Presentation is loading. Please wait.

Presentation is loading. Please wait.

Make the most of your energy December 2008 HDM Accurate measurement and electrical utility cost allocation for multi-tenants PowerLogic ® High Density.

Similar presentations


Presentation on theme: "Make the most of your energy December 2008 HDM Accurate measurement and electrical utility cost allocation for multi-tenants PowerLogic ® High Density."— Presentation transcript:

1 Make the most of your energy December 2008 HDM Accurate measurement and electrical utility cost allocation for multi-tenants PowerLogic ® High Density Metering Enclosures

2 Schneider Electric 2 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering overview ●PowerLogic® High Density Metering (HDM) products are pre-wired, multi or single meter cabinets that offer a high quality, cost effective solution for submetering/billing, monitoring energy usage or energy cost allocation. ●They are ideal for new and retrofit construction in commercial, residential and industrial facilities and are easy to specify, purchase and install. ●PowerLogic HDM cabinets are available in multiple configurations and can be equipped with a choice of ANSI certified and reliable PowerLogic meters.

3 Schneider Electric 3 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering overview – cont. ●PowerLogic HDM cabinets are available in 1-meter, 4-meter, 8-meter and 16-meter configurations. ●Type 1 (indoor) – available with 1, 4, 8, & 16 meters ●Type 3R (outdoor) available with 1 & 4-meter enclosures ●A variety of PowerLogic meters are available: 1 & 4-meter 8 & 16-meter ●Optional Modbus TCP/IP when ordered with integrated EGX (8 and 16- meter enclosures). ●Designed for use with a variety of PowerLogic software, including: Tenant Metering software, Tenant Metering Commercial Edition software, SMS or ION Enterprise®.

4 Schneider Electric 4 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering applications ●Tenant Sub-metering – Accurately bill tenants for their energy usage. ●Benefit – Data can be used to offer reduced lease rates ●Energy cost allocation – Allocate facility energy costs based on actual usage by department, tenant and cost center. ●Benefit – Identify energy conservation measures that won’t heavily impact people or processes ●Demand Control – Discover your facility’s electricity usage patterns, total period energy consumption and peak demand. ●Benefit – Use the data to establish a baseline and reduce demand charges and lower long-term energy costs

5 Schneider Electric 5 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering customers ●PowerLogic HDM cabinets are ideal for organizations such as government, educational, transportation, property management and entertainment or leisure venues that want to improve energy efficiency and allocate costs or bill tenants within their facilities: Suitable building types include, but are not limited to: ●Office buildings ●Malls and retail operations ●Universities and colleges ●Government facilities ●Multi-use commercial and residential ●Hotels and entertainment venues ●Airports and other transportation facilities

6 Schneider Electric 6 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering benefits ●Outstanding quality, equipped with full-featured meters with easy to read displays and intuative interfaces ●Cabinets are pre-wired, for easy mounting and installation in new and retrofit applications ●Installation keyholes simplify mounting for 1 and 4 meter enclosures while mounting channels and surface mount flanges enable easy installation for 8 and 16-meter HDM ●Space saving design offers a small footprint for mounting next to an existing panelboard ●Add additional meters to empty slots as your needs change ●Industry standard Modbus communication and available Ethernet

7 Schneider Electric 7 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering general features ●All configurations ●Extensive voltage input options: ●120/240 volt single phase ●120/208 and 240 volt three phase ●480 volt three phase ●600 volt three phase (4-meter) ●Rugged, lockable steel cabinets provide tamper-resistant security ●Factory-installed shorting block(s) ●Standard RS485 Modbus® communications or available Ethernet Modbus® TCP/IP (not available on 1-meter HDM ●Utilizes 5A CTs (not included with enclosure). Shorting Blocks EGX mounting space Factory installed wiring harnesses UL489 CB

8 Schneider Electric 8 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering 1-meter HDM features ●Versatile 1-meter HDM is available in Type 1 (indoor) or Type 3R (outdoor) ●Can be equipped with high quality PowerLogic PM210, PM750 or ION6200 meters. ●Comes with the meter you choose pre-installed and wired ●Energy and power accuracy ●PM210 = ANSI C12.16. 1.0 Accuracy Class ●PM750 = ANSI C12.16. 0.5 Accuracy Class ●ION6200 = ANSI C12.16. 0.5 Accuracy Class

