ATLAS 1 Beam Pipe Support Structure (BPSS) Interface and Assembly Final Design Review, April 2003 E. Anderssen, N. Hartman LBNL.

Similar presentations


Presentation on theme: "ATLAS 1 Beam Pipe Support Structure (BPSS) Interface and Assembly Final Design Review, April 2003 E. Anderssen, N. Hartman LBNL."— Presentation transcript:

1 ATLAS 1 Beam Pipe Support Structure (BPSS) Interface and Assembly Final Design Review, April 2003 E. Anderssen, N. Hartman LBNL

2 ATLAS 2 Services and Beam Pipe Support Structure Beam Pipe Support SCT Barrel TRT Forward Side CSide A Services and Beam Pipe Support Structure Pixel Detector Schematic of Beampipe, Support Structure, and Pixel Package in ID TRT Forward Beam Pipe Support Wire ID Endplug PP1 PST Support Flexures Insertion Trolley Beam Pipe Pixel Support Tube Package Insertion Riders Z=848 – Wire Support Z=3092 – PP1 Z=3120 – Adjustors PP1 Bellows/Temporary Support Z=~3200 – Bellows/Temp. Support

3 ATLAS 3 “Package” Beam Pipe Support Structure Pixel Detector Not Shown Beam Pipe Service Panels

4 ATLAS Rails

5 ATLAS 5 Service Quarter Panel Service Quarter Panel structure carries Disk and Barrel panels as well as PP1 quarter panel on same structure Disk panels not shown—current designs being modified Tubes not shown as well—both available at June Review

6 ATLAS 6 PP1 Routing Routing for PP1 dominates the volume at the end of the Package The routing is not complete, but is intended for Review in June Bellows design to couple PP1 to Beam Pipe is ‘Complete’ implies ~73N compressive load on Beam Pipe during Bakeout. Uses Large Convolution depth, but relatively short length Dimensions open to discussion, based on acceptable loads (can increase length/convolution depth ratios to suit acceptable load and internal clearances

7 ATLAS 7 Patch Panel One PP1 layout determines final length of the Forward section of the PST—Layout of region is progressing and being modelled—in time for June (only just)

8 ATLAS 8 PP1 Interface to Adjustors Survey access is poorly understood now Hope to reduce some occupancy of PP1 fittings Bellows design exists, can be optimized for possible access Internal volume of BPSS is not a limit as will be seen in later slides Non conventional options for survey will likely be needed Temporary support of Beam Pipe is from ‘Can’ installed on inner radius of PP1 Fixation of service structure to PP1 Quarter Panel Breaks

9 ATLAS 9 PP0 End of Frame PP0 is not technically an interface to Beam Pipe but is a critical interface to BPSS Disk/B-Layer panels under revision currently—not shown Trolley is designed to allow for cooling tubes which are also installed with Service Quarter Panels Note—PP1 quarter panels are fixed to the Service Quarter Panels and are installed with them This is important at a later stage where PP1 will support the Beam Pipe

10 ATLAS 10 Pixel package Overview The Pixel package is first integrated on surface into an Integration & Testing Tool (ITT) and then slid into a Dummy Support Tube (DST) the DST in then lowered into the pit in a cradle, connected and aligned to the PST and the pixel system is moved to its final position The Beampipe is the first article installed in the ITT Dual V Rail System Wheels and driving system U Supports Support Frame B- Layer Cart

11 ATLAS 11 Pixel Assembly Beampipe temporarily held with auxiliary supports “U-Supports” on installation and testing tool - ITT

12 ATLAS 12 Beampipe support transferred to support frames—see comments Following slides Pixel Assembly

13 ATLAS 13 Beampipe Support Frame Wires at Z=-848,+848 Fixed Adjustors (no spring) Top and Side Sprung Adjustors Side and bottom (tension limiters) Wire Adjustors Cruciform supports Longerons Service panel Attachment points Reinforcing Longerons, Attach Points to PP1 2 Frames – 1 A Side, 1 C Side Single Frame Shown Here 4 Support Wires, 1 Support Plane

14 ATLAS 14 Beam Pipe Collars Split Conical Ring Allows Free Placement in Z Wire Anchor Point Kapton Heater Aerogel Insulation

15 ATLAS 15 Access to wires during Assembly Access to wires prior to Service Panel installation is excellent Service Panels installed after the wires are routed through tubes Wires then inserted through adjustors at end of longerons Longerons

16 ATLAS 16 Assembly of Adjustor/Limiter Unit Tension Limiter Assembled, Spring Compressed Wire Fed Through, Clamped into Collet Wire Adjustor Seated in Tension Limiter Max “IN” Adjustment Max “OUT” Adjustment

17 ATLAS 17 Adjustor/Tension Limiter Preload Adjustor Barrel Limiter Spring Wire Adjustor Screw Wire Adjustor Nut Wire Collet & Nut Wire Tension Limiter Plunger Wire Guide

18 ATLAS 18 Assembly Continued—Services Added Service Panels Are Added to top of package Bottom of package has limited access due to ITT support structure Note that half of PP1 is assembled at this stage, and can be fastened together Temporary support via PP1 is possible at this stage

19 ATLAS 19 Bottom Services Installed Bottom services can be installed Note—this picture shows direct bottom, Package can rotate only 90 degrees plus a little in the ITT At this stage it is required to have temporary supports of Beam Pipe installed to allow for this rotation

20 ATLAS 20 Panel Installation Detail This shows some detail of how panels are supported to provide adequate support for the temporary support Note that PP1 is threaded over Adjustors during installation


Download ppt "ATLAS 1 Beam Pipe Support Structure (BPSS) Interface and Assembly Final Design Review, April 2003 E. Anderssen, N. Hartman LBNL."