BWS PS and SPS problem report J. Emery 21.07.2015
2
11.07.2015 JIRA https://issues/browse/BIWS-539 PS 54H found in wire-reset home with Motor power supply problemhttps://issues/browse/BIWS-539 Problem: 11/07/2015 05:08 LDB shows only part of IN scan (pts overflow), no Out scan Status: FGen busy FGen not at max Wire-rst home Scan on-going Scan check: 11/07/2015 19:02 and 19:04 LDB shows no profiles, but status are coming back to normal. Check all this month scans showed no errors Suspicion on the PowerAmplifier Amplifier changed 13.07.2015 at 14h30 Multiple scans on all the scanners shown good movements All data reduction disabled to be able to see all the movement in case of problems. Extensive testing in the lab shown that the PowerAmplifier is functional……
3
20.07.2015 JIRA https://issues/browse/BIWS-541 PS 85.V stayed in wrong position in the beamhttps://issues/browse/BIWS-541 Problem: 19/07/2015 18:00 ? Scanner stayed in the middle of the stroke around 32000 [bit of potentiometer] All beam stopped at 18:22 Ana went in the PS to move back the mechanism out of the beam Last LDB data at 18:00:22 shows only IN scan, no OUT scan Server last scan is on MD4 user shows raw movement OUT is OK| => SW treatment issue?
4
20.07.2015 JIRA https://issues/browse/BIWS-541 PS 85.V stayed in wrong position in the beamhttps://issues/browse/BIWS-541 From Ana’s mail: 1) The first scan we did on this user left the scanner IN. => No record in LDB or in Server, Why? 2) Large losses, beams stopped, pot at 24000 (IN position). 3) INIT HW, since FGEN at max (correctly at IN position) 4) ERROR, wire still in? in the middle, position at 32000 bits. 5) No clue why last scan and InitHW has no LDB? 6) Bit 10 raised of the mcStatus (large difference in voltage potentiometer-requested position). => Could indicate an issue with PowerAmplifier 7) Data reduction was enabled in purpose => Missing movement information 8) No power supply error detected. Hardware next steps options: Remove power supply and check in the lab => Next week technician is back to test it. If PowerSupply if broken => Install new one in the machine. If PowerSupply is fine => Install new (or old one) and check in the machine during TS. Software next steps: 1)Check why we have RAW positions, by not out position 2)Check why the server is then missing Logging entries after that (when we have a problem
5
21.07.2015 https://issues/browse/BIWS-542 SPS 416.H WARNING: “Problem resetting position” Called by SPS OP 416 can’t be moved Warning message shows: "Problem resetting position“ Potread: 38843 (Home position) Last scan: 19/07/2015 22:29:25 Nothing special seen from the LDB extraction. Positions are OK Status are OK
6
21.07.2015 SPS 519.H Message: “Delay problem” from OP GUI Called by SPS OP 519 can be moved Warning message at the OP GUI: “Delay Problem“ The server don’t show this error This must be coming from OP GUI Nothing special seen from the LDB extraction. Positions are OK Status are OK