Ray Casper - Foundations Engineer John Scanlon - Structural Engineer Jimmy Mounnarat - Fluid System Engineer Igor Babushkin - Solar Thermal Engineer Preliminary Design Review Austin Texas
2
PDR Agenda Introduction Floor plan layout House elevation drawings Foundation analysis Roof Truss analysis Hydronic subsystem analysis Heat Transfer analysis Building and Flat Plate Collector F-Chart analysis
3
Floor Plan Layout
4
House Elevation Drawings
5
Foundation Options Poured ConcreteCement Block Low labor cost Quicker Requires more material Prevents water intrusion Better heat retention Low material cost High Labor Cost Joints allow for water intrusion Weaker
6
Foundation Calculations 8’ Soil Depth 50’ x 30’ foundation 15 degree slope M Max on 50’ North wall Soil Density 100lb/ft 3 House load = 200lb/ft 2 8 inch thick poured FOS COMPRESSION = 87.2 FOS BENDING = 2.2
7
Roof Truss Analysis A “Double Howe” truss using 2X8 beams proved to be suitable for our application. Roof pitch is variable depending upon FPC placement.
8
Hydronic Subsystem Analysis Schematic Head Loss, Pump size, Performance Curves Copper vs CPVC Cost Comparison
9
Hydronic Schematic http://www.backwoodshome.com/articles/hackleman65.html
10
Head Loss Max Head Loss per system 51.4 ft. Assuming 3 FPC’s. Pump Size 2 pump options in series. Taco pump – 2 x $219.75 Grundfos pump – 2 x $269.75
11
Taco Cast Iron Model 009-F5
12
Grundfos UP26-96F
13
Cost Analysis Copper vs CPVC ~ 33% Copper – corrodes, promotes corrosion, expensive. CPVC – higher reistance to heated water, no soldering, no corrosion, cheaper. Pumps ~ 19%
14
Heat Transfer Analysis
15
Solar Thermal Compare Two FPC’s Determine Number of Panels Determine Angle
16
Alternative Energy– AE-26 Roof angle is Best at around 31 degrees Best area is around 54 ft 2
17
Economics of the AE-26 Chose 6 Panels because of the Thermal Output Data Panel : $825.00 Price per ft 2 : $34.88 Area: 25.35 ft 2
18
Sun Earth, Inc -- EP-21 Very strange slop calculation, 28 degrees is best slope Collector Panel area seems to be the best at 41.11 ft 2
19
Economics of the EP-21 Similarly to the previous choice, 6 panels are chosen Panel: 609.97 Price per ft 2 : $34.88 Area: 21.35 ft 2
20
Questions?