1
Making blanket data revisions using the property identifications by COLOR. TRIFLEX® WINDOWS PipingSolutions, Inc. 01 July 2004 1
2
Here we have mistakes in the wall thickness of the pipe. TRIFLEX® WINDOWS PipingSolutions, Inc. 01 July 2004 2 Notice that the light blue color shows that a different wall thickness has been entered.
3
Here we have mistakes in the Temperature for Load Case No. 1 TRIFLEX® WINDOWS PipingSolutions, Inc. 01 July 2004 3 The colors show that all the pipe is the same temperature. The pipe stanchions should not be the same temperature.
4
Here we have mistakes in the Coeff. of Expansion for Load Case No. 1 TRIFLEX® WINDOWS PipingSolutions, Inc. 01 July 2004 4 Notice that the light blue color shows that a different Coeff. of Exp. has been entered. The yellow color at the stanchions is correct. Since a different temperature should be at the stanchions.
5
Here we have mistakes in the Contents or Specific Gravity for Load Case No. 1 TRIFLEX® WINDOWS PipingSolutions, Inc. 01 July 2004 5 Notice that the light blue color shows that a different specific gravity has been entered. The light blue color at the stanchions is correct. Since a different specific gravity should be at the stanchions.
6
Now note that by careful node numbering, I have all the stanchions input after the piping system. So I can do the stanchions all at one time. TRIFLEX® WINDOWS PipingSolutions, Inc. 01 July 2004 6 Pipe size 6 inch First N.P. 5 and the Last N.P. 185 Pipe size 3 inch First end N.P. 200
7
Note how I can change all the stanchions at one time by Rippling from component line no. 38 thru component line no. 43. TRIFLEX® WINDOWS PipingSolutions, Inc. 01 July 2004 7 Ripple to component line no. 43. Ripple from component line no. 38.
8
Change the specific gravity, and insulation of all the stanchions at once. TRIFLEX® WINDOWS PipingSolutions, Inc. 01 July 2004 8 Ripple to component line no. 43.
9
Change the temperature of all the stanchions at once. TRIFLEX® WINDOWS PipingSolutions, Inc. 01 July 2004 9 Ripple to component line no. 43.
10
Here we have mistakes in the wall thickness. And we can change all the same size pipe at once. TRIFLEX® WINDOWS PipingSolutions, Inc. 01 July 2004 10
11
Change all the same size pipe at once. By rippling from component line no. 1 to component line no. 37. TRIFLEX® WINDOWS PipingSolutions, Inc. 01 July 2004 11 Ripple to component line no. 37.
12
Change all the same size pipe at once. By rippling from component line no. 1 to component line no. 37. TRIFLEX® WINDOWS PipingSolutions, Inc. 01 July 2004 12 Ripple to component line no. 37.
13
Note all the same size wall thickness for each size pipe as it should be. TRIFLEX® WINDOWS PipingSolutions, Inc. 01 July 2004 13
14
Note all the same temperature except for the stanchions which is as it should be. TRIFLEX® WINDOWS PipingSolutions, Inc. 01 July 2004 14
15
Note all the same Coeff. Of Exp. except for the stanchions which is as it should be. TRIFLEX® WINDOWS PipingSolutions, Inc. 01 July 2004 15
16
Note all the same Specific Gravity except for the stanchions which is as it should be. TRIFLEX® WINDOWS PipingSolutions, Inc. 01 July 2004 16