Download presentation
Presentation is loading. Please wait.
Published byNigel Allison Modified over 9 years ago
1
Electrical Power Distribution
2
Forms of Energy All forms of energy fall under two categories POTENTIAL Stored energy or energy of position (gravitational) KINETIC Energy of motion (motion of waves, electrons, atoms, molecules, and substances)
3
Work Power Electrical Power is measured in Watts (W) or kWatts (kW) W = joule per second Work is done when a force that is applied to an object moves that object. The work is calculated by multiplying the force by the amount of movement of an object (W = F * d).
4
Power Generation
5
Power Transmission Lines
6
Power Generation and Transmission
7
Electrical Systems Incoming Service - Power Switchgear / Distribution Equipment Feeders Grounding Motor Br. Branch/Equip. Connect Emergency Generators / ATS / UPS Lighting Fixtures / Lighting Control Devices - Lighting Devices - Power Lighting Branch Power Branch Fire Alarm System Site Lighting Telephone / Data Conduit Incoming Service - Telephone
8
Electrical Terms Utility Power XFMR Switchboard Panelboard Motor Control Center Disconnect Switch Transformer Circuit Breaker Feeder One-Line Diagram Equipment Connection Branch Circuit Homerun Receptacle Switch Automatic Transfer Switch Generator UPS
9
Electrical Symbols
10
10 Service equipment is the electrical equipment that constitutes the main control and means of power cutoff to the electric service (normally Power Company supply) brought into the building. Service Equipment
11
11 All buildings have an electrical service. Primary service (utility company) is shown on the one-line diagram.one-line diagram A utility transformer is installed outside the building on a pad (site drawing) or pole. Incoming Service - Power
12
12 Incoming Service - Power
13
13 Incoming Service - Power
14
14 Common Electrical Distribution Systems
19
1φ2W, 240 Vac 1φ3W, 120/240 Vac 3φ3W, 240 Vac 3φ3W, 240 Vac corner ground delta 3φ4W, 208Y/120 Vac120 x 3 = 208 V 3φ4W, 480Y/277 Vac277 x 3 = 480 V 3φ3W, 480 Vac 3φ4W, 600Y/347 Vac 3φ3W, 600 Vac 2W, 250 Vdc 3W, 125/250 Vdc
20
Residential Power Distribution
21
Commercial and Industrial Power Distribution
22
Utility Primary Transformer
23
23 In-Coming Service - Power
24
Carpenters International Training Fund Program 3 – 8 Feeders 24 Incoming Service – power feeders
25
One-Line Diagram
28
Power Distribution System Equipment
30
30 Switchboard
31
Main Distribution Board (MDB)
32
32 Main Distribution Board (MDB)
33
Main Switchboard (MSB)
34
Incoming Section Meter Main Section Distribution Section Circuit Breakers Fusible Switches Grounding Bonding Switchboard
35
Incoming Section Meter Main Section Distribution Section Circuit Breakers Fusible Switches Grounding Bonding Switchboard
36
Incoming Section Meter Main Section Distribution Section Circuit Breakers Fusible Switches Grounding Bonding In-Coming Service - Power
37
Incoming Section Meter Main Section Distribution Section Circuit Breakers Fusible Switches Grounding Bonding Switchboard
38
Incoming Section Meter Main Section Distribution Section Circuit Breakers Fusible Switches Grounding Bonding Switchboard
39
Incoming Section Meter Main Section Distribution Section Circuit Breakers Fusible Switches Grounding Bonding Switchboard
40
Incoming Section Meter Main Section Distribution Section Circuit Breakers Fusible Switches Grounding Bonding Switchboard
41
Incoming Section Meter Main Section Distribution Section Circuit Breakers Fusible Switches Grounding Bonding Switchboard
42
42 Panelboard
43
43 Panelboard MCBMLO
44
44 Panelboard Primary Transformer [480/277V 3 ϕ 4W] Power Panelboard Panelboards Lighting, appliances, motor/equip Step-Down Transformer [120/208V 3 ϕ 4W] Main Breaker Enclosed Disconnect
45
45 Panelboard
46
Motor Control Center (MCC)
47
Safety Switch - Disconnect Switch Fusible or Non Fusible 250V or 600V 2 Pole or 3 Pole 30A 60A 100A 200A 400A 600A 800A 1200A
48
Disconnect Switch 4 & 6-Pole Heavy Duty Safety Switches Two-speed, two-winding motors 4-pole switches are also used in 3-phase, 4-wire circuits when a switching neutral is required.
