Download presentation
Presentation is loading. Please wait.
Published byAdele Williamson Modified over 9 years ago
1
Zhen YAN, Muon Offline DQ meeting, 05/10/2015 Signed off runs(express stream) since last Friday meeting Default defects: MS_RPC_BA_ROD_PROBLEM_1 MS_RPC_BC_ROD_PROBLEM_1 Additional defects/comments Run 280853 MS_CSC_EA_DISCONNECTED_2 Run 280950 TGC C11 HV glitch Muon Offline DQ shifter report Run 280950 Project Tag: data15_13TeV Run Start: 2015-10-03 19:35 CEST Run End: 2015-10-04 12:19 CEST # lumi blocks: 1062 Events: 49371897 Stable beams: Yes Online ATLAS Ready luminosity: 142.164 pb-1 Run 280853 Project Tag: data15_13TeV Run Start: 2015-10-02 09:12 CEST Run End: 2015-10-02 13:14 CEST # lumi blocks: 258 Events: 2861280 Stable beams: Yes Online ATLAS Ready luminosity: 10.657 pb-1 Run 280862 Project Tag: data15_13TeV Run Start: 2015-10-02 14:56 CEST Run End: 2015-10-03 07:37 CEST # lumi blocks: 1062 Events: 50738248 Stable beams: Yes Online ATLAS Ready luminosity: 147.144 pb-1
2
Zhen YAN, Muon Offline DQ meeting, 05/10/2015 2 I added “MS_CSC_EA_DISCONNECTED_2” defect for CSC since AL05 layer 3 and 4 channels (1-96) dead. Relevant ELOG entries :https://atlasop.cern.ch/elisa/display/27910 6https://atlasop.cern.ch/elisa/display/27910 6 Problem didn’t appear in later runs.
3
Zhen YAN, Muon Offline DQ meeting, 05/10/2015 3 No major issues.
4
Zhen YAN, Muon Offline DQ meeting, 05/10/2015 4 No major issues except TGC HV glitch. No defects needed.
5
Zhen YAN, Muon Offline DQ meeting, 05/10/2015 5 General issues: CSC Link loss problem occurs time to time MDT Chamber drop/recovery during the run Pathological/Disabled chambers during long run (randomly) ~ 10 MLs consistently have low efficiency(<70%) on BIC & BIA (page 6) RPC Feet region sectors didn’t fully functional Data misalign on sector 25 Tower re-sync TGC SSW drop and ROD busy (TGC big storm errors) General comments : Inconsistent default ranges on some web display plots RPC coverage plots : BA A13 LowPt1 eta, BC C14 RO HighPt0/1 eta and phiBA A13 LowPt1 etaBC C14 RO HighPt0/1 eta and phi MDT ML efficiency plots : BIS8A10/A14 BML6A/C13 histogram missingBIS8A10/A14 BML6A/C13 histogram missing Z axis color scheme is good at efficiency plots but not quiet useful on some occupancy/hit plots due to noisy channel and geometry effect RPC GlobalHitsPerRPCOuter RPC GlobalHitsPerRPCOuter MDT OccupancyVsLB_ECInner MDT OccupancyVsLB_ECInner MDT BEE NumberOfHitsInBAExtraPerMultiLayer_ADCCut MDT BEE NumberOfHitsInBAExtraPerMultiLayer_ADCCut TGC Strip_Occupancy_Map_A TGC Strip_Occupancy_Map_A Segments_Z_chamberIndex_perSector Segments_Z_chamberIndex_perSector
6
Zhen YAN, Muon Offline DQ meeting, 05/10/2015 6
7
7 Backup slides
8
Zhen YAN, Muon Offline DQ meeting, 05/10/2015 8 Further concerning : ACR shifter Offline DQ shifter Usually offline DQ shifter has to dig out useful information based on the shift summary submitted by ACR shifter which they written with their personal style Online DQ report is the proper solution and it can be done with good shifter Sub-detector on-call expert Offline DQ shifter Join the DQ meeting every Monday, Wednesday and Friday Update the detector condition and known problems to DQ shifter in time Daily summary(like TGC) or Run base summary(DQ shifter) to ELOG Offline DQ expert Offline DQ shifter Specific explanation on those intolerable defects(documents, references and examples) Optimize/Tuning offline DQ plots Document more tracking plots(MCP part) if possible My concerning and proposal (just for leading discussion)
9
Zhen YAN, Muon Offline DQ meeting, 05/10/2015 9 Really good and useful DQ report from online Muon shifter “Carsten Bittrich” https://atlasop.cern.ch/elisa/display/279560 Could be even better if we specify the template with well pre-defined catalogue/checklist
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.