Click to edit Master title style Pilot renovation project in Estonia Targo Kalamees, Kalle Kuusk, TUT H2020 MORE-CONNECT 1st Meeting (Kick-off) 2015 January 12 and 13
2
General description Prefabricated concrete large panel element Typical soviet series apartment building: solutions and results are easily to disseminate Construction date1986 Number of stories5 Net area3824 m 2 Heated area3306 m 2 Living area2769 m 2 Number of apartments80
4
Current energy use (HDD Tallinn = 4220 ºC∙h) 200820092010Average Delivered energy, kWh/(m 2 ·a) Space heating 126116150131 Domestic hot water 107938595 Electricity 5446 48 Primary energy, kWh/(m 2 ·a) 318280303300 New building Low en. building nZEB Major renovation 100 101… 120 121… 150 151… 180 181… 220 221… 280 281… 340 341 Primary energy, kWh/(m 2 ·a)
5
Preliminary estimation about renovation solution Building envelope: Exterior wall:U 0,12 W/(m 2 K) Basement wall:U 0,17 W/(m 2 K) Roof:U 0,10 W/(m 2 K) Windows:U 0,80 W/(m 2 K) Basement ceiling:U 0,26 W/(m 2 K) Insulation of loggias interior heated area Ventilation: balanced ventilation with HR in each apartment Heating: radiators, thermostats, renovation of heat centre Solar collectors for DHV on roof PV for electricity on facades MORE-CONNECT engine: in loggia or on roof
6
Preliminary estimation of energy use Current useStandard use NowMoreCon.NowMoreCon. Net energy, kWh/(m 2 ·a) Space heating98199819 Ventilation291313651313 Domestic hot water95 30 Appliances48 29 Fans, pumps0606 Produced energy on site, kWh/(m 2 ·a) Solar collectors (heat)0-240 PV panels (electricity)0-50 Delivered energy, kWh/(m 2 ·a) Space heating1012011520 Ventilation30146814 Domestic hot water9571306 Appliances48432924 Fans, pumps0606 Primary energy, kWh/(m 2 ·a) Energy performance value 31319325096 = nZEB