Download presentation
Presentation is loading. Please wait.
Published byPauline Alexander Modified over 9 years ago
1
Diamond Radiator Fabrication and Assessment Brendan Pratt Fridah Mokaya Richard Jones University of Connecticut GlueX Collaboration Meeting, Jefferson Lab, February 2013
2
222 Uniform samples produced by VPIE raw material: type-3 CVD diamond from E6 original thickness ~150 microns 3 thinned samples: 150, 90, 30 microns thick 1.surface and thickness profiles with Zygo 2.X-ray rocking-curve topographs
3
3 X-ray diffraction assessment – June 2012 measurements at Cornell High Energy Synchrotron (CHESS)diffraction end-station C special monochromator setup and diffractometer configured for these measurements thanks to CHESS Staff Scientist Ken Finkelstein S150 S150 – thick reference standard S90 S90 – intermediate reference S30 – primary sample of interest
4
444 Diamond Laser Ablation at UConn UConn group has a pulsed excimer laser (193nm) that has been configured with optics for diamond machining. Laser operates at above ablation energies for hours of run time. Milling process has been automated for cutting predefined patterns in diamond (~30k pulses per fill) Beam spot has been “cleaned” of spherical aberrations. Milled trenches in Element6 3.2x3.2mm diamond Developed in-house ozone cleaning apparatus for removing amorphous carbon off milled diamond Vastly increase milling rate milling ~100microns/hr
5
55 sample 3: 30 microns thickness surface and thickness profiles (Zygo 3D)
6
66 S30: X-ray Measurements S30scan01 S30scan04
7
77 sample 2: 90 microns thickness surface and thickness profiles (Zygo 3D)
8
88 S90: X-ray Measurements
9
99 sample 1: 150 microns thickness surface and thickness profiles (Zygo 3D)
10
10 S150: X-ray Measurements
11
S150: Zygo Cross Section (before the accident) 11
12
12 Bob: X-ray Measurements
13
Bob: Zygo Cross Sections 13
14
14 First “picture frame” sample: U40 3 mm 300 micron frame around outside edge thinned inner rectangular window residual raster pattern is from a coarse laser step size
15
15 3D Zygo Images of U40 approximate bottom surface depth, Zygo measurement on next slide White-light interferometer gives surface and thickness profiles with sub-micron prec. top surface measurements with Zygo
16
16 U40: Original X-ray Measurements excellent result for thinned diamond! surface of U40 was not treated after ablation
17
17 U40: X-ray Measurements
18
18 Casey: X-ray Measurements
19
Casey: Zygo Cross Section 19
20
20 Most Importantly… Definition of the central region is good. Sharpness of the walls does not degrade with depth. Pileup of amorphous carbon is not catastrophic So far no clouding of the ablation chamber window from residue We’ve increased Ablation Rate to We’ve increased Ablation Rate to ~100microns/hr! ~100microns/hr!
21
21 Questions?
22
22 New vs. Old Spot Profile Approx. 0.3mm Approx. 0.2mm Approx. 0.60mm Approx. 0.15mm Wider spot size in y allows for larger step sizes and faster rasterizing. Aspect Ratio 1.5 Aspect Ratio 4 before after