49
49
50
Disconnect Switch
51
Five Guys Burgers and Fries
57
Accubid Office Building
58
12
59
1 5 4 1 4
60
1 5 1 4 3 9 3 4+1=5
61
12 1 5 1 4 3 9 3 4+1=5 5
62
12 5 4 1 1 5 1 4 3 9 3 4+1=5
63
12 5 4 1 4 1 4 1 4 1+3 4 1 3 1 4 1 1 3 1 4 1+1 1 1 4 12 3 9 3 4+1=5 5 3 1 1
64
Accubid Office Building PNL HB1 Branch CircuitsHNG (8) 20A 1P ACCUBID OFFICE BUILDING WIRE POWER TERMS – BRANCH CIRCUITS AND MOTORS (Panel Schedule and Motor Schedule) 6#122#101#12 2#121#101#12 (10) #12 (3) #10 HHHNHHHNGHHHNHHHNG Maximum Number of Conductors in a ½ " EMT Conduit = (9) #12 NEC Annex C, Table C.1
65
Accubid Office Building PNL H1 Branch CircuitsHNG (8) 20A 1P Motor and Equip FPB3#10, #12 Gx8 UH-13#12, #12 Gx1 ACCUBID OFFICE BUILDING WIRE POWER TERMS – BRANCH CIRCUITS AND MOTORS (Panel Schedule and Motor Schedule) 6#122#101#12 2#121#101#12 (10) #12 (3) #10
66
Accubid Office Building PNL H1 Branch CircuitsHNG (8) 20A 1P Motor and Equip FPB3#10, #12 Gx8(8) #12 (24) #10 UH-13#12, #12 Gx1(4) #12 ACCUBID OFFICE BUILDING WIRE POWER TERMS – BRANCH CIRCUITS AND MOTORS (Panel Schedule and Motor Schedule) 6#122#101#12 2#121#101#12 (10) #12 (3) #10 (22) #12 (27) #10
67
Accubid Office Building PNL L1 Branch Circuits (45) 20A 1P Motor and Equip 70A 2P22/24 50A 2P26/28 WH-12#12, #12G ACCUBID OFFICE BUILDING WIRE POWER TERMS – BRANCH CIRCUITS AND MOTORS (Panel Schedule and Motor Schedule) E3.1
68
Accubid Office Building PNL L1 Branch CircuitsHNG (45) 20A 1Px7 Motor and Equip 70A 2P22/242#4, 1#8 50A 2P26/282#8, 1#10 WH-12#12, #12G ACCUBID OFFICE BUILDING WIRE POWER TERMS – BRANCH CIRCUITS AND MOTORS (Panel Schedule and Motor Schedule) 6#122#101#12 3#121#101#12 (53) #12 (15) #10 (56) #12 (16) #10 (3) #8 (2) #4 E3.1
69
Accubid Office Building PNL HT (H2, H3, & H4) Branch CircuitsHNG (5) 20A 1P Motor and Equip FPB3#10, #12 Gx7(7) #12 (21) #10 EF-13#12, #12 Gx1(4) #12 ACCUBID OFFICE BUILDING WIRE POWER TERMS – BRANCH CIRCUITS AND MOTORS (Panel Schedule and Motor Schedule) 5#122#101#12 (6) #12 (2) #10 (17) #12 (23) #10
70
Accubid Office Building PNL LT Branch Circuits (11) 15A 1P Motor and Equip WH-12#12, #12G ACCUBID OFFICE BUILDING WIRE POWER TERMS – BRANCH CIRCUITS AND MOTORS (Panel Schedule and Motor Schedule)
71
Accubid Office Building PNL LT Branch CircuitsHNG (11) 15A 1P Motor and Equip WH-120A 2P2#12, #12G ACCUBID OFFICE BUILDING WIRE POWER TERMS – BRANCH CIRCUITS AND MOTORS (Panel Schedule and Motor Schedule) 6#122#101#12 5#122#101#12 (13) #12 (4) #10 (16) #12 (4) #10
73
Accubid Office Building Takeoff: Distribution
75
Accubid Office Building Takeoff: Distribution
76
Accubid Office Building Takeoff: Distribution
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.