Download presentation
Presentation is loading. Please wait.
Published byBrianna Cobb Modified over 9 years ago
1
Ionizer IZS31 Series
2
1. Features (1) Following functions are added to the current IZS30 on sale. Detects the dirt on the electrode needle. Detects the dirt on the electrode needle, and outputs the maintenance signal. 3-detection-level setting Auto balance function It automatically adjusts the ionic balance around work by using the auto balance sensor. Continuous electrostatic removal drive is added to the sensing DC mode. After completing the electrostatic removal, it discharges ion continuously by using the Pulse DC.
3
External synchronous signal input terminal is added. Input of the positive synchronous signal from outside generates positive ion. Input of the negative synchronous signal from outside generates negative ion. Use of an external transmitter enables synchronization of the ion generation timing of two or more ionizers. (Synchronization function) Use of PLC, etc. enables discharge of ion of an arbitrary polarity for arbitrary period of time. 1. Features (2)
4
Sensor is miniaturized. Detecting method is changed and sensor miniaturized. 3 kinds of sensors are available. 3 kinds of sensors are 1.Feedback sensor Detects the amount of electrification of work and discharges the ion of reverse polarity to improve the removal speed. 2. Auto balance sensor Adjust ion balance automatically. 3. Sensor which can be used by itself Outputs the detected amount of work electrification in the analog signal from 1 to 5V. The power supply is 24V DC. 1. Features (3)
5
2. Purpose of Development Purpose of development IZS30 has been released in December 2004. This time, because the detection of dirt on electrode needle which has been required by customers from the beginning became technically possible, IZS31 was developed as a remodel of the IZS30 in compliance with new requirements by customers. Target field and industry Semi-conductor, liquid crystal, film manufacturing, resin molding, those related to food
6
3. Application Prevents adhesion of dusts in production lines of rolled film, etc. Prevents absorption of molded parts in plastic molding line Prevents electrification destruction in a whole production line of semi- conductor Prevents adhesion of dust to liquid crystal and PVD during inspection and damage when handled
7
4. Specifications and Performance NPNPNP Air purge Current consumption When auto balance sensor is used while standing by Pulse DC mode Power supply voltage24V DC +/- 10% Sensing DC mode while removal of electrification 250mA or less Operating pressure 0.7MPa or less Tube bore size 44 Ion balance -30 to +30V ( Stainless electrode needle: -100 to +100V) FluidAir (clean dry air) Voltage applying method Sensing DC / Pulse DC / Positive DC / Negative DC Discharge outputApprox. +/-7000V Model No.IZS31 Signal Ion generation methodCorona discharge type Sensing DC mode 210mA or less 250mA or less
8
Cartridge Body End bracket Cartridge drop prevention cover is added. 5. Construction
9
Changed Points 1 with the Cartridge Insert Rotate Locking type of the 2 actions (1) Insert -> (2) Rotate to lock Lock Clicking is felt when locked.
10
Changed Points with the Body Construction to which the electrode cartridge 40mm can be installed Standard product has the same 80mm pitch as the current one, but 40mm pitch is available as special. 40mm
11
Changed Points with End Bracket IZS30 (Current) IZS31(Remodeled) Resin Fixed to the body with 2 bolts Pressed SUS Angle fixed with 2 bolts Angle fixed with 1 bolt 106 10 0 Fixed to the body with 4 bolts
12
Drop Prevention Cover Drop prevention cover Inserted to the groove on the cover be fixed
13
6. Comparison with Competitors ItemIZS31TT Electrode cartridge drop prevention cover Equipped Not equipped Frequency 1 to 600Hz1 to 33Hz Electrode cartridge mounting pitch Standard 80mm Special 40mm 60mm Improved in removal speed of electrification by feedback sensor Improved Not improved Automatic ion balance adjustment by auto balance sensor Possible Not possible Axial outlet of power cable Available as special Not available Intermediate length Available as special Not available
14
7. System and Part Number of Series IZS31-780 C P Z – B F Electrode needle material No symbol: Tungsten C : Silicon S: Stainless steel Bracket No symbol : Without bracket B: With bracket Bar length 300 to 2300 Output specification No symbol: NPN P: PNP Sensor F: Feedback sensor G: Auto balance sensor Power cable length No symbol: 3m Z: 10m
15
8. Outline Dimensions Body of the Ionizer 300 to 2300 30 58 Dimensions of IZS30 and IZS31 are common. Standard bar length 300,380,620,780,1100,1260,1500,1900,2300
16
8. Outline Dimensions Auto balance sensor Surface potential sensor (used by itself) Feedback sensor 6995 17 23 AmplifierHead Head (Dimensions of the amplifier is common for all series.) 95 20
17
9. Precautions Be sure to ground. Connect the FG terminal (green) of the power cable with the ground resistance of 100 ohms or less.