Download presentation
Presentation is loading. Please wait.
Published byWinfred Nicholson Modified over 9 years ago
1
Technology Transition Workshop FIDO Program Training Elements and Validation Study Technology Transition Workshop| Joan Ring and Kirk Grates
2
Technology Transition Workshop Personnel Requirements Trainer Requirements − Trained operational drug chemist from a forensic laboratory − Experience using field test kits − Familiar with the training program − Flexible schedule (organization of program, document maintenance, case review, answering questions) − Excellent verbal and written communication skills FIDO Program Technology Transition Workshop FIDO Program Training Elements and Validation Study 2
3
Technology Transition Workshop Personnel Requirements Law Enforcement Officer − Certified LEO − 3 to 5 years as a LEO − Strong record of arrests/drug arrests − Willingness to test other officer’s evidence − Excellent verbal and written communication skills − Excellent courtroom skills − Cannot be color blind FIDO Program Technology Transition Workshop 3 FIDO Program Training Elements and Validation Study
4
Technology Transition Workshop Performance Standards Demonstrate competency and accuracy − Recommended grade for written exam is 80% − 100% is required on practical assessments FIDO Program Technology Transition Workshop 4 ©CrystalGraphics™ FIDO Program Training Elements and Validation Study
5
Technology Transition Workshop Evidence Control FIDO program policies and procedures must insure the integrity of the evidence All submitted evidence must meet agency-specific packaging, marking and sealing guidelines Document chain of custody Request for Field Drug Test form (provided on CD) FIDO Program Technology Transition Workshop 5 FIDO Program Training Elements and Validation Study
6
Technology Transition Workshop Report Format Example provided on CD Heading − Date of report − Investigating officer, agency name and address − Agency case number − Field testing number (unique identifier) FIDO Program Technology Transition Workshop 6 FIDO Program Training Elements and Validation Study
7
Technology Transition Workshop Report Format Body − Suspect information − Description of item(s) submitted − Field testing officer certification − Examination results FIDO Program Technology Transition Workshop 7 FIDO Program Training Elements and Validation Study
8
Technology Transition Workshop Report Format Closing − Testing officer name and title − Field test file number − Date and time of field test − Reporting officer name and signature FIDO Program Technology Transition Workshop 8 FIDO Program Training Elements and Validation Study
9
Technology Transition Workshop Quality Control Report Review − Technical Review notes, data, pictures Example form on CD − Administrative Editorial accuracy Laboratory re-analysis of 10% of cases per quarter per officer FIDO officers undergo annual recertification FIDO Program Technology Transition Workshop 9 FIDO Program Training Elements and Validation Study
10
Technology Transition Workshop FIDO Instructional Content Class outlines Certification lesson plans Recertification class lesson plans Class lecture and presentation content Practical exercises Written examinations Practical assessments Training completion record FIDO Program Technology Transition Workshop 10 FIDO Program Training Elements and Validation Study
11
Technology Transition Workshop Validation Study of Color Test Kits The validation study was designed and conducted to address the following criteria: − Adequate sensitivity to allow the detection of drugs at concentrations commonly encountered in street samples − Sufficient specificity to minimize false positive or false negative interpretation − Accurate results for drugs mixed with a variety of adulterants − Reproducible results FIDO Program Technology Transition Workshop 11 FIDO Program Training Elements and Validation Study
12
Technology Transition Workshop Environmental Conditions Test kit performance was assessed after kits were subjected to one of the following environmental conditions for two weeks: − Frozen (-3 o C to -17 o C) − Refrigerated (2 o C to 5 o C) − Oven (Dry Heat) (40 o C) − Trunk of vehicle (Moist Heat) (≈20 o C to 38 o C) FIDO Program Technology Transition Workshop 12 FIDO Program Training Elements and Validation Study
13
Technology Transition Workshop Brands of Kits Tested NarcoPouch ® nik® NARK® QuickCheck™ FIDO Program Technology Transition Workshop 13 FIDO Program Training Elements and Validation Study
