Download presentation
Presentation is loading. Please wait.
Published byGerard Walters Modified over 8 years ago
1
ICONICS 2008 Worldwide Customer Summit Boston, MA Michael Hiefner, Dallas, TX Jim Desrosiers, Hampton, NH Phil Koehler, Philadelphia, PA Alexander Klimov, Foxboro, MA James Phelps, Foxboro, MA
2
Agenda AlarmWorX64 Design Goals A Dozen Reasons Why OPC UA Alarm & Events OPC UA Alarm Concepts Products in this Session AlarmWorX64 Configurator Runtime Viewer Analytics, Reporting… Demonstration Wrap-up Questions Quiz 2
3
Distributed Enterprise-Wide Alarm Management Flexible Configuration Web-Configurable Integrated Workbench Optimistic Concurrency Scalable Object-Oriented Groups & Areas Analytics & Reporting ICONICS 2008 Worldwide Customer Summit – Boston, MA 3
4
Universal Connectivity OPC-Unified Architecture OPC-DA, Databases, SNMP, BacNET, Business Systems… High-Availability Highly Reliable Mission-Critical Applications 64-Bit Power Certified for Windows Server 2008 Certified for Windows Vista XP64, 2003 Server ICONICS 2008 Worldwide Customer Summit – Boston, MA 4
5
Combine Historical and Real-Time Alarms Group and Browse Using Tab Organization Configure Groups of Alarms by Area, Severity and more Configure Operator Views in Runtime Organize with Dynamic Mesh Browser ICONS for Status Indication: Flags, Arrows, etc. Runtime Data Analysis and Charting Real-Time Interactive Preview within Configuration Enhanced.Net Scripting - Full Programmatic Configuration Support Multi-Level Sorting & Filtering: By Time Range, etc… Customizable Reporting via Excel, PDF, CSV… Workbench Enables Simultaneous Configuration and Runtime ICONICS 2008 Worldwide Customer Summit – Boston, MA 5
6
6 DCOMNO DCOM
7
7 Alarms and Conditions Extend Base UA Eventing Model Conditions Are Not Just Transient Conditions Always Exist in Some Current State Conditions May Also Exist in the Address Space Alarm and Condition Model Uses UA State Machine UA Defines Standard State Machines For Alarm and Conditions Standard-State Machines Are Extensible
8
8 Condition state machine Defines base enable/disable state Condition subtypes defined Extended by the specification Can be extended by vendors Each state transition results in a Condition Event. Disabled Enable
9
9 Extends Enable State of Condition Type Defines two Acknowledge State Machines Basic Acknowledge model Acknowledge with Confirmation model Extendable by Vendors Disabled Enabled Unconfirmed Acknowledged Confirmed UnAcknowledged
10
The Power of 64-Bit Alarm Management Jim Desrosiers, Hampton, NH ICONICS 2008 Worldwide Customer Summit – Boston, MA 10
11
11 Devices Client Components Unified Data Browser GraphWorX64 TrendWorX64 Viewer TrendWorX64 Viewer Client Server AlarmWorX64 Viewer Configuration Components Client Server Configuration Databases Unified Data Manager TrendWorX64 Server & Logger TrendWorX64 Server & Logger AlarmWorX64 Server & Logger Hyper Historian Hyper Historian Aliasing Security Configuration Services (SOA) Workbench ICONICS Runtime Framework Application Servers OPC UA Servers (Complex Data, DA, HDA, AE) OPC Servers (DA, HDA, AE) Event Logging Event Logging Licensing Unified Data Manager TrendWorX64 Server & Logger TrendWorX64 Server & Logger AlarmWorX64 Server & Logger Hyper Historian Hyper Historian Aliasing Security SNMP Logger Databases
12
DEMONSTRATION Configuration Runtime Viewer Analytics, Reporting… ICONICS 2008 Worldwide Customer Summit – Boston, MA 12
13
Combine Historical and Real-Time Alarms Group and Browse Using Tab Organization Configure Groups of Alarms by Area, Severity and more Configure Operator Views in Runtime Organize with Dynamic Mesh Browser ICONS for Status Indication: Flags, Arrows, etc. Runtime Data Analysis and Charting Real-Time Interactive Preview within Configuration Enhanced.Net Scripting - Full Programmatic Configuration Support Multi-Level Sorting & Filtering: By Time Range, etc… Customizable Reporting via Excel, PDF, CSV… Workbench Enables Simultaneous Configuration and Runtime ICONICS 2008 Worldwide Customer Summit – Boston, MA 13
14
ICONICS 2008 Worldwide Customer Summit – Boston, MA 14
15
ICONICS 2008 Worldwide Customer Summit – Boston, MA 15
16
ICONICS 2008 Worldwide Customer Summit – Boston, MA 16 Interactive Preview While in Configuration Interactive Preview While in Configuration
17
ICONICS 2008 Worldwide Customer Summit – Boston, MA 17
18
ICONICS 2008 Worldwide Customer Summit – Boston, MA 18
19
ICONICS 2008 Worldwide Customer Summit – Boston, MA 19
20
ICONICS 2008 Worldwide Customer Summit – Boston, MA 20
21
ICONICS 2008 Worldwide Customer Summit – Boston, MA 21
22
Full Programmatic Configuration Support Tremendous power for the OEM User ICONICS 2008 Worldwide Customer Summit – Boston, MA 22
23
ICONICS 2008 Worldwide Customer Summit – Boston, MA 23
24
ICONICS 2008 Worldwide Customer Summit – Boston, MA 24
25
Power to Turn Information into Intelligence ICONICS 2008 Worldwide Customer Summit – Boston, MA 25
26
Combine Historical and Real-Time Alarms Group and Browse Using Tab Organization Configure Groups of Alarms by Area, Severity and more Configure Operator Views in Runtime Organize with Dynamic Mesh Browser ICONS for Status Indication: Flags, Arrows, etc. Runtime Data Analysis and Charting Real-Time Interactive Preview within Configuration Enhanced.Net Scripting - Full Programmatic Configuration Support Multi-Level Sorting & Filtering: By Time Range, etc… Customizable Reporting via Excel, PDF, CSV… Workbench Enables Simultaneous Configuration and Runtime ICONICS 2008 Worldwide Customer Summit – Boston, MA 26
27
ICONICS 2008 Worldwide Customer Summit Boston, MA QUESTIONS???QUIZ!
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.