NIRCam has Two Imagers in Two Modules
Two adjacent fields of view (2.2 arcminute)2 Both fields in SW and LW bands Two back-to-back modules TIPS 4/18/2013
5
Fields of View of JWST Instruments
-2 -4 2 4 -6 -8 6 8 Horizontal Field Position (arcmin) Vertical Field Position (arcmin) NIRSpec NIRCam MIRI NIRISS FGS TIPS 4/18/2013
6
The Near Infrared Camera
2 functionally identical (mirror image) modules 2 channels in each module: Short Wavelength ( m) Long Wavelength ( m) HgCdTe FPA Format (22) (2040 2040) 1 (2040 2040) 0.032 arcsec/pixel 0.065 arcsec/pixel FOV= 2.212.21 arcmin2 Filters provide (W R=4, M R=10, N R=100) Sensitivity (10, R=4, 104 s): 1.1 m: 10.4 nJy 2.0 m: 12.1 nJy 4.4 m: 24.5 nJy Coronagraphic masks: TIPS 4/18/2013
7
NIRCam Optical Layout TIPS 4/18/2013
8
Assembled Modules TIPS 4/18/2013
9
NIRCam Filter Wheel TIPS 4/18/2013
10
NIRCam Optical Elements
TIPS 4/18/2013
11
NIRCam Focal Plane Arrays
TIPS 4/18/2013
12
MULTIACCUM Readout Mode
(“ramp”) (“ramp”) TIPS 4/18/2013
13
Detector Performance TIPS 4/18/2013
14
NIRCam Sensitivity Comparison
Ground SST HST JWST NIRCam Galaxy models: 5-sigma, 50,000 secs microns TIPS 4/18/2013
15
NIRCam Coronagraph - 1 TIPS 4/18/2013
16
NIRCam Coronagraph - 2 TIPS 4/18/2013
17
NIRCam’s Wavefront Sensing Role
First Light NIRCam provides the imaging data needed for wavefront sensing. Dispersed Hartmann Sensors at 0° and 60° orientations permit phasing of adjacent mirror elements. Two grisms on the long wavelength channel provide an alternative to the Dispersed Hartmann Sensor (DHS). After segment capture Coarse phasing w/DHS Spectra recorded by NIRCam DHS at pupil Fine phasing After coarse phasing Fully aligned TIPS 4/18/2013
18
NIRCam Status Cryovac 3 successfully finished April 11.
Instrument currently in bake out to meet contamination requirements. ICE rebuilding underway. EMI testing is next. Shipment to GSFC expected at end of May. Acoustic and vibe testing (at APL?) in June. ICE boxes arrive late August. FPE delivered in September. Acceptance review at GSFC in October. New SW FPAs are in house at UofA, and they look beautiful. Expect to prepare these and place in NIRCam before ISIM CV2. New LW FPAs ready at Teledyne. Hope to prepare these too. TIPS 4/18/2013