Download presentation
Presentation is loading. Please wait.
Published byJunior Chandler Modified over 9 years ago
1
TRL-TOC CONFIGURATIONS JUNE 2014, ANKARA Bülent ATAMER
2
Single Shot TOC –Not upgradable with autosampler –Direct TOC not possible
3
p/n: 99-0348-2 Laboratory TC/TOC Analyzer; TRL-TOC-SS Single shot analyzer; not upgradeable with an autosampler; includes: main unit, USB cable to connect to PC, start-up kit including 25 g catalyst and 5 ea quartz sample boats ;required but not included items: PC, gas(either analytical grade air cylinder and pressure regular or air compressor); for 220 VAC, 50 Hz operation; additional one set of consumables kit is recommended for approximately one year operation p/n: 99-0349-2 Laboratory TC/TOC+IC Analyzer; TRL-TOC-SS+IC Single shot analyzer; not upgradeable with an autosampler; includes: main unit, USB cable to connect to PC, start-up kit including 25 g catalyst, 5 ea quartz sample boats and 5 ea 40 mL vial ;required but not included items: PC, gas(either analytical grade air cylinder and pressure regular or air compressor) required; for 220 VAC, 50 Hz operation; additional one set of consumables kit is recommended for approximately one year operation
4
p/n: 99-0350-2 Laboratory TC+TN Analyzer; TRL-TOC-SS+TN Single shot analyzer; not upgradeable with an autosampler; includes: main unit and TN unit, USB cable to connect to PC, start-up kit including 25g catalyst and 5ea combustion boats; required but not included items: PC, gas(either analytical grade air cylinder and pressure regular or air compressor) required; for 220VAC, 50 Hz operation; additional one set of consumables kit is recommended for approximately one year operation p/n: 99-0351-2 Laboratory TC/TOC+TN+IC Analyzer; TRL-TOC- SS+IC+TN Single shot analyzer; not upgradeable with an autosampler; includes: main unit and TN unit, USB cable to connect to PC, start-up kit including 25 g catalyst, 5 ea quartz sample boats and 5 ea 40 mL vial, communication cable between PC and and TRL-TOC ;required but not included items: PC, gas(either analytical grade air cylinder and pressure regular or air compressor) required; for 220 VAC, 50 Hz operation; additional one set of consumables kit is recommended for approximately one year operation
5
TOC with or possibly with AUTOSAMPLER
6
p/n: 99-0989-2 Laboratory TC/TOC Analyzer; TRL-TOC-AS-SS Single shot analyzer; upgradeable with an autosampler; includes: main unit, USB cable to connect to PC, start-up kit including 25 g catalyst and 5 ea quartz sample boats ;required but not included items: PC, gas(either analytical grade air cylinder and pressure regular or air compressor); for 220VAC, 50 Hz operation; additional one set of consumables kit and more quartz sample boats are recommended for approximately one year operation p/n: 99-0990-2 Laboratory TC/TOC Analyzer; For solids sample boats only; TRL-TOC-AS-S Includes autosampler; not included: IC function and liquid pump; upgradeable to universal configuration; includes: main unit and autosampler, USB cable to connect to PC, start-up kit including 25 g catalyst, 5 ea quartz sample boats; required but not included items: PC, gas(either analytical grade air cylinder and pressure regular or air compressor) required; for 220VAC, 50 Hz operation; additional one set of consumables kit and more quartz sample boats are recommended for approximately one year operation
7
p/n: 99-0991-2 Laboratory TC+TOC+IC Analyzer; Universal; TRL-TOC-AS Includes autosampler; universal configuration that handles both solid and liquid samples; TC-TOC-IC all included; includes: main unit and autosampler, USB cable to connect to PC, start-up kit including 25 g catalyst, 5 ea quartz sample boats and 5 ea 40mL vial ; required but not included items: PC, gas(either analytical grade air cylinder and pressure regular or air compressor) required; for 220VAC, 50 Hz operation; additional one set of consumables kit, more quartz sample boats and vials are recommended for approximately one year operation
8
p/n: 99-0992-2 Autosampler Upgrade Factory trained service person required for field upgrade; to convert TRL-TOC- AS-SS to TRL-TOC-AS-S p/n: 99-0353-2 TN Module Easy to start up; includes: TRL-TN module with ozone generator and chemiluminescence detector, USB connection cable and power cable p/n: 99-993-2 Universal Upgrade Factory trained service person required for field upgrade; to convert TRL-TOC- AS-S to TRL-TOC-AS
9
p/n: 95-0653-1PC min configuration: window 7, intel Core 3i, 1GB RAM, 100GB HDD, CD-ROM, 2xUSB port p/n: 95-0654-1Balance 0,01 mgr readability; 25 gr capacity; data transfer capability p/n: 95-0656-1TOC Gas Generator Generates CO2 and hydrocarbon free air at steady 2 bars pressure and continuous 3L/min flowrate, includes a noiseless and oil-free compressor p/n: 95-0657-1Communication Cable; PC to TRL-TOC USB to USP cable, 1m p/n: 95-0658-1Flow Calibrator BIOS Model Defender 510, NIST traceable tested under ISO17025 GLP; flow range: 50-5000mL/min; accuracy: 1% of full range
10
96-0449-1Consumables kit for TC/TOC and TC/TOC+TN configurations Includes: 1 btl (25gr) catalyst; 25 ea quartz sample boats; 1 ea dryer, permeation; 1 set of HT furnace inlet o-rings (set of 3); 1 set of HT furnace closure o-rings (set of 2) 96-0450-1Consumables kit for IC configurations Includes: 25 ea 40 mL sample vial, 5 ea septa, 5 ea screw cap; 1 ea dryer, permeation; 1 ea IC needle 97-0659-1Catalyst, 25 gr in colored bottle 97-0141-1Dryer, permeation 01-0299-1Pyrex liquid separator 97-0272-1Sampling nozzle, 1/25, standard 97-0347-1Quartz sample boat, for single shot loader car only, 12mL 97-0171-1IC sample vial, 40 mL, without septa and screw cap 97-0172-1A set of septa and screw cap for 40 mL IC sample vial
11
96-0994-1Consumables kit for TRL-TOC-AS-SS configuration Includes: 1 btl (25gr) catalyst; 5 ea quartz sample boats; 1 ea dryer, permeation; 1 set of HT furnace inlet o-rings (set of 3); 1 set of HT furnace closure o-rings (set of 2) 96-0995-1Consumables kit for TRL-TOC-AS-S configurations Includes: 25 ea sample vial with septa and screw cap; 1 ea dryer, permeation; 1 ea IC needle 97-0659-1Catalyst, 25 gr in colored bottle 97-0141-1Dryer, permeation 01-0299-1Pyrex liquid separator 97-0272-1Sampling nozzle, 1/25, standard 97-1015-1Quartz sample boat, for autosampler, 12mL 97-0171-1Sample vial, 40 mL, without septa and screw cap 97-0172-1A set of septa and screw cap for 40 mL IC sample vial
12
Net Transfer Price($)Distributor's DiscountEnd User Price($) 100030% 1.429 50020% 625 10010%111