XAS 375 JD6 Compressors Scott Ellinger
Committed to sustainable productivity
2
Technical Specifications - XAS 375 JD6
3
Technical Specifications - XAS 375 JD6 (2)
4
Technical Specifications - XAS 375 JD6 (3)
5
Flow summary XAS 375 JD6
6
AIR SYSTEM INLET VALVE Spring loaded in the ready position
Control Air closes the inlet Also serves as check valve
7
No-Load Condition Load Condition
8
Unload Condition Blow- Down Condition
9
REGULATING VALVE Spring loaded Adjusting receiver pressure by changing spring tension to pressure gauge and loading valve to speed regulator to unloading valve Regulating pressure: Receiver pressure In order to regulate the pressure inside the reciever tank of our compressor, the air intake and the engine speed have to be controlled. This is done pneumatically. For that reason, we need regulating pressure. The regulating valve reduces the pressure inside the tank, thus providing the regulating pressure. This regulating pressure is then supplied to the unloader valve and the speed regulator or RPS. The air receiver pressure can be set to another value by adjusting the spring tension of the regulating valve. This is done by turning the handle on top the valve. Increasing the spring tension, by turning in, will increase the regulating pressure and consequently the pressure inside the vessel. Turning out will decrease the pressure.
10
AIR SYSTEM MINIMUM PRESSURE VALVE
Maintains a minimum pressure of 58 PSI for oil flow Also contains the final check valve
11
Control Panel
12
XC 2002 Controller
13
XC2002 Controller Overview
14
XC 2002 Control Module
15
XC 2002 - Menus *Password is 2003*
On newer units Parameters are under Extra Views. *Password is 2003*
16
XC 2002 Controller – 1.200 Program
17
XC 2002 Controller – 1.200 Program
Automatically loads “with use of in line micro switch” Automatically unloads unit “unit will not reload” Service Timer 1 = 500hrs Service Timer 2 = 1000hrs “On” lets you connect to engine with machine not running
18
XC 2002 Controller – 1.200 Program
19
XC 2002 Controller – 1.200 Program
20
XC 2002 Controller – 1.200 Program
21
XC 2002 Controller – 1.200 Program – Unit Type 2
22
Event Logging
23
J1939 Canbus Engine Communication
24
XC2002 Service Timer Reset Scroll through the controller menu to “Parameters” (on some units “Parameters” may be a submenu under “Extra Views”) Press Enter to select Parameters Scroll to ST1 Reset or ST2 Reset as needed (ST1 = 500 hours, ST2 = 1000 hours) Press Enter to select to reset the appropriate timer Center option will highlight; scroll to highlight “Yes” and press Enter Change Password to 2003 and press Enter Service timer is reset
25
Engine Fault Code List
26
Engine Fault Code List
27
Engine Fault Code List
28
Engine Fault Code List
29
Engine Fault Code List
30
Engine Fault Code List
31
Engine Fault Code List
32
Engine Fault Code List
33
Engine Fault Code List
34
Displaying of J1939 DM1 Alarms
35
Wiring Schematic – XAS 375 JD6
Canbus terminator resistor p/n
36
Legend
37
John Deere – Tier III – RPS in place of Pneumatic Speed Regulator
Regulating Pressure Sensor “Speed Sensor”
38
Preheat Relay K1 Controlled by JDEC
Starter Relay
39
Preventive Maintenance Filter Kits – XAS 375 JD6
40
Spare Parts Recommendation
41
Contact Numbers Main Number Atlas Copco Technical Support
Option 3 Clayton Jones - Hurricane Boosters/Compressors - Supervisor direct & mobile Andrew Stevenson – Compressors: Low Pressure direct & mobile Will Hudson – Generators/Compressors Ext & mobile Andrew Calendar – Compressors: High Pressure direct & mobile Jon Monaco - Hydraulic Att./Handheld Tools Ext & mobile Brandon Dyer – Compressors: Low Pressure/Hydraulic Att. direct & mobile Scott Ellinger – Compressors direct & mobile
42
Committed to sustainable productivity.