Presentation is loading. Please wait.

Presentation is loading. Please wait.

Physical Description of IceTop 3 Nov 2010 1 IceTop Internal Review Madison, November 3-4, 2010 Physical Description of IceTop Paul Evenson, University.

Similar presentations


Presentation on theme: "Physical Description of IceTop 3 Nov 2010 1 IceTop Internal Review Madison, November 3-4, 2010 Physical Description of IceTop Paul Evenson, University."— Presentation transcript:

1 Physical Description of IceTop 3 Nov 2010 1 IceTop Internal Review Madison, November 3-4, 2010 Physical Description of IceTop Paul Evenson, University of Delaware

2 Physical Description of IceTop 3 Nov 2010 2 Ice Cube Operation

3 Physical Description of IceTop 3 Nov 2010 3 The IceTop Square Kilometer Array Will consist of 82 “stations” One station located near each in-ice “string” plus two “infill” Uses the same surface data cable as the string Each station has two “tanks” separated by ten meters Local coincidence between the tanks in the station reduces trigger rate One low gain and one high gain DOM in each tank gives required dynamic range

4 Physical Description of IceTop 3 Nov 2010 4 Ice Top “Tanks” Emulate natural growth of lake ice. Produce clear ice by a method known in the materials industry as “zone refining” in which a crystal forming from the liquid phase excludes impurities, concentrating them in the remaining liquid. In a lake, “impurities” (which include the oxygen fish need to survive) are diluted in the large volume of lake water under the ice. Technical issues at Pole all derive from the need to conduct the freeze in and with a volume of water comparable to that of the end product.

5 Physical Description of IceTop 3 Nov 2010 5 IceTop Objective: Calibration Determine size (i.e. estimate energy) of cosmic-ray showers with E 0 > 300 TeV –Energy deposition of muon bundle in IceCube is correlated with E 0 IceTop direction gives tagged muon beam –SPASE-AMANDA proof of method

6 Physical Description of IceTop 3 Nov 2010 6 IceTop Objective: EeV  Detection via Shower Veto  This background for EeV events can be vetoed by detecting the fringe of the coincident horizontal air shower in an array of water Cherenkov detectors (cf. Ave et al., PRL 85 (2000) 2244, analysis of Haverah Park) Penetrating muon bundle in shower core Incident cosmic-ray nucleus Threshold ~ 10 17 eV to veto this background

7 Physical Description of IceTop 3 Nov 2010 7 IceTop Objective: Cosmic Ray Composition Coincident events: –Measure size at surface & energy deposition in deep detector –Primary energy and mass can be separately determined Signal in deep ice Signal in surface array

8 Physical Description of IceTop 3 Nov 2010 8 IceTop Capability: Heliospheric Physics IceTop array will detect a million muons every ten seconds Photons and electrons are also detected and to some extent can be resolved from muons Statistical precision for observing solar and heliospheric phenomena will greatly exceed that of neutron monitors Detailed analysis of IceTop signals will allow estimation of the top of atmosphere spectrum of primary protons in the 1-10 GeV energy range The energy coverage of IceTop is complementary to that of a neutron monitor

9 Physical Description of IceTop 3 Nov 2010 9 Degassing System Pump, filter, and contactor Submerged in tank to eliminate most leaks Only pump power and vacuum line emerge They exit through the pressure relief tube

10 Physical Description of IceTop 3 Nov 2010 10 Production Line

11 Physical Description of IceTop 3 Nov 2010 11 Dig a Trench and Position Tanks

12 Physical Description of IceTop 3 Nov 2010 12 Fill Tanks with Water

13 Physical Description of IceTop 3 Nov 2010 13 Install the Sunshade Metal frame with fabric surface Open at the top Opaque, with reflective white outer surface and black inner surface

14 Physical Description of IceTop 3 Nov 2010 14 Preparing to Close Tank Dual degassing units are seen under 75 cm of ice DOMs are frozen into the ice

15 Physical Description of IceTop 3 Nov 2010 15 Tank Closeout

16 Physical Description of IceTop 3 Nov 2010 16 Backfill Tank with  telescope

17 Physical Description of IceTop 3 Nov 2010 17 Key IceTop Parameters Are Maintained Online Configuration: http://wiki.icecube.wisc.edu/index.php/IceTop_Configurations Geometry: http://wiki.icecube.wisc.edu/index.php/IceTop_Tank_Geometry

18 Physical Description of IceTop 3 Nov 2010 18 Configuration Example

19 Physical Description of IceTop 3 Nov 2010 19 Geometry Example (Page Top)

20 Physical Description of IceTop 3 Nov 2010 20 Geometry Example Continued


Download ppt "Physical Description of IceTop 3 Nov 2010 1 IceTop Internal Review Madison, November 3-4, 2010 Physical Description of IceTop Paul Evenson, University."

Similar presentations


Ads by Google