Analysis of the dynamics of the decay + - o Referees report Mario Antonelli, Luca Passalacqua KLOE general meeting 10-10-2002
2
General: competitive results + 2000 data KLOE note soon draft Analysis is in a good shape: relevant detector effects taken into account several checks DATA-MC systematic uncertainties evaluation robustness of the fit Main questions: bias on momentum measurement ISR not taken into account Detailed description in the KLOE MEMO 274 Comments
3
Momentum bias difference in measured momenta between negative and positive charged particles observed in the control samples: and events P(+)-P(-) (MeV) NOW: main systematic for Ms mesaurements 0.5 MeV ONLY the AVERAGE enter in ( Ms) Profiles + lab frame
4
Momentum bias Referees comment: find source(s) of the effect correct measured momenta (use control sample) verify consistency with o mass systemaitcs from uncertainties on correction Closer look to the effect: rest of frame + use gaussian fits to slides P(+)-P(-) (MeV) ~ 280 KeV average slides + frame 50 o < <130 o
5
Momentum bias the wire droop is not taken into account in the present track reconstruction algorithm bias on the momentum ? X-Y view w ~ 200 mNot in scale Sagitta (s) p t =p t 2 /(0.3BL t 2 )8 s error on the wire poistion ss ptpt ssdroop ~ R-Z view 100 m 300 keV @ p=500MeV
6
Momentum bias Charge dependent effect: X-Y view + / – s for + / - charge X-Y view dependent effect ww ss effective bias Parallel component to the sagitta s= w cos
7
Momentum bias R-Z view dependent effect Only relative positions are important If wires have same droops w no effect at =90 o s w X-Z view =0 s w s At small angle
8
Momentum bias w is not a constant effect at =90 o expected (and observed)
9
Momentum bias use a toy model to verify consistency with data linear droop vs z evaluate average of effective s: dependencies and differences in w(0) vs R taken into account curvature effect on effective s also considered z w(0) Not negligible R~1 m dependence ( s) on the wire
10
Results P(+)-P(-) (MeV) 50 o < <130 o check the model at low angles (large effects are expected)
11
results Use bhabha P(+)-P(-) (MeV) 35 o > >155 o A bit asymmetric… under study Tilted plates?
12
ISR effects? Initial state radiation not taken into account in the fit o E,P evaluated from missing E,P using knowledge of W Some event with o kinetic energy out of boundaries? Fit stability checked varying cuts on variables sensitive to ISR