Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S. Government are within the public domain and therefore are not copyrighted.
2
Background Isocyanate compounds are major components of spray paints used in the aerospace industry Paints contain primarily polyisocyanates with low levels of isocyanate monomer Primarily aliphatic isocyanates
3
Commonly Used Aliphatic Isocyanate Monomers
4
Polyisocyanate Species Found in Paints
5
Polyisocyanate Species Found in Paints (cont.)
7
Complications in Total Isocyanate Determination Vapor and Aerosol Very reactive (unstable) Potentially numerous species for which no analytical standards are available
8
Six Steps in Sampling and Analytical Methods Collection Derivatization Sample Preparation Separation Identification Quantification
9
Collection Efficiency Problems Aspiration efficiency Internal losses Transmission losses
10
Collection Particles – Inhalable Sampler (e.g., IOM): all particles – 37-mm filter: < 20 m – Impinger: 2 m < x < 20 m Vapor – may depend on derivatization
11
Overspray Aerosol Particle Size Rudzinski (1995):4.1 +/- 1.7 m 6.9 +/- 2.5 m Myer (1993):10 - 15 m D’Arcy (1990):2.9 - 9.7 m
12
Derivatization Capture (vapors on filters) Stabilization Detectability
13
Factors Affecting Derivatization Efficiency Inherent reagent reactivity Reagent concentration Reagent-isocyanate mixing
14
Impinger / Filter Comparisons Most field comparisons have found impingers to give higher results - Maitre (1996), Myer (1993), Czarnecki (1992) Rosenberg (1984) found filters to be higher Bello (2000) found IOM = impingers
15
Sampling Recommendations Be flexible Filter – Used for: - All particles < 2 m - Slow-cure particles > 2 m – Extract filters in the field – High-boiling solvent on filters (?) Impingers – Used for fast-cure particles > 2 m
16
Sample Preparation Extraction Sonication Filtration Solvent exchange Concentration Solid-phase extraction
17
Analytical Separation: Reversed-Phase HPLC
18
Analytical Strategies Bulk product for calibration (Bayer) Monomer for calibration (MAP Method, MDHS 25/2, NIOSH 5522)
19
Bulk Product for Calibration Less demanding HPLC and detection Requires that isocyanate composition of calibrant matches composition of exposure
20
Monomer Calibration Demanding HPLC and detection requirements Does not require bulk product calibrant with composition matching exposure Bulk product used qualitatively
21
HPLC: Isocratic or Gradient Elution?
22
Advantages of Isocratic Elution Simple Compatible with EC detector Stable baseline Unvarying response factor
23
Advantages of Gradient Elution Powerful - wider range of compounds Faster Better peak shape
24
HDI/IPDI Oligomer Bulk
25
Identification of Derivatized Isocyanates Monomers - Retention time Oligomers – Retention time – Two detectors - response ratio is diagnostic – Multi-dimensional detector (mass spectrometer, photodiode array)
26
Quantification Monomer and oligomer from monomer calibration curve
27
Conclusions Determination of isocyanates is complex Filter sampling of paints may be OK with short sampling times and field extraction Bulk product calibration or monomer calibration - choice depends on product variability, availability of product calibrants