Detection methods for long-lived particles at the LHC S. Viganò, A. De Min Università di Milano Bicocca
2
IFAE, 2006-04-19S. Viganò2 Outline Introduction Detection of heavy stable charged particles: Detection of non-pointing photons: Conclusions TOF measurement in muon chambers dE/dx in the tracker and in ECAL From shower shape in the e.m. Calorimeter From late showers in the muon system TOF measurement in the e.m. Calorimeter From ECAL + HCAL
3
IFAE, 2006-04-19S. Viganò3 Introduction Massive long-lived particles are expected in several models beyond SM, for examples : Models with a weakly broken symmetry, where the particle would be stable if the symmetry were exact → for ex. SUSY models with tiny RPV Models with an exact symmetry which forbids the decay of heavy exotics into ordinary particles, where the decay into neutral particle is suppressed by small coupling or by phase space → for ex. SUSY models with exact RP where the gravitino is the LSP or some other ‘hidden sector’ particle → or pseudo-Higgs models with an absolutely stable neutral pseudo-Higgs and a possible very small mass gap to the lightest charged one In this talk we focus on the second class of models and, in particular, on SUSY model with gauge-mediated SUSY breaking (GMSB)
4
IFAE, 2006-04-19S. Viganò4 GMSB scenario SUSY breaking Hidden sector N gauge singlets of SU(5) Messenger sector MSSM Visible sector Λ : effective scale of the breaking M : messenger mass scale Mass spectrum depends on 5 parameters: N, M, Λ, tanβ, sign(μ) Gravitino is the Lightest Supersymmetric Particle and has couplings inversely proportional to its mass. For masses > 1 eV/c 2 decay into LSP has long lifetime.
5
IFAE, 2006-04-19S. Viganò5 NLSP Gravitino: light and non- interacting GMSB phenomenology defined by Next to Lightest Supersymmetric Particle NLSP is not univocally determined but depends on GMSB parameters 2 candidates: The lightest slepton -> Stau The lightest Neutralino
6
IFAE, 2006-04-19S. Viganò6 Experimental possibilities NLSP decays into its SM partner and gravitino with: From the experimental point of view there are 3 possibilities: c large compared to detector dimensions c of the order of detector dimensions c small w.r.t. detector dimensions 1. Stau NLSP looks like a heavy muon 2. Neutralino will escape detection Both types of NLSP can decay inside the detector and lifetime can be directly measured All NLSP decay inside the detector
7
IFAE, 2006-04-19S. Viganò7 Stable stau signature Long-lived stau differs from muons by considerably lower main observables useful to distinguish between the 2 cases: Time of flight Specific ionization Muon chambers Tracker and/or e.m. calorimeter
8
IFAE, 2006-04-19S. Viganò8 CMS muon system: 4 muon stations in between the iron yoke slabs Geometric coverage: up to | |<2.1 Each barrel muon station (MS) equipped with Drift Tubes (DT) 12 layers grouped in 3 superlayers per station: 2 for RΦ measurement 1 for z( ) measurement (0 in the outermost chamber) Precise tracking with spatial resolution of the order of 75÷150 m per tracking point CMS muon chambers: layout
9
IFAE, 2006-04-19S. Viganò9 TOF measurement =1 <1 Position of a particle determined from the drift time of electrons to anode wires A starting time t 0 (time of flight from the production point to the measuring station) is needed For the stau: t 0 is a free parameter function of is measured in order to minimize χ 2 of the reconstructed track If =1 is assumed in the case of stable stau, points would not align! Time resolution: 1ns (both ATLAS and CMS) CMS
10
IFAE, 2006-04-19S. Viganò10 Mass and lifetime determination Squared mass of the particle determined from the 1/ measurement Unquestionable signal significance even after 500 pb -1 (1 week @ 10 33 cm -2 s -1 ) In each event a couple of NLSP is produced ⇒ lifetime can be inferred by the ratio N 1 /N 2, since it holds: CMS ATLAS Precision after 30 fb -1 :
11
IFAE, 2006-04-19S. Viganò11 HSCP from dE/dx (CMS) The measurement of specific ionization is a complementary approach Precise dE/dx only from tracker could be difficult because: Information from the ECAL can be useful because: 1.High density of low momentum tracks (min bias) 2.Limited resolution (7-10%) 3.Limited dynamic range in the readout 4.Saturation effects 1.Cleaner environment 2.More gaussian distribution of dE/dx 3.Sensitive to particles that don’t reach the muon chambers for which no TOF is available
12
IFAE, 2006-04-19S. Viganò12 Kinematics
13
IFAE, 2006-04-19S. Viganò13 HSCP in the CMS ECAL ECAL can provide non-negligible information on dE/dx Its performance on particles which do not shower has been studied in the context of calibration with cosmic rays → very promising results MIPs deposit 11 MeV/cm in PbWO 4 → 250 MeV if they pass through a single crystal If the tracker is used to determined which crystal is traversed the resolution (considering 40 MeV RMS noise per channel) is: 1.16% at 250 MeV (1 m.i.p. equivalent) 2.4% at 1 GeV (4 m.i.p. equivalent) 3.2% at 5 GeV (20 m.i.p. equivalent) GeV # Entries Pedestal mip Cosmics Pions 1 ADC count = 8.4 MeV
