PS/SPD VFE Electronics Boxes Repairs Philippe Jacquet, Pascal Perret, Guy Reinmuth LPC Clermont 23 October 2007
2
2 Pascal Perret - LPC Clermont A lot of screws have been damaged when opening/closing of boxes … 1T2T3T4T1B2B3B4B Threading damaged Broken screw Threading damaged Broken screw 5T6T7T8T5B6B7B8B Threading damaged Threading damaged Broken screw PS C-side PS A-side
3
3 Pascal Perret - LPC Clermont A lot of screws have been damaged when opening/closing of boxes … 1T2T3T4T1B2B3B4B Threading damaged Broken screw 5T6T7T8T5B6B7B8B SPD C-side SPD A-side head Screw damaged 16 mm screw! Pipe marked! Threading damaged Threading damaged
4
4 Pascal Perret - LPC Clermont Repairs Repairs done before magnet test! Access very difficult for SPD Scaffolding not very stable Too far from VFE boxes M1 beam is in the way for milling tools … 2 screws not repaired … SPD SM5 top SPD SM7 top Some “helicoils” installed More fragile … Be careful!
5
5 Pascal Perret - LPC Clermont Remarks & Advices M3 screws, 10 or 12 mm long to be used A lot of screws have been damaged when using a worn tool… or screw to hard … Damaged threading comes from screwing not right
6
6 Pascal Perret - LPC Clermont Remarks & Advices Use allen keys in good conditions: if not don’t hesitate to change it or repair it! Apply small strength to screw: use small part of the key … Change screws each time you open a box 2 people are needed to close the cover (top) in order to maintain, push and screw properly (good access is needed!)! Marks have been put on covers (except SPD A top): If you feel it is too difficult, don’t do it: ask for explanation or an expert … More info in attached files 2T 3T Screw in the order 1 – 6 Push the cover according to the arrow directions