Download presentation
Presentation is loading. Please wait.
1
Ultrasound Computed Tomography 何祚明 陳彥甫 2002/06/12
2
Introduction Conventional X-ray image is the superposition of all the planes normal to the direction of propagation. The tomography image is effectively an image of a slice taken through a 3-D volume. An estimated 10-15% of breast cancers evade detection by mammography. Poor differentiation of malignant tumors from highly common cysts (while ultrasound can do so with accuracies of 90-100%). UCT can provide not only structural/density information, but also tissue compressibility and speed of sound maps
3
Tomography Time of flight or intensity attenuation Array transducer D data (only t f ) Rotation : 2-D data (t f on range and angle ) Scan : 3-D data (y position, t f and angle ) A B
4
Tomography R A reconstruct
5
Reconstruction Method Attenuation method Iterative method –Algebraic Reconstruction Technique (ART) Direct reconstruction –Fourier transform Alternative direct reconstruction –Back projection –Filtered back projection
6
Central Section Theorem f (x,y)g 90 (y’) x y y’
7
Ambiguity Angle f(x,y) x y R xcos + ysin = R
8
Equations 1D FT of projection function 2D FT
9
Cont’d 2D Fourier transform (u,v) in polar coordinates is ( co s , sin ) 2 D inverse Fourier Transform
10
f(x,y) x y R u v g (R) G()G() Figures
11
Algorithm solve coordinate problems (polar to rectangular coordinates) 1.1D FT each of the projections g (R) G ( ) 2.Integrate G ( ) in and -- avoid coordinate transformation problems g (R) G ( ) =F(u,v) f (x, y) 1D FT
12
Back Projection Reconstruction Back projection (at one angle) Integration of all ambiguity angle
13
Cont’d Drawback of back projection method So, we integrate this function after added 1/
14
Disadvantage FT{1/ 1/r : blurring function f (x,y) convolves 1/r Additional filter is needed x yyy xx 1/r objectBackprojected object
15
Filter Design Design filter at spatial frequency domain Cone filter Spatial filter u v 1/r
16
Signal Processing Flow Backprojection all angles, g (R) F b ( ) Forward 2D FT to get: Apply filter on to get F (u,v) Inverse 2D FT to f (x,y) Fb()Fb() F(u,v)f (x, y) 2D FT2D IFT g (R) Filtering
17
Algebraic Reconstruction Technique (ART) The iterative process starts with all values set to a constant, such as the mean or 0. At each iteration, the difference between the measured projection data for a given projection and the sum of all reconstructed elements along the line defining the projection is computed. This difference is then evenly divided among the N reconstruction elements.
18
Algebraic Reconstruction Technique (ART) 1.Projection Step 2.Comparison Step 3.Backprojection Step 4.Update Step Additive ART :Multiplicative ART :
19
Algebraic Reconstruction Technique (ART) N elements per line f ij (calculated element) cross section g j (measured projection)
20
Simulation Results I. Using ART to reconstruct : Simulated DataReconstruction Result 102030405060708090100 10 20 30 40 50 60 70 80 90 100 102030405060708090100 10 20 30 40 50 60 70 80 90 100
21
Simulation Results I. 102030405060708090100 10 20 30 40 50 60 70 80 90 100 Simulated Data 1020304050607080 10 20 30 40 50 60 70 80 Reconstruction Result Using direct Fourier transform to reconstruct :
22
Simulation Results II. Using ART to reconstruct : Reconstruction ResultSimulated Data 102030405060708090100 10 20 30 40 50 60 70 80 90 100 102030405060708090100 10 20 30 40 50 60 70 80 90 100
23
Simulation Results II. Reconstruction ResultSimulated Data 102030405060708090100 10 20 30 40 50 60 70 80 90 100 5101520 2 4 6 8 10 12 14 16 18 20 Using direct Fourier transform to reconstruct :
24
Experiment Architecture Transducer Phantom Transducer y x Water Tank Transmitter Receiver 2 mm/step 2 degrees/rotate
25
Experiment Architecture
26
Breast Phantom
27
Eraser Phantom
28
Rubber Ball
29
Time-of-flight t1t1 t2t2 t1t1 t2t2 t3t3 t3t3
30
Reconstructed Image Breast phantom 1020304050607080 10 20 30 40 50 60 70 80 ARTDirect Fourier Transform 1020304050607080 10 20 30 40 50 60 70 80
31
Reconstructed Image Breast phantom, using ART 1020304050607080 10 20 30 40 50 60 70 80
32
Reconstructed Image Rubber ball 2468101214161820 2 4 6 8 10 12 14 16 18 20 5101520 2 4 6 8 10 12 14 16 18 20 ARTDirect Fourier Transform
33
Reconstructed Image Eraser 510152025303540 5 10 15 20 25 30 35 40 510152025303540 5 10 15 20 25 30 35 40 Direct Fourier TransformART
34
Conclusions ART reconstruction is much faster than other reconstruction method but must notice the velocity profile normalization. Direct fourier reconstruction is effective but less efficiency. Backprojection reconstruction needed additional filter to cancel integration errors.
35
Future Works Correct velocity profile estimation Discuss backprojection method errors and additional filter design method Discuss diffraction errors in ultrasound
36
References [1] Albert Macovski, “Medical Imaging Systems” [2] Matthew O’Donnell, “X-Ray Computed Tomography (CT)”, University of Michigan [3] Douglas C. Noll, “Computed Tomography Notes”, University of Michigan, 2001 [4] Brian Borchers, “Tomography Lecture Notes”, New Mexico Tech., March 2000 [5] James F. Greenleaf et al., “Clinical Imaging with Transmissive Ultrasonic Computerized Tomography”, IEEE trans.on Biomedical Engineering vol. 28 no. 2 1981