Download presentation
Presentation is loading. Please wait.
Published byShonda Cameron Woods Modified over 9 years ago
1
LAr1 Plans at FNAL Bruce Baller - Fermilab
2
Outline LAGUNA Meeting - Mar 20112 LBNE LAr detector overview Prototyping plan 1 kton prototype
3
LBNE, LArTPC, 300L – 800L Plan Ross Shaft Ramp From 300L to 800L Existing 800 Level Yates Shaft LArTPC Cavern 1 Existing 300 Level Kirk Portal LArTPC Cavern 2 Utility Shafts To Surface
4
LAGUNA Meeting - Mar 20114 Existing 800 Level Existing 300 Level Ross Shaft Access Ramp Access Portal Utility Shaft Access Portal, Cryogenics Building Cavern SITE PLAN
5
LAGUNA Meeting - Mar 20115 CR Veto Membrane Cryostat Mounting Rails Anode Plane Assembly (168) Cathode Plane Assembly (224) Field Cage 2.5m 7m
6
Cold Electronics LAGUNA Meeting - Mar 20116 Analog ASIC Tested
7
Reference Design - Key Parameters LAGUNA Meeting - Mar 20117 One detector module 2 high x 3 wide x 26 long = 168 Anode Plane Assemblies (APA) APA 3840 instrumented wires @ 3mm wire spacing (5mm?) Four wire planes: Grid, Induction 1, Induction 2, Collection 2.5m drift (3.5m?) 16.7 kton fiducial mass, 20 kton active mass, 25 kton total mass Heat load = 31 kW insulation + 12 kW electronics + 6(x4) kW LAr pump ~ 50 kW 0.5 MW power consumption (cooling!) Light detection system? - A “desirement” Two detector modules in one cavern – 34 kton Cavern 184m x 24m x 25m
8
Issues & Prototyping Plan LAGUNA Meeting - Mar 20118 Achieving argon purity without vacuum pumping Liquid Argon Purity Demonstrator (LAPD) Achieving argon purity in a membrane cryostat 3m x 3m wall panel Leak testing LAPD 35 ton prototype (purity monitors) Engineering and integration prototype 3 – 4 full scale APAs, 6 – 8 CPAs, field cage, full readout chain “1 kton prototype” = SBL LAr1 (Project Manager opinion) Electronics reliability 20 year lifetime design rules for150 m CMOS process, stress test
9
3m x 3m Membrane Cryostat Wall Panel LAGUNA Meeting - Mar 20119 Compare He sniffing and ammonia calorimetric leak checking Max p across membrane if we need to vac pump Under construction at Fermilab GTT visit next week Panel built at Samsung (Korea)
10
LAPD LAGUNA Meeting - Mar 201110 10’ dia x 10’ high SS tank 2x20cm, 2x50cm purity monitors, RTD’s Test in summer 2011
11
35 Ton Prototype LAGUNA Meeting - Mar 201111 3m x 3m x 3m membrane cryostat Use LAPD cryogenics system and instrumentation Side benefit: prototype cryostat procurement Engineering – Arup Procurement & Construction – Fermilab or construction management firm
12
“1 kton Prototype” Example LAGUNA Meeting - Mar 201112 11.5m 16m 1.2 kton LAr total 730 ton active 3.8m drift 6 kW cooling req’d DZero Ass’y Hall pit Use DZero calorimeter cryo system, ODH system Attractive site
13
LAGUNA Meeting - Mar 201113 DAB Pit 14m x 21m floor 18m depth
14
Prototype or Physics Experiment? My Understanding LAGUNA Meeting - Mar 201114 “Physics experiment rules” Fermilab: Experiment proposal approved by the director after consideration by the Physics Advisory Committee Time… DOE: Detector constructed using capital equipment funds if the cost exceeds $5M project management structure (CD-0, etc) Time & money… “Prototype rules” DOE: Constructed using R&D funds Under the aegis of the parent project A Utopian vision Fermilab constructs a LAr TPC test facility that just happens to be located in a neutrino beam
15
LAGUNA Meeting - Mar 201115LAr WG Mtg - Dec 201015 TPB Light detector – MPPC? Acrylic plate 460 nm 128 nm Doc 3303, “Demonstration of a Lightguide Detector for Liquid Argon TPC’s”, arXiv 1101.3013 Key result: Observe 7 – 8 pe from 5.3 MeV in LAr using a cryogenic PMT. (Expected 10 pe). 50 cm < attenuation length < 200 cm Backup Slide – Light Collection
16
Backup Slide – Veto Drifts LAGUNA Meeting - Mar 201116