Download presentation
Presentation is loading. Please wait.
Published byHugh Wright Modified over 9 years ago
1
Classical and Finite Difference Method to Estimate pile Capacity Compared With Pile Load Test Results Yogesh Prashar, P.E., GE Force Pulse Conference, DFI January 2012 Oakley, California www.m2consultantsinc.com
2
Presentation Outline Description & Background Pile Load Testing & Results ETC –3 Conventional Uplift Tests –12 RLT Compression Theoretical Load Settlement Calculations FLAC Simulation of Uplift & RLT Comparisons & Rapid Loading BART, UCSF, & N4 West Conclusions
3
Site MapSite Air Photo Emeryville, N. California
4
900’ 400’ 15-test Pile Locations 12 RLT 3 Uplift - Pile Load Test 16-in Square pre-cast concrete piles RLT Conventional Uplift Test
5
Site Plan & Boring Locations Cross Section Line A-A’ & B-B’ 12 Borings & 7 CPT’s Laboratory Testing A’ N TEST AREA Site Plan & X-Section Line
6
900-ft Soil Profile
7
CU Triaxial Testing
8
Emeryville Soil Profile *=Friction angle and Cohesion parameters were increased 25 & 50% in parametric analysis Fill: (pre-drilled) Soft - Silty Clay Firm Sandy Clay Stiff Sandy Clay V. Stiff Sandy Clay 10’ 35’ 10’ 18’ 115 20 0 NA 110 5 200 0.9 125 20/24.5/28.6* 400/500/600* 0.9 130 24/27.9/32.5* 600/750/900* 0.8 130 27/32.5/37.4* 1000/1250/1500* 0.75 No. 16” Square Pile Soil Type (pcf) (deg) C (psf) Ca/C 1234512345 86’
9
0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 25.0 35.0 45.0 55.0 65.0 75.0 85.0 95.0 PILE LENGTH (ft) PILE DRIVING (BLOWS PER FOOT ) IP7 IP8 IP9 IP10 IP5 IP11 IP12 IP13 Pile Driving Blow Counts & N-Values
10
ASTM D 1143 Static Pile Load Test Three piles were tested Load applied with hydraulic jacks Deflection by Dial indicators Plotted Measured Load versus deflection Material Parameters were back calculated to fit Conventional load deflection curves Parameters fit within a range of field and lab tests results
11
ASTM D 1143 Test Frame Test Pile Reinforcing Bars Wooden Planks Subsurface Soils Dial Indicators (deformation) Load Cell (Load) Ca
12
RLT Procedure 25,000 kg mass dropped on pile from varying heights Deflection Measured @ Point of Impact Force applied to pile top for 200-ms duration Energy transmitted to pile via anvil and dampened via springs Springs recoil and push load up to unload pile
13
FUNDEX-PLT BLACK BOX TEST SETUP RLT Equipment
14
Hydraulic Clamp 25,000 kg mass Damping Springs Test Pile Anvil Subsurface Soils Black Box Data Rec. RLT Procedure
15
RLT Load Application
16
Rate of Loading Ladd 1974 & Graham 1983 S u /(S u for =1%/hr)=1.0+0.1*Log s Where: S u = Undrained shear strength s= Strain The resulting loading rate for the RLT is: 3.6X10 6 Percent/Hour. Therefore SI for Cohesive soils is 1.7
17
Davisson Method - Pile Capacities Plot Load versus Deflection Plot pile elastic shortening line Compute offsett =0.15+0.1(B/12) Plot line parallel to elastic shortening line Compute pile capacity form curve
18
Theoretical Pile Capacities NAVFAC 7.2 Input parameters: –K hc =1.5 K ht =0.75 =0.75 –E p,=4.415E6-psiC p,=0.03 s =0.33 Total Elongation: t = p + fric. Total Settlement: t = p + fric. + tip
19
Uplift Test Analysis & Results
20
Summary of Results
21
RLT & Theory
22
Numerical Modeling - FLAC FLAC – 2D Finite Difference Model Cohesion parameter from CU Triaxial Mohr Coulomb Model Pile Element to model 16-inch square pile Soil pile interaction parameters calibrated to uplift Test then soil pile stiffness parameters were increased by a factor of 2 for RLT simulations Sinusoidal Loading function applied at pile head to simulate RLT
23
FLAC – Cohesion Block Values y x Cohesion in PSF
24
FLAC - Y-Displacement Contours Apply tension load till equilibrium y x Contours in Feet
25
FLAC – RLT Simulation SI=1.0 y x Load (Pounds) Deformation (Ft) 4.2-inches @ 800,000 lbs 2.2-inches @ 700,000 lbs Cohesion parameter same as Triaxial Test Results
26
FLAC – RLT Simulation SI=1.5 y x Load (Pounds) Deformation (Ft) 1.4-inches @ 800,000 lbs Cohesion parameter 1.5 times Triaxial Test Results
27
FLAC – RLT Simulation SI=2.0 y x Load (Pounds) Deformation (Ft) 1.0-inches @ 800,000 lbs Cohesion parameter 2.0 times Triaxial Test Results
28
RLT & FLAC
29
CONCLUSIONS Classical theoretical values deviate from observed data at higher loads RLT capacity results were about 2.0 X higher than the theoretical values A 1.7 X Strength Increase correlates well with published data Dynamic nature of the RLT mimic seismic conditions
30
CONCLUSIONS (CONT.) Designer could test several piles per day with RLT in cohesive material calibrate material parameters to match the observed data and then apply strength reduction to “Calibrated” parameters and establish “Ultimate Pile Capacities” Lower Factor of Safety could be applied to the “Allowable Pile Capacity”
31
CONCLUSIONS Classical theoretical values deviate from observed data at higher loads RLT capacity results were about 2.0 X higher than the theoretical values A 1.7 X Strength Increase correlates well with published data Dynamic nature of the RLT mimic seismic conditions
32
Richmond BART and UCSF Mission Bay
33
BART RLT
37
UCSF - Test 19A #5 - Davisson
38
UCSF - Test 19A #3 - Davisson
40
UCSF - Test 19A #5 - Davisson
41
UCSF - Test 19A #5 – Chin-Konders - 1
42
UCSF - Test 19A #5 Chin-Konders-2
43
UCSF - Test 19A #5 – Hansen - 1
44
UCSF - Test 19A #5 – Hansen 2
45
UCSF - Test 19A #3 – De Beers
46
N4 West
50
Classical and Finite Difference Method to Estimate pile Capacity Compared With Pile Load Test Results Yogesh Prashar, P.E., GE Force Pulse Conference, DFI January 2012 Oakley, California www.m2consultantsinc.com
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.