Download presentation
Presentation is loading. Please wait.
Published byAubrie Blair Modified over 9 years ago
1
HES HKS collaboration meeting 3/11/2010 T.Gogami
2
T-zero adjustment WC AC High current run beta distribution
3
ideally, detectors are plane Detectors have segments timing differences of each segment cable length, module propagation time …. Need to be correct Time–zero adjustment The ways to correct 1. with t-zero counters (HTOF2Y, EHODO3) 2. without t-zero counter
4
set parameters to be T 1 =T 2 =T 3 =…. T1T1 T2T2 T3T3 t – zero counter TOF [ns] in the case of EHOOD2 during experiment HES side
5
assumption d = d’ T0T0 T1T1 T2T2 d d’ set parameters to be 1. T 0 = T 1 2. (T 0 = ) T 1 = T 2 3. (T 0 = T 1 = ) T 2 = T 3 =… T1T1 1 2 during experiment HES side (edge) HKS side after experiment (fine tune) HES side HKS side
6
correlation is straighter in FP x vs. β - β K Kaon peak is on “0” in β - β K
7
TOF resolution σ ; 460 [ps] 360 [ps] long tale
8
Odd number counter’s TOF have long tale EH1 ID – EH2 ID
9
EHODO2 – 17, 19, 21, 23, (25, 27, 29) are bad Discriminator ?, ECL cable ?, TDC slot? EH1 ID – EH2 ID
10
event loss EH2 bad channel should be excepted K + coincidence time K+K+ 17 19 21 23 25
11
EHODO1 EHODO2
12
separate clearly
13
easier to select K + than before need two cut
14
hwatnkn1+2 > 1.2 X = 1.2 X = 0 K+K+ K+K+ p p 1 dimensional cut X cut β - β K
15
new box 4/15/2009 – 7/1/2009 (78 days) Trigger EH1 × EH2 78 days EHODO WC EHODO μ stable
16
1-4 1-61-11 1-12 2-2 2-52-7 2-10 39 days 63 days NPE high momentum side low momentum side 39 days 63 days NPE 39 days 63 days NPE 24 days
17
teflon if so, only high momentum side PMT thermal dependence water (chemicals … ) …. etc reduced ~10 % cause
18
X AC NPE1+2+3 < X π K+K+ X at X = 10 K + 93 % π + 10 % X = 30 10 Be, 40 [μA] β - β K π+π+ K+K+
19
High current run K + beta distribution is not clear at low momentum side PMT sagging ?, TOF parameters ?, high multiplicity ? CH2 2uA Cr 8uA WC 1-1 & 1-2 K + NPE distribution
20
T-zero adjustment 1 st fine tuned EHODO2-17, 19, 21, 23, 25, 27, 29 are bad should except WC normalized NPE survival ratio of different threshold K + NPE reduction AC survival ratio of different threshold High current run beta distribution low momentum side beta is not clear at high current run
21
selected bad counter
25
1-dimensional cut
27
NPE fit resultCosmic & HYCS From kaon NPE reduction parameter estimate Kaon NPE just after beam time ratio of expected value from cosmic ray study + HYCS ~88%
28
in the Hall
29
in counting room
30
during experiment σ~420[ps] TOF Counter ID TOF
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.