1 Fabrication and measurement of RF components for CLIC study
CERN summer school programme 2010 Fabrication and measurement of RF components for CLIC study Thapakron Pulampong Physics department, Khon-Kaen University, Thailand 18/8/2010

2 RF flanges + straight waveguides
Objective: To study how Cu-plating (12-15 µm) of RF flanges affects vacuum and RF properties after brazing with straight waveguides. - brazing - vacuum leak test - RF measurement Diffusion bonding study (PSI prototype disks) Objective: To study diffusion bonding quality using metallographic observation. - chemical cleaning for disks - diffusion bonding process - metallographic observation

3 RF flanges + Straight waveguides
Machining->Chemical cleaning Cu layer12-15 µm Machining->Chemical cleaning-> Ni-plating -> Cu-plating

4 Brazing of RF flanges with a waveguide
Under vacuum With brazing wire Ag/Cu/Pd at °C (Bodycote) (Silver/Copper/Palladium) Structure after brazing

5 Vacuum leak test With A.Olyunin
Clean bolts and nuts with alcohol and ultrasound 20 minutes Clean vacuum flanges with alcohol Vacuum leak detector Connect vacuum flanges with the structure

6 Object: RF flanges and straight waveguide
CERN TE/VSC LEAK TEST CERTIFICATE Description of examination Customer: CERN BE/RF Object: RF flanges and straight waveguide Leak test date: Leak detector type: LEYBOLD L200⁺ . Reference leak rate: ±15% ×10⁻⁷mbar×L/s Minimum detectable leak rate: 1×10⁻¹¹ mbar×L/s Tracer gas: Helium 99% System pressure: ×10⁻³ mbar Test temperature: ̊C Examined part Brazing Results Max. measured leak rate: × mbar×L/s Good results!

7 RF measurement With A.Olyunin RF flanges+waveguide RF test flanges
Clean all surface to be connected with alcohol Connect RF test flanges with RF flanges +waveguide Connect network analyzer with the sample and start testing RF test flanges 2ports network analyzer Calibrated before test

8 RF measurement result Good results! Frequency (GHz) S-parameter (dB)
Good results!

9 Diffusion bonding test
Bonding temperature : 1040 °C Time : 1h 30m Atmosphere : H2 Prototype disks for PSI accelerating structures Regular cell disk: 2-46 Wake monitor cell disk:8-43 Wake monitor dell disk:5-40 Wake monitor cell disk:4-37 Wake monitor cell disk:3-36 Regular cell disk: 2-35 INSERT1 INSERT2 Standard cell disk 2-55 Stack no.1 Stack no.2 with 1 insert for test validation process of bonding or brazing.

10 Chemical cleaning procedure
Degreasing with detergent NGL 17.4 spec. ALU III and ultrasound Deoxidation with HCl acid Etching with SLAC solution Final rinsing with demineralised water and ultrasound Dry with nitrogen gas Dry with oven With M.Balabaila

11 Vacuum before H2 injection for diffusion bonding
Bodycote Root pump 10-3 torr Primary pump 10-1 torr Diffusion pump 10-6 torr

12 Diffusion bonding Heating system made of Molybdenum screens (melting point is °C): temperature of °C for the bonding process.

13 Cool down Cooling system is composed of water cooling and air cooling.
Water spray Because of water spray and cooling turbine, the temperature can be reduced rapidly. Cooling turbine Air tank

14 Diffusion bonding no.1 weight of 16 Kg Vacuum  H2  Heat up to 1040 C
CERAMICS 4 temperature probes (thermo-couples) in tuning holes Furnace warm up and clean up ceramics and support before bonding. Bonding process 1:30h

15 Diffusion bonding no.2 weight of 16 Kg CERAMICS 2 temperature probes
(thermo-couples) Furnace warm up and clean up before bonding. Bonding process 1:30h

16 Stacks after Bonding Stack no.1 Stack no.2 with 1 insert

17 Metallographical observation
M. Aicheler Metallographical observation Bonding no.1 SOI 6 SOI 5 SOI 1 SOI 2 SOI 7 SOI 4 Stack no.1 after cutting Contact reference line

18 Metallographical observation
M. Aicheler Metallographical observation Bonding no.2 5 4 3 2 1 SOI 6 SOI 7 SOI 5 SOI 1 SOI 2 SOI 3 Stack no.2 after cutting Installed insert before bonding process after cutting

19 Stack no.2 metallographic observation
Joint no. 4 Joint no. 5 Grain crossing Grain crossing Contact reference line Designed contact zone Designed contact zone M. Aicheler

20 Conclusion RF flanges + straight waveguides Bonding tests
Vacuum leak 3.6× mbar·l/s (< )( Good) RF reflection about -30 dB (Good) Bonding tests Successful: grain crossing can be found in areas with and without designed contact. Inserts should not be diffusion bonded, but brazed, as originally foreseen.