant circuits with interlaced coils Economizer Water-side economizer with free cooling or alternate water source

53 DRH – Direct Room Humidifier DAH – Ducted Air Humidifier
STULZ Ultrasonic Humidifier STULZ Ultrasonic Humidifier State-of-the-art humidification for mission critical applications and any environment where clean, efficient, and precise humidity control is required 93% energy savings over steam humidifiers With integrated controls and water treatment systems Applications Data Centers / Telecomm Libraries / Museums High Tech Manufacturing Printing / Distribution Food & Beverage Agriculture / Tobacco Health Care Facilities Laboratories Commercial Offices DRH – Direct Room Humidifier Unit DAH – Ducted Air Humidifier Module DRH – Direct Room Humidifier DAH – Ducted Air Humidifier Wall or Shelf Mounted Unit Duct & Air Handling Mounted Module lbs. / hr. 4.4 – 17.6 5.3 – 39.6 kg / hr. 2.0 – 8.0 2.4 – 18.0

54 STULZ Water Treatment for Ultrasonic Humidifier
STULZ water Treatment Systems STULZ Demi-Cabinet STULZ Demi-Cabinet Enclosures For unitary RO and/or DI Applied to small capacity and light commercial humidifier applications STULZ Skid Mount RO/DI STULZ High Purity Reverse Osmosis (RO) plant pre-conditioner - by Culligan For large capacity humidifier applications CHP-250 to 8000 GPD RO/DI packages include prefiltration, storage, repressurization, UV sterilization, monitoring, and start-up

55 STULZ Ultrasonic Humidifier
Mounts below the ceiling in a conditioned space On wall or column with factory furnished mounts Suspended from above in open space Integral blower and washable filter Absorption distance determined by RH of room DRH – Direct Room Humidifier

56 STULZ Ultrasonic Humidifier
Mounts in moving air stream of AHU or ductwork Multiple humidifiers assembled on factory rack system Air velocity design similar to heating/cooling coils Factory accessories for optimized airflow and mist control Absorption distance determined by RH of airstream DAH – Ducted Air Humidifier

57 STULZ Ultrasonic Humidifier
Features & Benefits Design Multiple piezoelectric transducers immersed in water bed impart high frequency oscillation Distributed power to the piezoelectric transducers is 48 Volts AC or DC Alternating pressure and vacuum causes cavitation and production of very fine water mist Average 1 micron diameter water droplets evaporate quickly in air stream Wetted surfaces constructed of non-corrosive materials: plastic and stainless steel Internal humidifier safeties: low and high water level switches and high temperature cutout Performance Adiabatic humidification process < 10% of the energy required to boil water into steam Additional benefit of evaporative cooling - improves efficiency data centers Includes mixed bed deionization water treatment systems by Culligan 100% of the demineralized water in the humidifier utilized; does not require a flush cycle Extremely low operational expense equates to very short term ROI Controls STULZ Ultra-Series Proportional controls for single or multiple humidifier systems STULZ E² Controller for integrated operation of up to 16 humidifiers per zone Ultra-Series control boxes providing power and control distribution (up to 8 PSU’s each) Proportional analog output converted to Pulse Width Modulation at humidifiers Monitors and communicates various system functions and alarms including water quality via integrated control and/or optional BMS

58 STULZ CyberMOD – EC Fan Retrofit
Easy-to-install, variable speed EC Fan Retrofit Kit Replaces belt drive DWDI blowers for clean, efficient upgrade to legacy mission critical CRAHs & CRACs Applies to: Liebert Data Aire Comp-Aire Airflow ATS 20-60%* Fan energy savings *Savings estimate is derived from actual performance test results of (1) Liebert model FH740C with 10 hp forward curved centrifugal fan vs.. (1) Liebert model FH740C modified with the STULZ EC Fan retrofit kit, against 0.3” of external static pressure. Results may vary.

