1 /10 FIRELEC Migration Solution This document and the information therein are the property of FIRELEC and shall not be copied or communicated to a third party without the prior written authorization of FIRELEC 1 Don't let wiring costs prevent you from upgrading an ABB « Fischer and Porter System 6 » to a DeltaV TM system

2 /10 The ITB Migration Adapters (ADP-ITB) allow to connect easily, existing Fischer and Porter System 6 FTAs to DeltaV I/O cards keeping in place : the existing I/O panels (ITBs) the existing associated I/O cables the existing loop power supplies connected on the FTAs Fischer and Porter System 6 > DeltaV Using ADP-ITB (Migration Adapters) This document and the information therein are the property of FIRELEC and shall not be copied or communicated to a third party without the prior written authorization of FIRELEC 2 New DeltaV System ITB and cable to be kept I/O Board (IOB) to be removed No impact on the field wiring No need for loop check FMS-DCI6-DV-1

3 /10 Existing 19 inches rack, IOBs, power supplies and communication cards to be removed Existing architecture This document and the information therein are the property of FIRELEC and shall not be copied or communicated to a third party without the prior written authorization of FIRELEC 3 Process I/Os Existing ITBs (DI,DO) Existing ITBs (AI,AO) CNRTL & I/O Rack 19 inches Height : 10U Existing cable tray 19 inches, Height : 1U ITBs and I/O cables stay in place in the existing cabinets Process I/Os stay in place in the existing cable trays FMS-DCI6-DV-1

4 /10 ITBs and I/O cables stay in place in the existing cabinets Process I/Os stay in place in the existing cable trays This document and the information therein are the property of FIRELEC and shall not be copied or communicated to a third party without the prior written authorization of FIRELEC 4 New architecture for A.loop or P.loop replacement BC11007 with ADPs Rack 19 inches Height : 3U Process I/Os Existing ITBs (DI,DO) Existing ITBs (AI,AO) Existing cable tray 19 inches, Height : 1U FMS-DCI6-DV-1

5 /10 New architecture for D.loop or D.Output replacement This document and the information therein are the property of FIRELEC and shall not be copied or communicated to a third party without the prior written authorization of FIRELEC 5 2 x BC11007 with ADPs Rack 19 inches Height : 2 x 3U = 6U ITBs and I/O cables stay in place in the existing cabinets Process I/Os stay in place in the existing cable trays Process I/Os Existing ITBs (DI,DO) Existing cable tray 19 inches, Height : 1U Lower connector Upper connector FMS-DCI6-DV-1

6 /10 New architecture for A.Input or A.Output replacement This document and the information therein are the property of FIRELEC and shall not be copied or communicated to a third party without the prior written authorization of FIRELEC 6 Existing cable tray 19 inches, Height : 1U 2 x BC11007 with ADPs Rack 19 inches Height : 2 x 3U = 6U ITBs and I/O cables stay in place in the existing cabinets Process I/Os stay in place in the existing cable trays Process I/Os Existing ITBs (AI,AO) Lower connector Upper connector FMS-DCI6-DV-1

7 /10 New DeltaV architecture This document and the information therein are the property of FIRELEC and shall not be copied or communicated to a third party without the prior written authorization of FIRELEC 7 The new DeltaV controllers and I/O cards (M or S series) are installed The I/O files BC11007 are installed in place of the existing Fischer and Porter System 6 Files where the IOBs were previously installed The ADP-ITBs are installed in the new files BC11007 Secondary DeltaV Area Control Network Cntrl PS I/O1 I/O2 I/O3 I/O4 I/O5 I/O6I/O7 I/O8 Primary DeltaV Area Control Network Cntrl PS I/O9 I/10 I/11 I/12 I/13 I/14I/15 I/16 Existing ITBs (DI,DO) Existing ITBs (AI,AO) AI AO DI DO The new FIRELEC I/O cables are installed between ADP-ITBs and new DeltaV I/O cards (M or S series) FMS-DCI6-DV-1

8 /10 This document and the information therein are the property of FIRELEC and shall not be copied or communicated to a third party without the prior written authorization of FIRELEC 8 Compatibility table IOB (Input/Output Board) : The board which is to be removed FTA (Field Termination Assembly) : The I/O panel where the I/Os are connected, and which is kept Firelec Adapter : The migration adapter to be installed in BC11007 (new I/O file) to perform I/O migration and process signal spliting toward the DeltaV system I/O cards. FMS-DCI6-DV-1

9 /10 Advantages This document and the information therein are the property of FIRELEC and shall not be copied or communicated to a third party without the prior written authorization of FIRELEC 9 The main advantages of the FMS-DCI6-DV-1 (ADP-ITBs) for Fischer and Porter System 6 migration are as follow : Existing I/O cables are just disconnected from the Fischer and Porter System 6 I/O boards and reconnected to the ADP-ITBs keeping in place the FTAs and associated I/O cables The existing loop drawings are kept without any modification, allowing all maintenance processes and procedures to remain unchanged. FMS-DCI6-DV-1

10 /10 Contacts This document and the information therein are the property of FIRELEC and shall not be copied or communicated to a third party without the prior written authorization of FIRELEC 10 For more information and support : Roel C.Mulder Director System Migration & Modernization Europe E-mail : Roel.Mulder@Emerson.com Phone : +31(0)70 413 67 18 Wilfrid DUPAS Sales Director E-mail : wilfrid.dupas@firelec.com Phone : +33 (0)470 590 550 FMS-DCI6-DV-1