14
Technology Transition Workshop Types of Kits Tested Scott's Reagent (modified) Marquis Reagent Methamphetamine/MDMA reagent Mecke's Reagent FIDO Program Technology Transition Workshop 14 FIDO Program Training Elements and Validation Study
15
Technology Transition Workshop Sample Preparation Samples were prepared by combining pure drug standards with pure cutting agents in the following ratios (w/w): − 5:95 − 10:90 − 20:80 − 30:70 − 40:60 − 50:50 − 60:40 − 80:20 FIDO Program Technology Transition Workshop 15 FIDO Program Training Elements and Validation Study
16
Technology Transition Workshop Samples Cocaine HCl − Boric Acid − Caffeine − Mannitol − Procaine FIDO Program Technology Transition Workshop 16 FIDO Program Training Elements and Validation Study
17
Technology Transition Workshop Samples Cocaine Base − Benzocaine − Caffeine − Mannitol FIDO Program Technology Transition Workshop 17 FIDO Program Training Elements and Validation Study
18
Technology Transition Workshop Samples Methamphetamine HCl − Caffeine − Dimethylsulfone (DMS) − Niacinamide FIDO Program Technology Transition Workshop 18 FIDO Program Training Elements and Validation Study
19
Technology Transition Workshop Samples Heroin − Caffeine − Procaine − Quinine FIDO Program Technology Transition Workshop 19 FIDO Program Training Elements and Validation Study
20
Technology Transition Workshop Testing Method Three milligram portions of sample were weighed out in duplicate using an analytical balance Each three milligram portion was placed into an appropriately labeled test kit for evaluation Ampoules were broken according to the procedure provided by each manufacturer FIDO Program Technology Transition Workshop 20 FIDO Program Training Elements and Validation Study
21
Technology Transition Workshop Testing Method After 60 seconds, the color, if one developed, was matched to a chip in the Munsell Book of Color − Color chips from the Munsell Book of Color were viewed at angles between 40-50 o under General Electric Watt-Miser II F40LW-RS-WMII Lite White 34 Watt fluorescent bulbs − The hue, value and chroma were recorded FIDO Program Technology Transition Workshop 21 FIDO Program Training Elements and Validation Study
22
Technology Transition Workshop Munsell Color Chips FIDO Program Technology Transition Workshop 22 FIDO Program Training Elements and Validation Study
23
Technology Transition Workshop Conclusion All four brands of test kits are appropriate for use in a FIDO program as presumptive tests for the presence of cocaine, methamphetamine, and heroin with the following limitations… FIDO Program Technology Transition Workshop 23 FIDO Program Training Elements and Validation Study
24
Technology Transition Workshop Limitations Field drug test kits are presumptive in nature They do not provide any structural information and are subject to false positives Therefore, all samples producing a negative or ambiguous presumptive result should be sent to a forensic laboratory for a complete analysis FIDO Program Technology Transition Workshop 24 FIDO Program Training Elements and Validation Study
25
Technology Transition Workshop Limitations Kits should not be used for the analysis of residues Kits should not be used on liquid samples Color interpretation is subjective, especially when analyte concentrations approach the detection limit or when an interfering compound is present FIDO Program Technology Transition Workshop 25 FIDO Program Training Elements and Validation Study
26
Technology Transition Workshop Limitations Kits must be stored in environmental conditions that will not affect the integrity of the test kit or its components Kits should not be utilized past the manufacturer’s recommended shelf life Use of the Cocaine test kit to distinguish between cocaine salt and base is problematic; it is not recommended to employ field test kits for this purpose FIDO Program Technology Transition Workshop 26 FIDO Program Training Elements and Validation Study
27
Technology Transition Workshop Contact Information Joan Ring Kirk Grates 7881 114 th Ave. N. 727-549-6067 Joan.Ring@nfstc.org Kirk.Grates@nfstc.org FIDO Program Technology Transition Workshop 27 Note: Unless otherwise indicated, all images contained within this presentation are courtesy of NFSTC. FIDO Program Training Elements and Validation Study
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.