Download presentation
Presentation is loading. Please wait.
Published byDrusilla Henderson Modified over 8 years ago
1
Status of vertex efficiency evaluation Fabio Ambrosino, Patrizia de Simone, Paolo Massarotti, Vincenzo Patera the idea is to look for events where the neutral clusters candidates to come from a are in time with a “K charged” vertex so the selection of the sample is done using only EmC info K charged meeting - 2 february 2004 – P. de Simone
2
sample preselection K charged meeting - 2 february 2004 – P. de Simone triggering tag on one side a “good kaon” track is selected on the sample side, with standard cuts on momentum and I.P. distance the kaon track of the 2 body decay that tags the K + K - event is used as “handle” to clean the sample of the “good kaon” tracks, using the minimun distance r see the kaon track efficiency !! good K track Handle: K track with tagged decay K extrapolated rr 3 or more clusters are required on the sample side with Eclu > 50 MeV T + 6ns < Tclu < T + 55 ns
3
sample selection 00 E ,t ,x ±± E ,x ,t K tag tt pKpK pKpK t0t0 lKlK xKxK E ,t ,x starting from the first hit of the “good kaon track” we step along the path imposing that the “ “ neutral clusters are in time with the “kaon vertex position” (T 1 + T 2 )/2 = T + ToF(K) about 11% of the tagged events are selected, with a negligible contamination 0.1% (MC evaluated) K charged meeting - 2 february 2004 – P. de Simone vertex resolution tested on double tagged events vx vy 5.5 cm vz 2.5 cm r 7 cm … global vertex efficiency evaluation
4
kinematical fit K charged meeting - 2 february 2004 – P. de Simone the “neutral” K vertecies have been selected with a poor resolution but (E, t, x) of clusters, (p first_hit, x first_hit ) of the “good kaon track”, and his decay length are good starting point for a kinematical fit … imposing the kinematics of the 2 body decay K the goals are measure the K decay vertex measure the momentum measure the K momentum to distinguish the 3 body decay We are close to obtain l K 1 cm … work in progress !!!
5
nota bene … !!! K charged meeting - 2 february 2004 – P. de Simone once that we have selected the “neutral” K vertex we look for the charged K vertex reconstructed by the DC … we look for a vertex with a total charge +2 or –2 … theta p son (MeV) correct charge assignment wrong charge assignment about 15% of the recon vtx has a wrong charge assignment …
6
vertex efficiency vs K decay lenght K charged meeting - 2 february 2004 – P. de Simone cm MC data
7
vertex efficiency vs K decay lenght K charged meeting - 2 february 2004 – P. de Simone cm MC data Vtx global 73.0% Vtx global 70.4%
8
… just for fun … !!! K charged meeting - 2 february 2004 – P. de Simone ns K ToF distribution in the kaon reference system = 1/Slope 12.3 ns
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.