1 | INALA TECHNOLOGIES TEST PROCEDURE: ECS2, SAM2, SAM1.5 & ACCESS VERSION 1.0.

Similar presentations


Presentation on theme: "1 | INALA TECHNOLOGIES TEST PROCEDURE: ECS2, SAM2, SAM1.5 & ACCESS VERSION 1.0."— Presentation transcript:

1 1 | INALA TECHNOLOGIES TEST PROCEDURE: ECS2, SAM2, SAM1.5 & ACCESS VERSION 1.0

2 2 | TESTING SUMMARY SAM Training 1.Set up SAM2. 2.Set up ECS2 communication controller. 3.Test communication to SAM1.5 or SAM2 unit via ECS2 coms Controller 4.Test communication to Access Control unit via ECS2 coms Controller

3 3 | SAM2 SET UP – VIA RS232

4 4 | SAM2 – RS232 SAM Training RS232 Communication Test; Connect a straight RS232 cable between the Lap Top and the SAM2 RS232 port(DB9 Connector on front panel Open SAM2 ECT Select “Com Port” and double click on “Password”

5 5 | SAM2 – SET UP VIA RS232 CONTINUED SAM Training RS232 Communication Test; Cont; Active communication will be shown on the bottom left as indicated with the RED circle until it says “received” 1.Click on “Load Config” and select the applicable config file. 2.Click on “Update SAM” and wait until SAM has been updated – This can be seen on the bottom left as indicated with the RED circle until it says “received” 3.Click on “Sync Time” 4.Click on “Get Config” and ensure that SAM2 shows you the current date and time. 5.Capture SAM2 Serial number. 6.Click on “Update” 7.Click on “Set Config”

6 6 | SAM2 – SET UP VIA RS232 CONTINUED SAM Training RS232 Communication Test; Cont; 1.Click on “Alarm Configuration” tab 2.Select “RS485” under “Coms Config” 3.Click on “Set” 4.Click on “Get Config” 5.Click on “Set Config” Check that “Intruder” alarm is number “9” Check that “Movement” alarm is number “11” Close SAM2 ECT

7 7 | ECS2 COMMUNICATION CONTROLLER SET-UP

8 8 | ECS2 COMS CONTROLLER – SET UP SAM Training ECS2 Coms Controller Set up; Connect a USB printer cable between the Lap Top and the ECS2 Coms Controller USB port. Open ECS2 ECT Select “USB” and click on “Login”

9 9 | ECS2 COMS CONTROLLER – SET UP SAM Training ECS2 Set Up: Check that the units has the latest Firmware version being “Build 1.6” If Not on latest version, upgrade to latest version 1.Click on “Upgrade to V1.6” 2.Click on “File” then “Load Config” 3.Click on “Update uniit” 4.Click on “Site Inventory”

10 10 | ECS2 COMS CONTROLLER – SET UP SAM Training ECS2 Set Up: 1.Capture ECS2 Coms Controller Serial number. 2.Click on “Update unit” 3.Click on “Configuration” Tab 4.Click on “Update unit” 5.Close ECS2 ECT

11 11 | TESTING COMMUNICATION TO THE SAM OR ACCESS CONTROL UNIT VIA THE ECS2 COMMUNICATION CONTROLLER

12 12 | SAM2 COMMUNICATION TEST VIA THE ECS2 COMMUNICATION CONTROLLER

13 13 | SAM2 – COMMUNICATION TEST VIA ECS2 COMMUNICATION CONTROLLER – “RS485” SAM Training RS485 Communication Test; Connect a USB printer cable between the Lap Top and the ECS2 communication Controller USB port Open SAM2 ECT Select “TCP” and insert 192.168.11.1 (USB IP Address) and Port 301 and double click on “Password”

14 14 | SAM2 – COMMUNICATION TEST VIA ECS2 COMMUNICATION CONTROLLER – “RS485” SAM Training RS485 Communication Test; Cont; Active communication will be shown on the bottom left as indicated with the RED circle until it says “received”

15 15 | SAM1.5 COMMUNICATION TEST VIA THE ECS2 COMMUNICATION CONTROLLER

16 16 | SAM1.5 – COMMUNICATION TEST VIA ECS2 COMMUNICATION CONTROLLER – “RS485” SAM Training RS485 Communication Test; Connect a USB printer cable between the Lap Top and the ECS2 communication Controller USB port Open SAM1.5 ECT Select “TCP” and insert 192.168.11.1 (USB IP Address) and Port 310 and double click on “Password”

17 17 | SAM1.5 – COMMUNICATION TEST VIA ECS2 COMMUNICATION CONTROLLER – “RS485” SAM Training RS485 Communication Test; Cont; Active communication will be shown on the bottom left as indicated with the RED circle until it says “received”

18 18 | ACCESS CONTROL COMMUNICATION TEST VIA THE ECS2 COMMUNICATION CONTROLLER

19 19 | ACCESS CONTROL – COMMUNICATION TEST VIA ECS2 COMMUNICATION CONTROLLER – “RS485” SAM Training RS485 Communication Test; Cont; 1.Click on “TCP” and insert IP address 192.168.11.1. 2.Click on “Connect” 3.Click on “Logon” 4.Click on “Open Door” 5.Click on “Get Version” 6.Click on “Get Time” 7.Click on “Log off” 8.Click on “Exit” Responses should be received as indicated in the Red circle