Presentation is loading. Please wait.

Presentation is loading. Please wait.

Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

Similar presentations


Presentation on theme: "Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University."— Presentation transcript:

1 Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University

2 Knowledge is Power Sir Francis Bacon (1561-1626)

3 Nuclear Knowledge can be the Power of Peace Happiness Fear Frustration

4 ●Uranium 90% (HEU) ●Pu-239 93% (WGPu) ●26 kg HEU / 5kg WGPu ●11 cm / 6 cm box

5

6 Muon Tomography(MT) 2.3mrad 10mrad 20mrad ~1.1° ~GeV Muon 1/cm 2 /min waterFeW 10cm

7 MT Station Examples Los Alamos (2003): Drift Tubes Science and Global Security 16 (2008) 37–53 INFN : CMS Muon Barrel Chambers Nucl. Inst. and Meth. A 604 (2009) 738-746. FIT : Triple GEMs Nucl. Inst. and Meth. A 652 (2012) 16-20

8 Requirements of Detectors for MT Large Area (~1m 2 ) High Detction Efficiency (>90%) High Spatial Resolution (<1mm) Cost-effective

9 RPC Resistive Plate Chamber –R. Santonico(in 1980s) Large Area Good Time Solution ~1ns Acceptable Spatial Resolution –~1cm CMS Muon Trigger RPCs by PKU (2002)

10 -HV HV Graphite Resistive Plate Working Gas Resistive Plate Gruand Graphite Readout Strips RPC Brief View

11 Combination of RPC & Delay-line Readout 90% F134a+9% C 4 H 10 +1% SF 6 50ml/Min

12 Avalenche Signal General Properties: Signals Avalenche +Streamer Signal

13 General Properties: Detection Efficiency

14 -HV

15 Streamer Profile Sigma 7.4 ± 0.2mm Avalanche Profile Sigma 2.2 ± 0.1mm Simulation Profile Sigma 2.40mm

16 Spatial Resolution Measurement Residual Method ΔX=X 2 -(X 1 +X 3 )/2

17 Spatial Resolution of Glass RPCs

18 Uniformity -50mm~-25mm Res=0.99 mm -25mm~0mm Res=0.89 mm 0mm~25mm Res=0.82 mm 25mm~50mm Res=0.94 mm

19 X Y and T readout in ONE RPC

20 X axis 0.79 mm (FWHM) for one RPC Y axis 1.97 mm (FWHM) for one RPC Preliminary

21 MT Station with three 2D-Glass RPCs 12+2 channels RPC 1 RPC 2 RPC 3 Material

22 Imaging Result: Empty target Empty target Mean angle ~15 mrad –Position/Alignment error ~8 mrad –RPC box, framework ~10 mrad Preliminary

23 Imaging Result: Pb brick 1 Pb brick 1 15cm*5.5cm*3.5cm Preliminary

24 Imaging Result: Pb brick 2 Pb brick 2 24cm*7cm*6cm Preliminary

25 Conclusions Glass RPCs with LC Delay-line Readout –Simple structrue, stable performance –Efficiency 95~98% –Charge profile measurement <1mm(FWHM) in avalenche mode –Ideal detectors for MT MT Station using three 2D-Glass RPCs –Preliminary Test (detection area: 20cm*20cm) –Sensitive to ~cm Pb

26 MT station with 4 RPCs 3D Imaging Coming Soon

27 Thank You! Email: Liqt@pku.edu.cn Gmail: Liqt1985@gmail.com Supervisor: Prof. Yanlin Ye Email: yeyl@pku.edu.cn Peking University, China