目录 12 in 1 Sensor Features ● PIR motion sensor ● Ultrasonic sensor ● LUX sensor ● Temperature sensor ● 2 Dry contacts ● 2 external condition inputs ● IR(infrared) receiver ● IR(infrared) transmitter ● 2ch 5A Relay outputs ● Constant LUX control ● security alarm logic (works with Security Module) ● 24 configurable logics
2
Subnet ID and Device ID Device remark LED On/Off Option
3
1.Input a range to be involved. 2.Select code and upload it to 12in1, it shall be shown in the left table. 3. Test the code in 12in1.
4
These 8 keys match with the 8 keys of HDL remote SB-HHR-D (default mode). Enable/Disable IR Code Receiver
5
Select key control mode Sav e
6
Set targets for each key.
7
Test the IR receiver of 12in1 NOTE: make sure the remote is in default mode (please refer to doc for SB-HHR-D.)
8
Right click to refresh the status displaying. Adjust Sensors Constant LUX function (pay attention to the remarks)
9
Power OFF Recovery options: No Action (default) True False Power-off status Right click to refresh the status displaying. Delay to execute the logics (in case the HDL-BUS has been loaded up when just powered on)
10
Combine logic input conditions Select logic relation
11
Logic True Delay Time before Sending Targets Set targets in “Logic True Target Setting” page Logic False Delay Time before Sending Targets Set targets in “Logic False Target Setting” page
12
Enable the security function of ch1 Assign ch1 to the security module(1/8) and security area (1).
13
Built-in 2 Channel 5A Relay Cycle Mode: relay turns on and off periodically. Pay attention to the tips here
14
Simulate some sensor value or status. This is very useful when to test the new-created function.
15
Application requirements: 1. When people open the door and come into the meeting room, turn on the lights automatically 2. 1 minute after people come into the room, turn on the AC and set the temperature as 25 ℃ 3. 1 minute after people left the room, turn off the lights and set temperature as 27 ℃ 4. 3 minutes after people left the room, turn off the AC automatically
16
1. When people open the door and come into the meeting room, turn on the lights automatically Requirements
17
Save Suppose dry contact 1 has been connected with a magnetic contact and used to detect the door status. Select “movement” Select “And” delay time=0s.
18
Turn on the light when logic is true. Sav e
19
2. 1 minute after people come into the room, turn on the AC and set the temperature as 25 ℃ Requirements
20
Sav e Select “movement” Select “And” delay time=1m Select “connect” - door closed
21
Fill in the index no. here Sav e Check the index no. in SB-IR-EM, the third one is 25 ℃
22
3. 1 minute after people left the room, turn off the lights and set temperature as 27 ℃ Requirements
23
Sav e Select “No Movement” Delay time=1m
24
Sav e Turn off the light and set the temperature as 27 ℃
25
4. 3 minutes after people left the room, turn off the AC automatically Requirements
26
Save Select “No Movement” Delay time=3m
27
fill in the index no., Index no.=2 Sav e