59 STULZ CyberMOD – EC Fan Retrofit
Performance Energy-saving advantages: 20% by replacing the fans only - at full flow Up to 60% when allowing additional control options, partial load operation EC Fans operate at lower speeds, lower energy, even airflow Fast ROI - typically within 2-4 years and qualifies for utility rebates EC Fans consume less energy, therefore higher net cooling capacity EC Fans provide optimized under-floor pressure and balanced airflow EC Fan 20-60%* Fan energy savings

60 STULZ CyberMOD – EC Fan Retrofit
Features & Benefits Applications Extend the life and improves efficiency and reliability of existing systems 2- and 3-fan configurations available No changes required to the primary electric or piping Design Welded aluminum construction Provides superior air distribution Built-in fan redundancy Easy installation Operation Quiet Operation (low vibration, no inverter whine) Low maintenance (no belts to adjust, no belt dust, no greasing) Controls STULZ E² controller ties directly to or replaces existing controller Fan speed control is independent of CW valve control operation Update existing control options (under-floor pressure control; return or supply air temperature control; independent fan and valve control) Communicates with BMS - optional

61 STULZ Replacement CRAH
40-60%* Total energy savings STULZ Replacement CRAH Direct drop-in chilled water, high capacity CRAH replaces inefficient legacy units Provides instant energy savings and improved performance Applies to: Liebert FH 422C Liebert FH 529C Liebert FH 600C Liebert FH 740C STULZ Replacement CRAH CW kW 76 – 124 MBH 261,000 – 423,000 Tons 21 – 35 CFM 12,500 – 18,600 *Savings estimate is derived from actual performance test results of (1) STULZ CCD-1805 CWE-LR vs.. (1) Liebert model FH740C, at 16,500 cfm, against 0.3” of external static pressure. Results may vary.

62 STULZ Replacement CRAH
Features & Benefits Application All the benefits of STULZ Perimeter Cooling for Mission Critical Design STULZ cabinet and unique design features allow a direct drop-in replacement No modification to existing piping mains, primary electric, or floor stand Performance STULZ V-Coil arrangement Energy savings advantages: Up to 40% simply by replacing the CRAH Savings of 50% and beyond can be achieved using advanced controls EC Fans can provide Increased air volume at maximum fan speed EC Fans typically operate at lower speeds, lower energy, even airflow EC Fans consume less energy, therefore higher net cooling capacity EC Fans provide optimized under-floor pressure and balanced airflow Fast ROI; qualifies for utility rebates Control The STULZ E² controller allows communication with all major BMS/BAS systems Update existing control options (under-floor pressure control; return or supply air temperature control; independent fan and valve control)

63 STULZ E2 Controller Retrofit
STULZ E2 Controller retrofit kit and authorized installation services For legacy STULZ chilled water units with C6000 controllers and select competitor units STULZ E2 controllers can be quickly retrofitted An excellent way to unify disparate controller platforms and gain tighter control by adding dew point control / under-floor static pressure capabilities Improves BMS communications by eliminating outdated and unnecessary gateways while increasing read/write capability Large Bezel with Touchscreen Microprocessor

64 STULZ Product Support STULZ Product Support
Comprehensive Service to ensure customers maximum efficiency and reliability STULZ Product Support consists of four teams dedicated to post-sale support: • Technical Support – Phone support for warranty parts/labor authorization and troubleshooting • Field Service – Dispatch/coordination of authorized technicians for: start-up, PM, break fix, onsite retrofit & refurbishment projects. • Parts – Factory authorized Part sales • Training – Technician & Owner Training Planned Service Preventative Maintenance Contracts Multiple options for Factory Authorized Preventative Maintenance contracts. An Authorized STULZ PM contract guarantees response by qualified technicians when emergency repairs are necessary.

65 STULZ Product Support Deployment Services
Factory Authorized Warranty Inspection/Start-up Industry leading Two Year Parts and 90 Day Labor Warranty with a Warranty Inspection/Start-up. Factory Authorized technicians ensure that STULZ equipment has been installed per factory guidelines and identify any deficiencies prior to warranty validation. Basic Product Familiarization Factory Authorized technicians provide a brief equipment overview. BMS/Communication Services Factory Authorized technicians ensure that STULZ products are configured and capable of communicating in accordance with customer requirements. Commissioning Assistance Factory Authorized technicians provide a factory interface to agents during commissioning, functional and integrated testing. Owner Training Comprehensive and flexible training programs for end users via onsite, factory or web-based sessions. Tailored to the customer’s schedule, equipment and facility requirements.

66 STULZ Product Support STULZ Product Support Network (PSN)
A comprehensive network of Factory Technicians and Certified Service Partners throughout North America All technicians and partners are pre-qualified, trained, and certified by STULZ at our factory Over 90 locations to actively support end users and contractors

67 STULZ Global Presence Globally Close To You
100’s of STULZ sales and service offices around the globe Engineering and Production Locations: U.S.A. - Germany - Italy - India - China