Experimental Facilities Division ORNL DAQ System Interfaces Neutron Science Software Workshop Oct 13, 2003 Rick Riedel
2
Experimental Facilities Division ORNL Preprocessor Detector Electronics Detectors PT 0 Dis. Module Chopper Dis. Module Slow Controls Timing Module DAS System Diagram Data/File Server Control Computer F.C. SwitchGbit Switch Firewall 2G optical 1G copper
3
Experimental Facilities Division ORNL “Black Box” View Data Source provider. –Data sets could be as large as 35Gbytes –SNS to generate 130 Gbytes/day…26Tbyte/year. –Histogrammed or event mode Command consumer. –Python scripts embedded in XML requests.
4
Experimental Facilities Division ORNL Feedback Requirement Analysis PC, Cluster, Distributed Domain Data/File Server Firewall Python Script Data (live,background,normalization)
5
Experimental Facilities Division ORNL External Interfaces Firewall –“Live” data via internet (low bandwidth). –Python scripting file gateway –Firewall Data/File Server –File based objects –“Live” data (high bandwidth) –Read Access Only –Short term (as defined in DAS requirements)
6
Experimental Facilities Division ORNL Remote Access--Firewall Availability is controlled by instrument scientist. Html (web page) controlled via password and at control computer. Remote Desktop or VNC portal. Port controlled via password.
7
Experimental Facilities Division ORNL Data/File Server A file server (RAID 0/1) handles data access Pre-nexus format—current run Nexus format—completed runs. Data mining database input( to current Oracle database server) Handles backups
8
Experimental Facilities Division ORNL Data Modes Standard=Histogram, PulseMode = Events identified with time stamp and pulse number. Allows cross correlation with ancillary data.
9
Experimental Facilities Division ORNL Histogramming—Loss of Pulse Information Neutron Events TOF X,Y Counts Time, E, Q, d Pixel Spectrum T.O.F., Space bins Frame n+1 Frame n
10
Experimental Facilities Division ORNL Pulse Mode—Retains Pulse Information. Allows use of correlation techniques. Neutron Events TOF X,Y Frame n+1 Frame n +Pulse Stamp Chopper Phase, Magnetic Field, etc. Chopper Phase, Magnetic Field, etc. Ancillary Data +Pulse Stamp