14
IFAE, 2006-04-19S. Viganò14 Neutralino decays When the neutralino c is of the order of the detector dimensions (which correspond to gravitino mass in the range 1-100 eV) its decay occurs in the tracker volume and the experimental signature is missing energy (carried by the 2 gravitinos of the event) and 2 high energy photons which don’t point to the interaction vertex With the electromagnetic calorimeter either in ATLAS or in CMS it is possible to determine the photon impact direction and hence to give information on neutralino lifetime
15
IFAE, 2006-04-19S. Viganò15 Impact direction reconstruction The ATLAS e.m. calorimeter is segmented longitudinally so it can provide directional information In his first compartment it has narrow strips that give good resolution in In the barrel: Efficiency to detect an isolated photon as non-pointing as a function of the significance: i.e. Requiring to be non-zero by 5 gives an efficiency of 82% ATLAS
16
IFAE, 2006-04-19S. Viganò16 Shower shape of non pointing photons CMS ECAL not longitudinally segmented The impact direction of the photon can be inferred from the asymmetry in the shape of the energy deposition among the crystals The difference between the length of the two axes A1 and A2 is a good variable to quantify the degree of tilt of non pointing particles is the degree of asymmetry of the shadow (relative difference between the size of the shadow along and the direction perpendicular to it) Rejection of pointing photons can be performed at a level of 99% keeping an acceptance for the signal photons bigger than 0.8 (for =0.4 rad = 23°) for different tilts
17
IFAE, 2006-04-19S. Viganò17 Photon direction from ECAL+HCAL Alternatively, use ECAL-HCAL lever arm to determine photon direction. Three difficulties: 1)Limited space granularity 2)Need photon leakage in HCAL, so sensitive for high-energy showers (and high-energy neutralinos) 3)But photon energy ( Neutralino energy) negatively correlated with photon angle (high-energy Neutralinos produce collinear photons!) c =0 cm c =500 cm
18
IFAE, 2006-04-19S. Viganò18 TOF measurement If the mass and the momentum distributions of the neutralinos are determined from other measurements it is possible to convert the rate into a lifetime measurement Photons from neutralino decaying into gravitino are delayed w.r.t. prompt photons due to the geometry of their path and to the velocity of the neutralino Mean delay of non-pointing photons of the order of 2 ns ATLAS e.m. calorimeter has a time resolution of about 100 ps CMS ECAL better than 1 ns for signal amplitudes greater than 2 GeV (ultimate precision determined by constant term ~ 0.1 ns) ⇒ Independent way to detect photons from neutralino decays CMS ATLAS
19
IFAE, 2006-04-19S. Viganò19 Late shower development When neutralino c is in the range 1÷100 m a large fraction of decays take place inside the muon detector. Photon inside the iron yoke develops an e.m. showers Showers can leak to the muon station ⇒ Muon chambers should register from a few tens to few hundreds of hits Measured flight path (distance between interaction point and the entrance point to the muon station which is supposed to see the accumulation of hits) depends on neutralino lifetime This method starts to be sensitive at c ~20 cm Maximal acceptance at c ~10 m CMS
20
IFAE, 2006-04-19S. Viganò20 Conclusions We have shown that both ATLAS and CMS have sensitivity to massive long-lived particles (such as staus or neutralinos in GMSB models) through direct detection or through their decay products Most techniques require some “improper” use of detectors: –Timing information from calorimeters and muon detectors –Showers in muon stations –Asymmetries in shower shapes In some cases also the decay lifetime can be measured with a good accuracy (which in GMSB would allow the computation of the SUSY breaking scale F 1/2 )
21
IFAE, 2006-04-19S. Viganò21 References Measurement of the time of flight of stable stau: –CMS CR 1999-019, M. Kazana, G. Wrochna, and P. Zalewski –Hep-ph/0012192, S. Ambrosiano, B. Mele et al. HSCP in the CMS ECAL: –CMS NOTE 2005-023, M. Bonesini, T. Camporesi et al. –C. Marchica, talk @ ECAL TB meeting July 13th 2005 Neutralino decays into non-pointing photons: –ATLAS Physics TDR (chapter 20) –G. Franzoni PhD Thesis (The CMS electromagnetic calorimeter and its sensitivity to non pointing photons) –CMS CR 1999-019, M. Kazana, G. Wrochna, and P. Zalewski –F. Tartarelli, talk @ HEP 2005 ( Final test beam results from ATLAS electromagnetic calorimeter series modules) –CMS NOTE 2006-037, R. Bruneliere and A. Zabi