Download presentation
1
Atlas Copco Compressors LLC
Introduction – IT4 Scott Ellinger NOTES
2
EPA Tier 4 Regulations Focused on Reducing PM & NOx emissions
Two-Phase Introduction: INTERIM & FINAL Focused on Reducing PM & NOx emissions Introduction Timing varies by HP Band US, Canada, EU & Japan will be Broadly Aligned
3
Construction and Ag - 2012 75 -751 HP Engines 2 4 4 2 4 3 2
Unregulated Tier 1 / Stage I Tier 2 / Stage II Tier 3 / Stage IIIA Tier 4 Interim / Stage IIIB Tier 4 Final / Stage IV
4
EPA Mobile Tier 4 Nonroad Standards
(1) Compliance with optional ‘Option 1’ 0.30 g/kW-hr PM limit in 2008 allows 1-year delay of T4 until 2013. Option 1 engines in 2008 are T4i engines, not T3 engines.
5
Tier 4 Challenge Tier 4 Final brings a 90% reduction in emissions compared to Tier 3 Achieving near zero emissions by 2014 6.8 Tier 1 / Stage 1 (1996) Tier 1 / Stage 1 (1996) Representative of most stringent emission levels: hp ( kW) 4.8 NOx g/hp-hr Tier 2 / Stage II (2001) Tier 2 / Stage II (2001) 3.0 Tier 3 / Stage IIIA (2005) Tier 3 / Stage IIIA (2005) 45% lower 1.5 Tier 4 Interim / Stage IIIB (2011) 90% lower 0.3 Tier 4 Final / Stage IV (2014) 0.015 0.15 0.4 PM g/hp-hr 90% lower
6
Emissions & EPA Compliance
7
Achieving ‘Near-Zero’ Emissions
Emissions from 25 x Tier 4 Final machines will be equivalent to just 1 x Tier 1 machine Cummins Confidential
9
Terms and Key Words – IT4 Applications
Regeneration: The process of eliminating built up soot from the exhaust system Two types of Regeneration Active Regeneration: Using a hydrocarbon (fuel) to elevate exhaust gas temperatures above 1100 F in order to remove built up soot from the exhaust filter Passive (Natural) Regeneration: Using temperature alone to burn soot by elevated exhaust temperature Can be controlled by temperature management of the exhaust stream Can be achieved by maintaining exhaust gas temperature Can also be achieved by control valves that effect exhaust backpressure At some point Active Regeneration must be used
10
Terms and Key Words – DOC and DPF
Diesel Particulate Filter (DPF) Diesel Oxidation Catalyst (DOC)
11
Diesel Oxidation Catalyst (DOC)
Open cell substrate flow though device Reduces HC and CO significantly Reduces Pm 10 to 30% Converts NO to NO2 for passive regeneration of the DPF Oxidizes HC (diesel fuel) as part of active regeneration strategy No servicing required Requires use of low sulfur diesel or ULSD Typically element is ~100% of engine displacement in size
12
Diesel Particulate Filter (DPF)
Wall flow, high filtration efficiency (>95%) Traps ash, soot and any particles Needs periodic regeneration / cleaning Periodic ash cleaning required No muffler required in the vast majority of applications
13
Regeneration Active Regeneration
Particulate matter left in the filter system is burned off extending the lifetime of the filter. Uses a fuel burner in the exhaust stream that intermittently raises the temperature above 600°C (1112°F) Converts particulate matter to CO2 & Ash.
14
Terms and Key Words Soot
Incomplete combustion of hyrdocarbons in the exhaust stream Can be purged from the DPF by re-generation Ash Incomplete combustion of some hydrocarbon by-products CANNOT be purged from the DPF by re-generation EPA Mandated that DPF must withstand 4500 hrs before ash cleaning is needed HPCR High pressure common rail fuel system System pressures up to 30,000 psi Allows mulitple injection events to take place reduce emmisions VGT Variable Geometry Turbocharger Inlet guide vanes can adjust to provide exact boost pressure to work in conjunction with the EGR
15
Terms and Key Words ULSD Low ash Engine oil
Ultra low sulfur fuel (less than 15 ppm) Must be used on all IT4 machines Normal diesel fuel will kill an EGR and DOC within a few tank fulls Low ash Engine oil Must be used on all IT4 machines to reduce the formation of ash accumulating in the DPF CANbus – Method of communication between controllers or networks. All of Atlas Copco controllers use SAE J1939 Can communication
16
Emissions & EPA Compliance - EGR
EGR: Exhaust Gas Recirculation Exhaust gases are cooled and injected back into the engine cylinders to reduce NOx. Result: Lower peak combustion temperature generates less NOx but more particulate matter Heat rejection to radiator increases
17
Interim Tier 4 PowerTech Plus Technology
HC (fuel) Injection DOC DPF Exhaust Gas Cooled Air from Intercooler Variable Geometry Turbocharger (VGT) Air Inlet EGR Cooler EGR Valve NOx reduction with additional cooled EGR – building on Tier 3 PT+ VGT turbocharger Larger EGR cooler and valve Hydrocarbon (HC) and some Particulate Matter (PM) control with Diesel Oxidation Catalyst (DOC) Majority of PM reduction via Diesel Particle Filter (DPF) Active Regeneration System for DPF Compressed Air from Turbocharger
18
Regeneration Stratagy
19
DPF Regeneration ECU controls active regeneration
Diesel fuel added to system for 10 minutes every 5 to10 hrs Raises temperature into DPF to ~600°C (~1112°F) Soot Level
20
Exhaust Filter Cleaning & Maintenance
Designed for extended maintenance free operation but ash accumulation does occur. Minimum maintenance interval for ash removal, as defined by the EPA, is 4500 hours. This service interval can be increased depending on duty cycle DPF must be removed from unit and placed in specialized equipment for cleaning by a John Deere service technician. John Deere has set up a remanufactured filter program where the user buys a remanufactured filter & gives the core to the dealer/service center for cleaning.
21
DPF Information - Indicators
22
Exhaust Filter Cleaning & Maintenance
Several ways to extend service intervals Reduce idle time Enable auto cleaning Operate in high load condition when possible Use only Ultra low sulfur diesel fuel Use only approved low ash oil
23
Other IT4 items Preheat is controlled by John Deere without any control or parts from our side Engine contains the relay, fuse, and all necessary wiring to the glow pugs Preheat timing amount is a function of the fuel temperature Timing is calculated by the engines ECU All exhaust piping is Stainless steel Exhaust piping wrapped with insulation Exhaust bellows can be leakage points and should be occasionally inspected for distortion
24
Contact Numbers Main Number Atlas Copco Technical Support
Option 3 Clayton Jones - Hurricane Boosters/Compressors - Supervisor direct & mobile Andrew Stevenson – Compressors: Low Pressure direct & mobile Will Hudson – Generators/Compressors Ext & mobile Andrew Calendar – Compressors: High Pressure direct & mobile Jon Monaco - Hydraulic Att./Handheld Tools Ext & mobile Brandon Dyer – Compressors: Low Pressure/Hydraulic Att. direct & mobile Scott Ellinger – Compressors direct & mobile
25
Committed to Sustained Productivity.
25 NOTES