Presentation is loading. Please wait.

Presentation is loading. Please wait.

Compressor Replacement – ODU

Similar presentations


Presentation on theme: "Compressor Replacement – ODU"— Presentation transcript:

0 Compressor Replacement – ODU
Open the Discharge Valve to release the Refrigerant from AC completely Remove Control Board Cover plate ( 1 Screw) & Disconnect the IDU & ODU Connection. Remove the locking Screws of Top cover (8 Screw) Outdoor unit – Remove IDU & ODU Connecting pipe Accessory Remove the locking Screws of Valve Side plate (8 Screw) Remove the locking Screws of Front plate (7 Screw)

1 Compressor Replacement – ODU
Remove Control Board & its Wiring (Motor & Compressor Wiring). Take Out Control Board & Change The Capacitor AS Required Value (As per Requirement)(OLD Capacitor Mfd, new Capacitor – Mfd ) Remove the Wiring connection of compressor. Remove screw of suction valve from valve plate to remove suction tube assy. De-braze Suction & Discharge Tube. Remove Compressor Mounting Nut & Take Out the Compressor Take new Compressor For Replacement. OLD Comp – UR8B180JHCJH NEW Comp – UR8B180DUBJH Use Same Compressor Accessory to Fit The new Compressor As Shown.

2 Compressor Replacement – ODU
Braze the Discharge & Suction Tube. Fix The Suction Valve With Valve plate. Do the Compressor Wiring. Vacuum the system and Gas charge ( Qty refer to Quality Label) Check all the joints with soap solution Assemble the components in reverse order