Download presentation
Published byRaymond Edwards Modified over 9 years ago
1
North Hills Junior High School Schematic Lighting Design
Chris Rush The Pennsylvania State University Architectural Engineering – Lighting / Electrical Consultant: Dr. R. Mistrick Fall 2004
2
Building Introduction
Uses: Education Evening Events Performances Athletics
3
Spaces Main entrance canopy Main entrance lobby Auditorium
Typical classroom
4
Main Entrance Canopy Architectural Elements
Translucent panel canopy on steel trusses Brick and concrete columns Glass entry doors Three flag poles Semi-circular concrete patio Wrought iron style benches
5
Main Entrance Canopy Concepts Criteria Inviting Prominent Industrial
Pleasing appearance Enhance architecture Illuminate flags 5 fc under canopy
6
Main Entrance Canopy Direct / indirect pendants hung from trusses
Exterior sconces mounted on columns with up & down distribution Surface mounted downlights under solid roof
7
Main Entrance Canopy
8
Main Entrance Lobby Architectural Elements
Trophy cases in wood panel wall Auditorium entrance doors Main office door and windows Display cases and boards
9
Main Entrance Lobby Criteria Concepts Pleasing appearance
Avoid veiling reflections in display case glass Focus on display cases and auditorium entrance 10-20 fc average Concepts Welcoming Spirited Social
10
Main Entrance Lobby Red NH logo ceiling installation
Fluorescent strip cove encircling logo
11
Main Entrance Lobby
12
Auditorium Architectural Elements Dark wood proscenium Red seating
Sloped floor and ceiling (25’ height) Curved ceiling at stage Low ceiling at rear
13
Auditorium Concepts Criteria Spacious Relaxed
Guide attention toward stage Fully dimmable Non-distracting 30 fc average
14
Auditorium Continuous rows of narrow fluorescent fixtures in line with aisles Upward cove mounted along side walls
15
Auditorium
16
Classroom Architectural Elements Chalk boards Tack boards
Projection screen Two north facing 6’x6’ windows Countertop with overhead cabinets and computer connections
17
Classroom Concepts Criteria Clear Stimulating Workplane illuminance
Chalkboard illuminance Daylight consideration Visual comfort 50 fc average 3:1 max:min ratio Ceiling and luminaire luminances low enough for occasional VDT use
18
Classroom Direct/indirect fluorescent pendants
Linear fluorescent chalkboard lights
19
Classroom
20
Summary Entrance Canopy Entrance Lobby Auditorium Classroom
Pendants hung from trusses Wall sconces mounted on columns Surface mounted fixtures under solid roof Entrance Lobby NH logo ceiling installation Fluorescent coves around logo Auditorium Continuous row narrow fluorescent over aisles Upward cove lighting along side walls Classroom Direct/indirect fluorescent pendants Linear fluorescent chalkboard lights
21
Questions ??