1
BESIII Cell-type EMC Photon Position Measurement Zhe Wang Mar. 2004
2
Contents: Introduction to Belle’s method Introduction to BaBar’s methods Other methods … A MC prototype ‘Matrix’ Analysis and understanding Conclusion
3
Introduction to Belle’s method Corrected center of gravity Formula Position correction By a detailed calibrated complicated function. By a detailed calibrated complicated function. And few dependence on θ and energy is found. And few dependence on θ and energy is found. For correction only a few dependence on energy and theta is found.
4
Introduction to BaBar’s methods Center of gravity Logarithmic weight method usually a≈4 usually a≈4 Some points will be dropped. Some points will be dropped. A mixing of these two methods Now we can only check its result from its original tests.
5
Others (E852) A weighted mean: Comparison done by E852 Optimization is done. But correction maybe not. Optimization is done. But correction maybe not.
6
Others (BaBar’s method comes from here.) NIM A311 (1992) 130
7
Others (GAMS) one-dimension Shower profile Methods: 1. corrected center of gravity 1. corrected center of gravity 2. 2. The ith cell = center cell The ith cell = center cell 3. 3.
8
Others (GAMS) two-dimension Shower profile Method
9
Others (GAMS-200) Direct Access Method: Four crystals are concerned: Four crystals are concerned: the Max. the Max. biggest horizontal neighbor biggest horizontal neighbor biggest vertical neighbor biggest vertical neighbor the fourth to form a box the fourth to form a box
10
A MC prototype ‘Matrix’
11
A 7×7 CsI crystal matrix in air Each cell: 5cm ×5cm ×28cm Gun: 100Mev—1.2GeV photon at (x,y,-1)m (x,y [0,2.5] flat distribution) at (x,y,-1)m (x,y [0,2.5] flat distribution) along direction of z axis along direction of z axis
12
Analysis and understanding Shower lateral profile: and Shower lateral profile: MACRO and micro Ratios of two counters: i: coordinate index for column or row 1. Clear target (relationship between signal ratios and position) 2. And easy realization. Density function: 1. Care more details. (cell structure, wrapping) 2. Analogous to heat dispersion in a plane. 3. Integration and fit need more CPU time.
13
Analysis and understanding Three kinds of methods: Weighted mean Guess a usable weight Fit Fitting based on 2- dimension distribution Experiment calibrated formula Directly find the relationship between the ratio of two signals and x from experiment
14
Analysis and understanding (MC)
17
Linear weight and logarithmic weight
18
Conclusion After some rough comparison and study, three easy methods will be realized first. They are: They are: Linear weighted mean Logarithmic weighted mean Experiment calibrated function