Download presentation
Presentation is loading. Please wait.
Published bySamuel Robbins Modified over 9 years ago
1
2X800 MW, YERMARUS HIGH PRESSURE HT COMPLETED ON 25.09.2015 IN THE PRESENCE OF JOINT DIRECTOR OF BOILERS KARNATAKA
2
POOJA PERFORMED BY JDB & TEAM Shri. T G Manjunatha JDB Karnataka Shri. Sundara Rajan AGM Site Incharge Shri. Parimala Jana AGM Shri. Venugopal SE, RPCL Shri. S Sridhar AGM
3
THE HIGHEST PRESSURE - BFD HT HT PRESSURE 675 kg/cm 2
4
THE BFD HT ( INCLUDING HEATERS ) HT PRESSURE 525 kg/cm 2
5
EXTRACTION 3,4 & 8 HT HT PRESSURE 142.5 kg/cm 2 HT PRESSURE 10.5 kg/cm 2
6
TESTED CIRCUITS UNIT#1 BFD FROM PUMP TO HP HEATERS & RECIRCULATION BFD FROM HP HEATER TO BOILER TP EXTRACTIONS 3,4,5,6 & 8 AUX STEAM HFO HEATING AND ATOMISING LINES UNIT#2 CRH FROM NRV TO BOILER TP INCLUDING HPBP DOWNSTEAM TO CRH, CRH TO DEAERATOR, EXTRACTION FROM CRH TO TDBFP A&B, CRH TO PRDS, EXTRACTION FROM CRH TO HPH -7A & 7B.
13
RECORD BREAK YERMARUS TEAM HAS ACHIEVED A RECORD COMPLETION OF HT FOR MORE THAN 10 CIRCUITS CONSECUTIVELY FOR SECOND TIME HYDRO TEST COMPLETION OF 16 NOS. OF CIRCUITS ON 25-09-2015. HYDRO TEST COMPLETION OF 12 NOS. OF CIRCUITS ON 10-08-2015. BREAK A RECORD
14
TEAM MEMBERS (JDB/BHEL/RPCL/STEAG/ICPL)
15
THANK YOU
Similar presentations