Download presentation
Presentation is loading. Please wait.
Published byPosy Walker Modified over 9 years ago
1
Improvement of indirect slumping technology by using a pressure frame Mingwu Wen, Laura Proserpio, Peter Friedrich Max-Plank-Institute for Extraterrestrial Physics Max-Planck-Institute for Extraterrestrial Physics (MPE) December 09,2015
2
New mouldsTest in vacuum Test with pressure frame INTRAAST project (with HAB) Integration facility improved prototypes JIM module ( with INAF- OAB) JIM in PANTER vibration tests entrapped air ?
3
Max-Planck-Institute for Extraterrestrial Physics (MPE) December 09,2015 CeSiC mould D263 glass Pumping system Pressure frame Before slumping The electric oven in MPE with pumping system Mould CeSiC Concave Wolter I shape (PAR+HYP) 160 mm x 260 mm CTE: 2.4 x 10 -6 m/(mK) Glass Schott D263 290 x 190 x 0.55 (0.4) mm 3 Tannealing 557°C CTE: 7.2 x 10 -6 m/(mK) Pressure frame Steel CTE: 13.0 x 10 -6 m/(mK) SLUMPING LABORATORIES and TOOLS @ MPE
4
Max-Planck-Institute for Extraterrestrial Physics (MPE) December 09,2015 After slumping SLUMPING LABORATORIES and TOOLS @ MPE Metrology facility: 3D high precision measuring table equiped with optical sensor optical sensor 600 µm measuring range 20 nm resolution in z glasses kept in place on a 3-points support, gravity effect as derived by FEM subtracted Correction of T-variation effect CHR on lpkf 3-points support glass Optical sensor z
5
Max-Planck-Institute for Extraterrestrial Physics (MPE) December 09,2015 Gravity correction Measured shape Dim. : 200 mm x 100 mm x 0.55 mm Range: -20µm to 4 µm Shape variation caused by gravity using 3-points support
6
Max-Planck-Institute for Extraterrestrial Physics (MPE) December 09,2015 Temperature-variation correction T-variation Z-variation scan direction T-variation effects are subtracted for long time scan.
7
Max-Planck-Institute for Extraterrestrial Physics (MPE) December 09,2015 Application of pressure PF7 PF10 PF9 PF8 PF11 PF12 PF6 Annealing T T max Group 1: Effect of Cleaning Group 2: Effect of pressure time, glass thick.:0.55mm Group 3: Effect of glass thickness glass thick.:0.40mm
8
Max-Planck-Institute for Extraterrestrial Physics (MPE) December 09,2015 Group 1 : Cleaning Focal length:7500.00 mm Radius: 374.157 mm Alpha: 0.7132° Nominal parameters of the mould Cleaning improved Middle frequency errors are reduced with better cleaning New long scale errors are introduced PF test 6PF test 7
9
Max-Planck-Institute for Extraterrestrial Physics (MPE) December 09,2015 Group 2,3 : Pressure time and glass thickness Z: - 50 µm ~5 0 µm PF7 PF8 PF9 PF10 PF11 PF12 The long scale error increased with longer pressure time especially in the central part of the glasses
10
Max-Planck-Institute for Extraterrestrial Physics (MPE) December 09,2015 Fitted radius of the mirrors Fitted focal length of the mirrors 7 PF7PF8PF9PF10 PF11 PF12 PF7PF8PF9PF10 PF11 PF12
11
Max-Planck-Institute for Extraterrestrial Physics (MPE) December 09,2015 D263 glass CeSiC mould Pressure frame Kink getting stronger with longer pressure time shrink Long-time pressure PF8 PF10 Further work… Optimize the gap to decrease the kink Improve the cleaning Improve the thermal cycle curve Thanks! gap
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.