Presentation is loading. Please wait.

Presentation is loading. Please wait.

Ready to line up with the best?

Similar presentations


Presentation on theme: "Ready to line up with the best?"— Presentation transcript:

1 Ready to line up with the best?
ITW GSE is the wold’s leading supplier of 400 Hz and Pre-Conditioned Air units Our vision: Focusing on what is important and simple , we aim at obtaining: maximum customer satisfaction Xavier CHARRONDIERE – Market Manager - GSE Specialist

2 Trilectron/Air-a-Plane
ITW GSE AXA ITW Illinois Tool Works, ITW - USA 100 years of history More than 840 decentralized business units in 58 countries More than $17,924 billion in revenues in 2012 More than employees Below companies reporting to President & CEO Mr. Scott Santi J&B Aviation USA (Trading Company) 400 Hz Power Supply PCA - Accessories AXA Power ApS Denmark Ground Power Units Pre-conditioned Air Units Hobart Ground Power USA Ground Power Units Trilectron/Air-a-Plane USA Ground Power Units Pre-conditioned Air Units ITW GSE Group UK United Kingdom Ground Power Units

3 Product Range AXA Compact solid-state GPU
AXA Power Coil 90 kVA solid-state GPU & cable coil in one single unit AXA Power Pre-conditioned air unit

4 Innovation & Product Development
2013 The AXA 2400 2012 The AXA Power Cable Retriever 2009 The AXA Power PCA 2007 The AXA 2300 Compact GPU 2005 The AXA Power Coil 2004 The AXA Twin Power 2003 The Plug & Play System 1997 The AXA 2200 GPU 1990 The AXA 2100 GPU 1987 The AXA 2000 GPU 1958 The AXA 28 VDC GPU 1924 Foundation of the company Aircraft Requirements Technological Know-How Dialogue with Users

5 References

6 AXA KVA GPU 400% Overload Unique Voltage Quality Clean Input Power AXA 90KVA GPU with Cable Coil in one enclosure

7 Future proof your operations
The AXA 2400 unit is anticipated the future 400% overload ! Powers all types of aircraft incl. A350, A380, B787 True Power factor provides 90 kW continous output power at 56°C ambient temperature Mains distortion < 5%THD A A B787

8 Unique Voltage at the Aircraft Plug
400 Hz design rule: 115V ± 3V at the plug at unbalanced load & unsymetrical cables The Patented Plug & Play System is: Quick to prepare Fast to perform Reliable voltage quality at the plug

9 Modular Design: AXA 2400 and Power Coil
AXA KVA GPU Power Coil: 90KVA GPU with Cable Coil Gear Box Motor Change of module with MTTR < 20 min Require No Special Skills Savings on Spare Parts and Maintenance

10 HD Display & Icon Based Menu
AXA KVA GPU Power Coil: 90KVA GPU with Cable Coil HD Display: 3,5 inch (320 x 240 dots) , High contrast and Color Intuitive Icon Menu Software update via USB (from Remote control panel or GPU) Easy daily operation Easy operator training Easy Maintenance

11 References: More 1000 GPUs in ME
KSA – Jeddah New Terminal 100 x AXA 2400 and 88 x ACR Qatar – NDIA 94 x Power Coil UAE – Abu Dhabi Etihad Term. UAE – Dubai Terminal and Aprons 239 x AXA 22/2300

12 References - Special UK – London - B787 at British Airways MRO Oman –
Oman Air MRO Netherlands – Schiphol Airport

13 AXA Power PCA 210 Agenda: Pre-conditioned Air Challenge AXA PCA210
Savings Stepless Regulation Air Quality Easy Operation & Maintenance

14 AXA Power PCA 210 Air Inlet Refrigerant Circuit including:
Compressor + VFD Evaporator Condenser Condenser fan Filtration Electrical cabinet 2 Air Outlets (14’’ each) with one equipped with electrically driven damper Main Blower

15 Special Condensers –Lighter PCA
Micro Channel Condenser More compact and better heat exchange than classic CuAl coils Less amount of refrigerant Less pressure drop Easy to clean Longer lifetime Energy saving Easier maintenance

16 Modular Design – Better Up-Time
Change of module in less than 20 min Require No Special Skills No welding to be done at gate Improved MTTR Few Plugs to be Disconnected EASY TO CLEAN => SOME OF OTHER BRANDS CAN’T BE CLEANED DURING THIER LIFETIME BETTER AIR QUALITY 16

17 Modular Design – Main Blower
Easy Access The module can be removed even when the PCA is mounted underneath the PBB Potential other brands can provide: G2+G4 EN779 class F5 filter (requirement in EN12312-part17) (EN779 ~ ASHRAE 52-1) Airspeed on air intake = 4m/s Best air quality blown into aircraft cabin Longer PCA unit lifetime

18 Stepless Regulation AXA Power Traditional PCA Design
P KW P KW With VFD on Compressors No VFD on Compressors * VFD: Variable Frequency Drive Energy savings with « Stepless control » can exceed 20% Faster response during load variation Energy saving Better pull down comfort optimized for people in and out of Aircraft FOR DEFROST CYCLING WILL NOT STOP THE COMPRESSOR BUT REDUCE AT A MINIMUM ITS FREQUENCY => WE WILL AVOID THE ANTI SHORT CYCLE HAS TO IMPROVE THE ENERGY TO BE PROVIDED TO AIRCRAFT CABIN.

19 Longer Life Time – Internal Plenum
4 condensate pumps Full access at the large openings when the cooling modules are removed Full access to plenum and condensate stainless steel drain pan Type 304 – Classic 18/8 in accordance with ISO 3506 Easy Maintenance clean air to the aircraft cabin. Note: Simulation for hot & wet climate shows that the PCA generates up to 175 l/h (46 gph) water that needs to be pumped away under pressure. Easy Cleaning in less than 2 hours Performance level to be maintained

20 Refrences: More than 200 PCA in ME
Qatar – NDIA – 92 PCA KSA – Riyadh and Madinah – Tot. 55 PCA

21 It’s all about conenctions
Hobart, AXA Power, Houchin & Trilectron are all part of ITW GSE.  Together, we are stronger. See you at stand No


Download ppt "Ready to line up with the best?"

Similar presentations


Ads by Google