Download presentation
Presentation is loading. Please wait.
Published byJeremy Webster Modified over 9 years ago
1
Breathing Air Scott-RevolveAir Charge station with X4 controller. Storage Auto-fill capable. Unit can fill 2 SCBA bottles at a time behind a burst shield. Scott- Hush 15 hp Multi stage, 23.5 cfm Compressor. 480v 3 phase Motor in the Starboard VSP room. 6000 psi system. Bank of 4 DOT/ASME Air Storage Tanks located near the compressor in the Starboard VSP room. Not a Cascade sys. A Crossover Air Control/Regulator panel (High to Low) for Emergency air needs. Circuit Breaker located in Main Electrical Panel under MCC control panel. www.scottsafety.com
2
Breathing Air Components Scott-Hush model. 15 hp 23.5 cfm Compressor Unit Low Oil sensor Oil Fill/Dipstick 5 Quarts of I/R XL-700 Compressor Oil.
3
Breathing Air Components 480v 3ph 15hp Motor Hinge Point Note: The Vee-belts are tensioned by the Weight of the Motor bearing down on the drive pulleys.
4
Breathing Air Components The Compressor Circuit Control Box. The E-Stop was added for a Lock-Out to protect the safety of any service personnel.
5
Breathing Air Components Multistage Pressure Gages Every 15 minutes of operation the dump valve will open and the condensation will be forced into two collection jars and ultimately into the reservoir. When this happens you will see a momentary drop in pressure on the 2-3-4 stage’s pressure gages. Normal.
6
Breathing Air Components Compressor Output Pressure Gage
7
Breathing Air Components Condensation Collection Jars Condensation Reservoir The Compressor will cycle during its operation to remove condensation. You will notice a pressure Drop in the 3 higher stages. This is Normal.
8
Breathing Air Components Condensation Collection Jars and Reservoir
9
Breathing Air Components Purification Filters are located behind the unit. A little tight in this location.
10
Breathing Air Components Intake Air Cleaner Each Stage has a Pressure Relief Valve
11
Breathing Air Components Bank of 4-Air Storage Bottles Located in the Starboard VSP room. System likes to fill one bottle at a time. Two more forward
12
Breathing Air Components RevolveAir with X4 Controlled Charge Station
13
Breathing Air Safety Tip: Watch your fingers here as you rotate the cylinders in and out. Definite Pinch Point.
14
Breathing Air Components SCBA Bottles simply thread into this fitting and hang free on the SCBAs valve body. When removing a filled bottle this is your pressure drain valve to free up the threads. There is 1 adapter hose for filling SCUBA tanks
15
Breathing Air Good Look at the Revolving Door Fill Station. Do not forget to close your Bleed valve before you rotate it close. If you do forget, you will hear it Immediately after you push down the lock/unlock lever. This locking Lever also controls an internal air fill valve.
16
Breathing Air Components Control Panel
17
Breathing Air Control Screen
18
Breathing Air Air Sources: Compressor or the Bank of Cylinders
19
Breathing Air Set your Bottle Fill Pressure Here Open/Close Fill Valve Bottle Pressure
20
Breathing Air Cross-Over Control Box Forward Starboard ER bulkhead Just to the Starboard side of the service air compressors. On/Off Isolation/ Flow Control Valves Pressure Regulator and Outlet Pressure Gage. Hi pressure Low Pressure
21
Breathing Air The X4 Control Screen functions are being sent to Mike Lorton. They are copies of the Scott manual pertaining to its functions. He will post them with this Power Point. They are much better explained than by me. Easy system to use. The Compressor is relatively quit. Note: Before we begin to fill bottles the VSP room Ventilator Fan must be turned on and BOTH ventilation Vent hatches opened. (intake and exhaust) Located P&S at the Main deck Doorways.