F All Experimenters' Mtg - 27 Jan 03 Week in Review: 01/20/03 -01/26/03 Ron Moore – FNAL Found obstacle in AP-1 line Replacing corroded Tevatron dipole.

Similar presentations


Presentation on theme: "F All Experimenters' Mtg - 27 Jan 03 Week in Review: 01/20/03 -01/26/03 Ron Moore – FNAL Found obstacle in AP-1 line Replacing corroded Tevatron dipole."— Presentation transcript:

1 f All Experimenters' Mtg - 27 Jan 03 Week in Review: 01/20/03 -01/26/03 Ron Moore – FNAL Found obstacle in AP-1 line Replacing corroded Tevatron dipole stands

2 f All Experimenters' Mtg - 27 Jan 03R. Moore - FNAL2 AP-1 Line Obstruction After 11/17 beam accident that caused vacuum leak at TOR105, saw higher than usual losses nearby and higher emittance growth of pbars in region during shots –Pbar emittances increased 7-8  (up from 3  ) between Acc and MI Opened AP-1 at SEM grid 103 on 12/3 – nothing seen, but SEM wire dangling at edge of aperture –Wire removed, but problem was unresolved

3 0 2 4 6 8 10 12 14 050100150200 Store number since April 2002 AP-1 vacuum problems 11/16/02 Pbar emittance growth between the Accumulator and M.I. Courtesy Jim Morgan

4

5 f All Experimenters' Mtg - 27 Jan 03R. Moore - FNAL5 AP-1 line schematic obstacle here protons for stacking pbars from Acc to MI

6

7 Plastic beampipe cap removed from AP-1 line on 1/21 Protons came out of page; pbars went into page

8 f All Experimenters' Mtg - 27 Jan 03R. Moore - FNAL8 Plastic Cap in AP-1 Thought to have been there many years… –Hard to notice once hole was formed Red cap moved during vacuum incident in Nov. –Beam no longer through hole  problem appears After removal, expect reduced pbar emittance growth between Accumulator and Main Injector –Perhaps slightly smaller pbar emittances in Tev, too –No earth-shattering improvements expected

9 f All Experimenters' Mtg - 27 Jan 03R. Moore - FNAL9 Tevatron Magnet Stand Replacements Replacing stands for dipoles A16-3, A21-2, A21-3, A21-4 –Stands appear very corroded – safety issue “Quick and dirty” mechanical measurements indicate significant dipole rolls; to be confirmed with optical survey –These rolls make the dipole correctors run harder, but not a big problem currently –At least one quad (not low-  ) rolled significantly? Will just replace stands now; fix alignment later Catalog all magnet stands, roll measurements now –address stand replacement, alignment later

10 Tev A16-3 Dipole Photos courtesy Ray Stefanski

11 courtesy Todd Johnson Tev A16-3 Upstream Stand

12 f All Experimenters' Mtg - 27 Jan 03R. Moore - FNAL12 Summary Found and removed red plastic pipe cap in AP-1 –Been there for a long time –Source of proton losses during stacking, pbar emittance growth during shots Replacing stands of 4 Tevatron dipoles –Stands very corroded, posed a safety hazard –Catalog all other magnet stands for future work