First analysis results of EXT MW0-4 X,Y,- 10,-10 wire-size measurements to reconstruct the 4D betatron phase-space
2
Questions opened by the First analysis results of EXT MW0-4 X,Y,- 10,-10 wire-size measurements to reconstruct the 4D betatron phase-space
3
1-Principle
4
Coupling Measurements: waist scan method - 1 Transfer Matrix: normal quad: R tot = RQ skew quad: R tot = RQ K Coupling terms Measurable terms The squares of the measured beam sizes, 11 M, 13 M, 33 M, at a wire scanner position can be expressed as a parabolic function of the strength of the scanned quad, described by 3 fit parameters A, B, C: ij =A ij (k-B ij ) 2 +C ij 13 M can be measured using a tilted wire scanner, u (10 o ), applying method described in I. Agapov, G. Blair, M. Woodley, PRST-AB 10 112801 (2007) P. Emma, M. Woodley, ATF-99-04: where is the angle between x and tilted wires
5
Coupling Measurements: waist scan method - 2 With normal quad scan: With skew quad scan:
6
2-Measurements
7
- Measurements performed on 28th May 2009 by G.W., Y.R., M.W., F.Z. - Dispersion measurements and corrections - QK1X scans: at -20, -10, 0, 10, and 20 A, 3 measurements each time - MW0X: y, +10 o, -10 o - MW1X-MW4X: x, y, +10 o, -10 o MW1X_xMW2X_xMW3X_xMW4X_x -20132+/-1596+/-3163+/-784+/-4 -10145+/-8103+/-3167+/-881+/-1 0146+/-9102+/-11158+/-379+/-4 10152+/-13102+/-5163+/-779+/-5 20148+/-5108+/-12167+/-1084+/-2 MW0X_+10MW1X_+10MW2X_+10MW3X_+10MW4X_+10 -2040.0+/-4.743.6+/-2.321.9+/-5.350.2+/-1.346.6+/-0.3 -1033.0+/-2.542.2+/-1.127.1+/-2.148.6+/-2.433.2+/-2.4 044.4+/-3.847.8+/-2.032.2+/-2.744.4+/-4.213.5+/-1.0 1059.5+/-5.059.8+/-6.139.9+/-1.344.5+/-5.015.8+/-2.4 2078.5+/-2.676.5+/-3.650.2+/-3.437.8+/-1.532.9+/-0.6 MW0X_yMW1X_yMW2X_yMW3X_yMW4X_y -2026.7+/-1.917.7+/-0.722.8+/-0.911.9+/-0.320.5+/-0.7 -1016.2+/-0.813.9+/-0.920.9+/-1.38.4+/-0.38.4+/-0.1 019.0+/-0.916.4+/-1.028.5+/-1.46.9+/-0.49.2+/-0.3 1033.9+/-1.122.5+/-0.929.1+/-0.98.5+/-0.322.0+/-1.6 2052.8+/-4.735.1+/-3.339.0+/-3.48.7+/-0.434.9+/-1.2 MW0X_-10MW1X_-10MW2X_-10MW3X_-10MW4X_-10 -2021.9+/-0.721.6+/-0.636.1+/-3.616.1+/-0.76.6+/-0.2 -1010.9+/-0.718.8+/-0.820.7+/-1.216.6+/-0.66.5+/-0.6 013.4+/-2.715.5+/-0.922.2+/-2.420.3+/-2.714.7+/-0.3 1021.8+/-0.214.8+/-1.918.8+/-2.319.1+/-1.525.3+/-1.5 2031.9+/-3.420.6+/-2.031.2+/-1.422.3+/-1.332.6+/-2.6
8
3-First "difficulty"
9
The measurements we get from x and y are corrected from the moving 45 o axis, but not for +10 o and -10 o. Question: -How are oriented wire on each wire-scanners? Answer: the same for all the WS Beam direction Correction to apply to -10 o : cos(35 o ) With =80 o Correction to apply to +10 o : cos(55 o ) With =100 o
10
4- Graphical representation
11
x +10 o -10 o y MW0X MW1X MW2X MW3X MW4X
12
5- Coupling
13
From I. Agapov, G. Blair, M. Woodley, PRST-AB 10 112801 (2007), pp 8-9 Simple deductions - If the major axis of the beam lies along the horizontal axis =0 - if ≠0, then =cste with - if (80 o )= (100 o ) then =0
14
Coupling reconstruction applying MW1X MW2X MW4XMW3X from +10 o ( 100) and -10 o =80) measurements
15
Coupling reconstruction applying MW1X MW2X MW4XMW3X abs(1- + / - )
17
6- Questions 1 - Stupid mistakes from me... (after several verifications, no major bugs found) 2 - Are the named +10 0 and -10 0 wires invert / Was there an error in the positionning of the wires for the scan of the beam? 3 - Several other errors during data acquisition?.... 4 - other Test of 2
18
Coupling reconstruction applying from +10 o ( 100) and -10 o =80) measurements with inversion of named +10/-10 wires MW1X MW2X MW4X MW3X
19
7- Interpretations Coupling reconstruction applying inversion of +10/-10 wires Results should look like b1: 2 options: 1 - Consider b1 is true: +10 and -10 are invert + half of the data are "wrong" but what I mean by "true"? 2 - Should I believe this equation? fig. a fig. b
20
8- A bit of geometry
21
Are you agree with this? The tranverse profile of a gaussian beam can be represent by an ellipse of major axis x and minor axis y x =5 y =1
22
From I. Agapov, G. Blair, M. Woodley, PRST-AB 10 112801 (2007), pp 8-9 From P. Emma, M. Woodley, ATF-99-04
23
If no coupling, =0 o B A C
24
From P. Emma, M. Woodley, ATF-99-04 If no coupling, =0 o B A C A’ B’
25
From P. Emma, M. Woodley, ATF-99-04 If no coupling, =0 o B A C’ A’ B’ !!!??? C
26
What I know about an ellipse general equation: reduce equation: o xx r yy
28
But what do the wire scanners measure?: projections the tilted wires don’t measure the beam sizes, but the projection of r, such as: is maximal
29
But what do the wire scanners measure: projections
30
From P. Emma, M. Woodley, ATF-99-04 Is it the philosophy of this?
31
The measurements MW1X MW2XMW3X MW4X -20A -10A 0A 10A 20A