Schematic Lighting Design Natty Boh Building Baltimore, Maryland Eric Singley Penn State University Architectural Engineering
2
Location Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Brewers Hill Baltimore, Maryland
3
Project Information Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Building Statistics: Overall Building Size : 189,550 ft 2. Maximum Height : 9 stories Multi-purpose: office, storage, residential, commercial Building Character: Old home of the Gunther Brewing Company. Consists of 6 sections of differing heights. Declared a historic place in 2002.
4
Design Spaces Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Large Work Space Friday’s Day Care Center Circulation Space Canton Self Storage Lobby Outdoor Space Parking lot and rear facade Special Purpose Space Countrywide conference room
5
Day Care Center Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Space Properties Floor area 4092 ft 2. Exposed ceiling at 14 ft. Large windows on east and west walls. Interior partitions dividing kitchen and storage areas. Space Tasks Primarily play and learning area for small children. Light kitchen use.
6
Day Care Center Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal
7
Day Care Center Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Design Goals Separate the spaces by function with lighting. Create a more ‘playful’ atmosphere within the child care area. Make use of the large windows to introduce daylighting to the space. Flynn mode – Relaxed. Power Density 1.5 Watts per square foot allowed.
8
Day Care Center Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Design Solution Drop ceiling to 9’. Recessed linear fluorescent downlights in walkways. Recessed CFL downlights in childrens’ area and kitchen. Under-cabinet lights in kitchen. LED color spots on columns.
9
Day Care Center Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Daylight Integration Kitchen lights and window- side children’s are lights on their own circuit. Use Photometric sensor with manual override for control.
10
Lobby Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Space Properties Floor Area ≈ 2500 ft 2 Ceiling at 8 ft and 21.5 ft No windows Entrances on both levels Space Tasks Light office work Display of model storage unit Sales / Receptionist desks
11
Lobby Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal
12
Lobby Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Design Goals Accentuate the double height ceiling. Direct customers from entrances to the sales desk. Provide a non-complex design solution. Flynn mode – Spacious. Power Density 1.3 Watts per square foot allowed.
13
Lobby Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal
14
Lobby Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Design Solution CFL downlights over desks. Recessed CFL downlights in 9’6” portion lower ceiling. Linear fluorescent wallwash along open wall. Wallwashers on 21 ft walls to accent their height.
15
Conference Room Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Space Properties Floor Area : 150 ft 2 Ceiling at 8 ft Conference table with chairs No windows Space Tasks Professional and Casual conferences Possible light video conferencing
16
Conference Room Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal
17
Conference Room Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Design Goals Create a comfortable yet professional environment. Provide flexibility to accommodate different uses. Including: Presentations Video conferencing Roundtable discussion Flynn mode – Spacious/Focused Power Density 1.5 Watts per square foot allowed
18
Conference Room Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Roundtable Discussion Recessed CFL downlights on the conference table. Linear Fluorescents washing walls and ceiling to provide ambient lighting.
19
Conference Room Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Presentation Ambient lighting remains on. Reduce the number of downlights on the conference table. Two spot lamps on podium.
20
Conference Room Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Video Conferencing Dimmed ambient lighting. Spot lamps on individual faces. Downlights on table reduced further.
21
Exterior Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Space Properties Ground Area : 37,050 ft 2 Surrounded on 3 sides by buildings Historically significant Space Tasks Parking for Natty Boh Building Entrance to the building
22
Exterior Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal
23
Exterior Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Design Goals Provide sufficient light to allow drivers to read signs and see parking lines. Call attention to the building entrances. Achieve 100% Dark Sky compliance. Maintain similar luminaire appearance. Power Density 0.3 Watts per square foot allowed
24
Exterior Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Design Solution Spotlight building entrances. Prevent spill into windows. Keep light poles on existing islands.