Download presentation
Presentation is loading. Please wait.
Published byBrittany Carroll Modified over 9 years ago
1
EPA’s 2001-Published Heavy-Duty Diesel PM Test Procedure Changes Matthew Spears EPA’s Office of Transportation & Air Quality
2
Introduction n EPA made significant changes to 40 CFR Part 86, Subpart N as part of the 2007 Heavy-Duty Diesel Engine Regulation n Worked closely with engine manufacturer’s experts in certification test procedures n Available at: http://www.epa.gov/otaq/regs/hd2007/frm/frdslreg.pdf http://www.epa.gov/otaq/regs/hd2007/frm/frdslreg.pdf
3
§86.1306-07; Overview n New test procedures may be implemented immediately –Certain procedures must be used with others n Application for approval of alternate procedures is now specified, including: –Theoretical explanation –Detailed description of any hardware and software –Detailed description of any calibration, operation and maintenance procedures –Statistical comparison of experimental results
4
§86.1310-07; Analytical Systems n Multiple sampling systems are allowed n Recommended low thermal capacity dilution tunnel n Recommended CVS mixing test n Dilution air filtration is specified –98% efficient filtration for primary, HEPA for secondary n Dilution air minimum temperature: 15C
5
§86.1310-07; Analytical Systems n Smaller PM probe allowed n Double dilution is required for PM sampling n Preclassifier required after double dilution –99% penetration at 1um, 50% cut at 2.5-10um n ~47mm diameter filter diameter required n High efficiency filter media required (e.g. TX-40, Teflo) n Single filter cartridge and cartridge holder design specified n Filter face temperature: 47 +-5 C
6
SUB-SONIC VENTURI (SSV) (OPTIONAL FOR CFV, SSV) PARTICULATE PRE-CLASSIFIER OPTIONALLY HEATED
7
§86.1312-07; Filter room n More stringent temperature and dew point specifications –22+-3C (+-1C at microbalance), 9.5+-1C dewpoint n More stringent reference filter weight change: 10ug n More stringent microbalance performance specifications n Require balance operator grounding to balance n Specified electrostatic neutralizer performance n Allowed repeat weighing and statistical analysis n Required buoyancy correction n Recommended vibration, electrostatic, and draft isolation of microbalance n Recommended Class 1000 clean room conditions
8
PM Filter Handling
9
§86.1334-07; Preconditioning n Added 20 minute steady-state high temperature preconditioning cycle
10
§86.1337-07; Test Run n No longer require engine detachment from CVS during hot soak
11
Additional Guidance Given in 2002 “Dear EMA” Letter n Worked closely with manufacturers and met on a monthly basis to understand mfr. needs n Clarified a sound sequence to implement PM measurement changes incrementally n Provided an improved statistical test for equivalent methods n Provided approvable practices on –PM measurement techniques –Forced aftertreatment cool-down –Subsonic Venturi calibration
12
EPA’s Assessment of Current Measurement Variability n Current variability does not limit laboratories at 2007 certification levels n EPA has demonstrated this with 2007-level data n Not via statistical or “thought” experiments –Data not based on product literature on instrument performance –Data not based on speculations on emissions dynamic range
13
NOx Measurement n Low NOx measurements agree well between bag and continuous analyzers n EPA believes that today’s continuous measurement technique is viable for certification at 2007-levels
14
Continuous versus Bag NOx Measurement Using Old Beckman 955 Comparison made on hot start HDD FTP. Dual path NOx adsorber system.
15
Continuous versus Bag Measurement Using New Horiba CLA-720MA Comparison made on hot start HDD FTP. Dual path NOx adsorber system.
16
PM Measurement n Microbalance weighing is largest source of variability n Current variability is only 25% of rounding allowance at the standard n Repeat reference filter weights at +-1.5ug is achievable –EPA results consistent with Ford and SwRI –Indicates that 30-60 ug filter loading is sufficient
17
PM Measurement Concern
18
PM Measurement
19
FTP PM Emissions For Engine Out and Post Traps
20
FTP CVS Filter Weight Gain For Engine Out and Post Traps
21
NMHC Measurement n NMHC –Have met standards using aftertreatment »assuming NMHC = 0.98*THC –Recent measurements indicate »NMHC = ~0.5*THC –Latest results are now less than ½ of the standard
22
NMHC Measurement
23
EPA’s Next Steps n Ensure lab-to-lab variability is well-controlled –Continue mfr. lab tours such as at EPA, SwRI, and CARB –Continue to meet with manufacturers to ensure correct implementation of new test procedures n Committed to pursuing improvements –Implementing highly recommended a-b-a PM weighing –Procuring state-of-the-art systems »New low NOx diesel analyzers »New 2007 PM measurement system »New heated bag system for HC »Low-loss dilution tunnel –Supporting measurement research: CRC E-66 –Preparing Part 1065 for future application for on-highway
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.