A. Bross MICE CM17 February 2007 1 MuCool RF Program 805 and 201 MHz Studies
2
A. Bross MICE CM17 February 2007 2 RF Cavity R and D ANL/FNAL/IIT/LBNL/UMiss/Cockcroft
3
A. Bross MICE CM17 February 2007 3 MuCool Test Area Facility to test all components of cooling channel (not a test of ionization cooling) u At high beam power s Designed to accommodate full Linac Beam s 1.6 X 10 13 p/pulse @15 Hz – 2.4 X 10 14 p/s – 600 W into 35 cm LH 2 absorber @ 400 MeV u RF power from Linac (201 and 805 MHz test stands) s Waveguides pipe power to MTA
4
A. Bross MICE CM17 February 2007 4 MTA Hall
5
A. Bross MICE CM17 February 2007 5 MTA Hall Instrumentation 805 201 CsI Plastic Scintillator Magnet Chipmunk
6
A. Bross MICE CM17 February 2007 6 Fundamental Focus Of RF R&D Study the limits on Accelerating Gradient in NCRF cavities in magnetic field However u We believe that the behavior of RF systems in general can be accurately described (predicted) by s Tensile strength of the material(s) used in the cavity fabrication (T) Local surface field enhancements ( eq ) E surf = 2T/ / eq u This applies to all accelerating structures s In SC structures local heating becomes problem first u Follows universal curve
7
A. Bross MICE CM17 February 2007 7 805 MHz Data seem to follow universal curve u Max stable gradient degrades quickly with B field Remeasured u Same results u Does not condition Gradient in MV/m Peak Magnetic Field in T at the Window
8
A. Bross MICE CM17 February 2007 8 First RF 805 MHz Commissioning without Magnetic Field Last March
9
A. Bross MICE CM17 February 2007 9 First Radiation Measurement with Magnetic Field compared to No Field Data March 06, Results. Safe E Field Limit ~ 16MV/m Detector Distance=1.34 m
10
A. Bross MICE CM17 February 2007 10 Nov. 06 Results: Electric field limit at 2.5 T in the LBL Single Cell Cavity with Curve Be Windows coated with TiN
11
A. Bross MICE CM17 February 2007 11 Latest Electric field limit Data at 2.5 T and 1.25 T in the LBLSingle Cell Cavity with Curve Be Windows coated with TiN Asymptotic Gradient limit line at 1.25 T 2.5 T Data RF Conditioning without Magnetic Field The Asymptotic limit line shown indicates the continuous Gradient sparking limit. In all the cases studied including Lab G this line as predicted the Gradient Limit for the cases under Study. For the 1.25 T case the Save operating limit has been shown to be 20 MV/m 1.25 T Data
12
A. Bross MICE CM17 February 2007 12 Comparison of Lab G Results with the MTA Data MTA Result ~ 16 MV/m MTA 1.25 T Result Jan. 07
13
A. Bross MICE CM17 February 2007 13 805 MHz Imaging
14
A. Bross MICE CM17 February 2007 14 Next 805 MHz study - Buttons Button test u Evaluate various materials and coatings u Quick Change over
15
A. Bross MICE CM17 February 2007 15 RF R&D – 201 MHz Cavity Design The 201 MHz Cavity is now operating u New data on x-ray backgrounds will be presented
16
A. Bross MICE CM17 February 2007 16 X-Ray Detectors #16: NaI crystal (1.5” diameter × 2”), upstream of 201 cavity #8: large thick scintillator paddle, upstream of 201 cavity similar to MICE TOF (14” × 14.5” × 0.5”)
17
A. Bross MICE CM17 February 2007 17 Procedures X-ray background measurements u Recording x-ray events for 1000 rf pulses u Creating electronic gates to record x- ray events at rf envelope during fill, flattop, decay and total range of rf pulse. RF pulse length ~ 100-μs X-ray energy spectrum measurements u The histogram memory HM413 was calibrated with Co60 source u HM413 histogram memory was used to histogram the signals from AD413A ADC Note: there is cosmic-ray background for all the measurements 1.17MeV peak
18
A. Bross MICE CM17 February 2007 18 X-Ray Background Measurement of the 201-MHz cavity Data taken in Dec. 2006 and Jan. 2007 with superconducting solenoid off The counting rates have been measured as a function of rf gradients. In comparison with the x-ray intensity, the cosmic background is negligible. For MICE, accelerating gradient is 8MV/m limited by rf source MICE gradient
19
A. Bross MICE CM17 February 2007 19 Multipactoring Study ─ The impact of an electron to a surface can, depending on its energy and angle, release one or more secondary electrons into the vacuum. ─ These electrons can then be accelerated by the RF fields and impact with the same or another surface. Should the impact energies, number of electrons released and timing of the impacts be such that a sustained multiplication of the number of electrons occurs, the phenomenon can grow exponentially and may lead to operational problems of the RF system such as damage of RF components or loss/distortion of the RF signal. Multipactoring is an effect that occurs when the electrons accelerated by RF fields are resonantly enhanced via an electron avalanche caused by secondary electron emission
20
A. Bross MICE CM17 February 2007 20 Multipactoring? Possible multipactoring effects at some gradients, e.g., ~ 6.8MV/m in 201MHz cavity There may be a very weak multipactoring effect. But too weak to distort rf field and produce huge ripples like above. Multipactoring? Typical multipactoring waveform pattern observed at the 805 MHz cavity at MTA
21
A. Bross MICE CM17 February 2007 21 Energy Spectrum Measurement of the 201MHz cavity At 8-MV/m, the total counts recorded during 1000 rf pulses: u #8: ~ 30,000; #16: ~ 21,000
22
A. Bross MICE CM17 February 2007 22 X-Ray Background Measurement of the 805- MHz Cavity When the rf gradient is higher than ~ 13-MV/m, the counting rates increase significantly (over 1 million/s) the NaI detector is not able to keep up and saturated. The counting rate is not accurate anymore, nor is the energy spectrum. Cosmic background x-ray saturated
23
A. Bross MICE CM17 February 2007 23 201 MHz Cavity Status The 201 MHz Cavity is back up ready for operation We had a short in the 4” coax feeds to the couplers u The problem seemed to stem from the fact that parts from multiple vendors where used in the 4” coax run s Power coupler s Straight sections s Elbows u At the interfaces between parts from different vendors, the fit- up was not ideal s Inner conductor specifications seemed to vary This has now been fixed In addition we will be using pressurized (12 pisg) SF6 in the 4” coax run as the insulating gas instead of air
24
A. Bross MICE CM17 February 2007 24 201 Coax Post-Mortem
25
A. Bross MICE CM17 February 2007 25
26
A. Bross MICE CM17 February 2007 26 High Pressure H 2 Filled Cavity Work Muon’s Inc High Pressure Test Cell Study breakdown properties of materials in H 2 Run in B field No degradation in M.S.G. up to 3.5T