9 Schneider Electric 9 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering 1-meter HDM dimensions

10 Schneider Electric 10 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering 4-meter HDM features ●4-meter HDM is available in Type 1 (indoor) or Type 3R (outdoor), requires minimal wall space ●Comes with the meter you choose pre-installed and wired for field termination ●Voltage disconnect for phase voltages & auxiliary control power ●Energy and power accuracy ●PM210 = ANSI C12.16. 1.0 Accuracy Class ●PM750 = ANSI C12.16. 0.5 Accuracy Class ●ION6200 = ANSI C12.16. 0.5 Accuracy Class ●Utilizes 5A CTs ●Standard RS485 Modbus®

11 Schneider Electric 11 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering 4-meter HDM dimensions

12 Schneider Electric 12 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering 8 and 16-HDM features ●Standard power meters mounted in a Type 1 enclosure ●Factory-installed wiring harness for each row of meters ●The panel is prewired to terminal block for easy field connections ●Integral power circuit protection (UL489) on 8 and 16-meter enclosures ●Energy and power accuracy ●PM210 = ANSI C12.16. 1.0 Accuracy Class ●PM750 = ANSI C12.16. 0.5 Accuracy Class ●Utilizes 5A CTs ●Standard RS485 Modbus® or optional Modbus TCP/IP

13 Schneider Electric 13 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering 8 and 16-meter HDM dimensions 8-meter cabinet 16-meter cabinet

14 Schneider Electric 14 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering Cabinets meter selections ●Meter selections for all cabinets: ●PowerLogic® PM210 Entry-level meter, ideal for single phase or three-phase applications ●PowerLogic® PM750 Full-featured, high accuracy device with I/O, THD, min/max & more ●Additional meter option for 1 and 4-meter cabinets ●PowerLogic® ION6200 Exclusively for 600 volt for applications, it offers an LED display, and extended operating temperature range for outdoor applications PM210 PM750 ION6200

15 Schneider Electric 15 - Marketing – HDM – December 2008 PowerLogic® High Density Metering Cabinets meter comparison chart FeaturesPM210PM750ION6200 Energy and power accuracyANSI C12.16. 1.0ANSI C12.20. 0.5 Instantaneous RMS values Current, Voltage, Frequency Power Real, Reactive, Apparent, PF total Energy values Active, reactive, apparent energy Demand Current, power (active, reactive, apparent) Power quality measurements Harmonic distortion (current, voltage)– Data recording Min/max of instantaneous values– – Display and I/O Backlit LCD display LED Display Pulse output–12 Pulse input–2– Communication RS485 port with Modbus protocol Alarms –

16 Schneider Electric 16 - Marketing – HDM – December 2008 Software for a Total Solution: PowerLogic ® billing software ●Two cost effective, easy-to-use software options to choose from ●Common benefits include: ●Automatically collect meter data ●Support electricity, gas and water meters ●Generate customized tenant billing and account statements

17 Schneider Electric 17 - Marketing – HDM – December 2008 Software for a Total Solution: PowerLogic ® billing software ●Two cost effective, easy-to-use software options to choose from ●Common benefits include: ●Automatically collect meter data ●Support electricity, gas and water meters ●Generate customized tenant billing and account statements ●PowerLogic Tenant Metering – Commercial Edition ●Billing based on interval data ●Real & reactive energy ●Flat & tiered rates ●Demand & power factor ●Seasonal rates ●Time of Use ●Miscellaneous charges ●PowerLogic Tenant Metering ●Real energy ●Flat & tiered rate ●Billing based on total consumption (kWh)

18 Schneider Electric 18 - Marketing – HDM – December 2008 Software for a Total Solution PowerLogic ® Tenant Metering software ●Low-cost, easy-to-use ●Automatically collects meter data ●Support electricity meters (real energy) ●Generate customized tenant billing and account statements or use the Export Tool for data integration with third party billing services

19 Schneider Electric 19 - Marketing – HDM – December 2008 PowerLogic® Tenant Metering Commercial Edition ●TMSCE is built on a utility-grade billing engine and offers more functionality and flexibility for demanding billing applications ●Invoicing based on consumption, TOU (Time Of Use), seasons, demand, & PF ●WAGES support ●Ability to allocate meters across tenants ●Ability to assign multiple meters to a single tenant ●Virtual meter support ●Customizable billing cycles ●Load profile reporting