Download presentation
Presentation is loading. Please wait.
Published byPeter Pearson Modified over 9 years ago
1
IT-100 Integration Module
2
IT-100 - Overview The IT-100 features a bi-directional RS-232 interface that accepts commands and sends event-driven or state- change commands to third-party applications, for example home automation or HVACS system.
3
IT-100 – Specifications Current Draw:65mA Compatibility:All PowerSeries Mounting:Inside control panel cabinet or PC5003 cabinet
4
Compatible with all PowerSeries control panels Bi-directional RS-232 interface Real-time zone status Fully programmable 4-wire hook-up to KEYBUS Enables third parties to perform virtual keypad functions Enables third parties to perform thermostat control functionality via the DSC Escort module IT-100 – Features
5
IT-100 – Sample Configuration
6
IT-100 – Module Overview RED, BLK, YEL, GRN: These terminals are used to connect the IT-100 to the Keybus of the control panel.
7
IT-100 – Module Overview LED: This LED is used to indicate the current status of the IT-100.
8
IT-100 – Module Overview DB9: This connection is used to wire the IT-100 to the third-party application. Note: a ‘straight-through’ RS-232 is required for this connection
9
IT-100 – Additional Wiring Information The IT-100 includes a ferrite. Ensure that it is looped through the keybus (twice) and placed as close to the IT-100 as possible.
10
IT-100 – LED Information
11
IT-100 – Baud Rate Selection Baud Rate Selection: The baud rate of the IT-100 is selectable using a third party applications (default = 9600 baud).
12
Q&A IT-100