Optical Manufacturing Solutions 1 Setting Vacuum Sensor Level
2
Optical Manufacturing Solutions 2 Setting Vacuum Sensor Level Remove the (2) sections shown to make the proper adjustments.
3
Optical Manufacturing Solutions 3 Setting Vacuum Sensor Level First touch Setup on the Job screen. Next touch Diagnostics. Touch Automation. This screen will be used for all adjustments to the vacuum sensor levels:
4
Optical Manufacturing Solutions 4 Setting Vacuum Sensor Level The following are the sensors to adjust. The button on the rear is cup 2 (unload sensor), circled in red, and the one circled in blue is cup 1 (loading sensor).
5
Optical Manufacturing Solutions 5 Setting Vacuum Sensor Level Select Vacuum 1 ON and place a lens on the #1 suction cup Select Air ON for Suction Cup 2 Press the EDIT button on the Sensor #1 until the light is blinking and then let off the EDIT button “sometimes holding lens loosely to this cup may help set the sensor in worse possible condition” This will set Suction Cup 1 Select Vacuum 2 ON and place a lens on Suction cup 2 Select Air ON for Suction cup 1 Press the EDIT button on Sensor #2 until the light is blinking and then let off the EDIT button “sometimes holding lens loosely to this cup may help set the sensor in worse possible condition” This will set Suction Cup 2 (If still having trouble with the sensor this process may need to be repeated)