FE-I4 irradiated chip tests at low temperature M. Menouni, P. Breugnon, A. Rozanov (CPPM - Aix-Marseille Université)
2
September 9, 2013irradiated FE-I4 tests at low temperature2 Introduction The FE-I4-B chip number 162 was irradiated in 2012 at CERN PS with 24 GeV protons close to the region of end of columns It received a total dose of 1200 Mrad (800 Mrad + 400 Mrad) Tests at room temperature Analog Tests Threshold level measurement and adjustment Threshold Scan and difficulties to tune Partial Tune results Tests at low temperature (-26 °C) Out1 DC levels measurements PrmpVbp I(V) measurements Conclusion
3
September 9, 2013irradiated FE-I4 tests at low temperature3 Analog Test Configuration parameters : Amp2Vbn=79 Amp2Vbp=85 Amp2VbpFoll=26 Amp2Vbpf=40 PrmpVbp=43 PrmpVbpf=100 Vthin_AltFine=120 TDACVbp =150 Power : Ivddd=219 mA and Ivdda= 422 mA Analog Test with Amp2Vbpf=40 and Vcal=400Analog Test with Amp2Vbpf=40 and Vcal=1000
4
Effective Threshold measurement DC levels measurements through OABUF The effective threshold value becomes high because of irradiation For the default value of Vthin_Altfine (= 120) Chip 162 : The mean value of measured VthEff is 0.85V Measured VthEff around 1.15 V for the chip 165 Decreasing the Vthin_Altfine to the minimum value does not help well The threshold still high >30000 e- beam spot center region In order to decrease the effective threshold: TDACVbp is set to the highest allowed value 255 instead of the standard value of 150 The Vtheff is increased to 0.933 V. The resultant threshold is ~6000 e- Drawback : increase the TDAC step For TDACVbp=255, the Analog test is OK with VCAL=400 September 9, 2013irradiated FE-I4 tests at low temperature4
5
September 9, 2013irradiated FE-I4 tests at low temperature5 Threshold Scan Threshold histogram before tuning Mean value=6269 e- and Sigma =840 e- The majority of pixels have a reasonable noise : 150 e- RMS This noise reaches 900 e- RMS in the beam spot center region (most irradiated region) Many pixels in 2 columns 15 and 16 are always at 1 (counting of 100%) Broken Columns : 15 and 16
6
September 9, 2013irradiated FE-I4 tests at low temperature6 TDAC Tune DAC TUNE launched with a target threshold of 6500 e- A strange resultant TDAC map. Only 2 values 16 and 24 are used for tune Most of TDAC values are set to 16 TDAC = 24 in the beam spot center region High disparity between thresholds in high and low irradiated regions makes the tuning failed In order to make the TDAC Tune possible : Regions with a very high threshold are disabled DC number 16 to 28 are disabled The 2 columns in the left-middle of the chip are also disabled DC number 8 to 9 disabled
7
September 9, 2013irradiated FE-I4 tests at low temperature7 TDAC Tune results Threshold Scan at room temperature Threshold histogram after tuning : Mean value=5511 e- Sigma =143 e- The tuning resolution is high because of the high threshold difference before tuning (and TDACVbp = 255 ?) Noise : 143 e- RMS
8
TDAC Map TDAC value at 16 : disabled pixels High TDAC values for pixels near the beam spot center region Values from 0 to 8 not used during tuning Tuning could be re-optimized September 9, 2013irradiated FE-I4 tests at low temperature8
9
Test at Low Temperature (-26°C) Same configuration file at -26 °C as for room temperature Threshold Scan shows a global mean value of 3612 e- Individual Scurves show a threshold above 10000 e- in the beam center region The noise value is similar to the value at room temperature (150 e- RMS). It reaches 700-800 e- RMS near the center region Columns 15 and 16: many pixels are always counting 100%. Level stuck to "1" September 9, 2013irradiated FE-I4 tests at low temperature9
10
TDAC Tune at low temperature (-26°C) Tune with 4000 e- as target value TDAC Tune failed for the whole array Partial Tune : DC 8-9 and DC 18->26 disabled After tuning Threshold Mean value=3959 e- Sigma =237e- The tuning resolution is high because of the high threshold disparity before tuning September 9, 2013irradiated FE-I4 tests at low temperature10
11
TDAC Map TDAC value at 16 for disabled pixels High TDAC values for pixels near the beam center region September 9, 2013irradiated FE-I4 tests at low temperature11
12
DC level of out1 DC levels measured for out1, out2 and vtheff through the OABUF The out1 DC values are higher for the chip 162 Lowest value for the chip 162 : 356 mV Lowest value for the chip 165 is 230 mV LBL measurements on the chip Ch27 show a lower DC value (80mV to 120 mV) The chip 162 and 165 can be partially tuned even for the PrmpVbp value of 43 September 9, 2013irradiated FE-I4 tests at low temperature12 LBL Ch27 chip Chip 165 Chip 162
13
September 9, 2013irradiated FE-I4 tests at low temperature13 PrmpVbp I(V) We don’t observe the high gate leakage current behavior for both irradiated chips (165 and 162) PrmpVbp I(V) measurements show an increase in the threshold voltage for the pmos transistors. This increase is especially high for the chip 162
14
September 9, 2013irradiated FE-I4 tests at low temperature14 Conclusion The chip 162 irradiated to a dose level of 1200 Mrad can be tuned partially at room and at low temperature The whole array tune is failed because of the high disparity on the thresholds for high and low irradiated regions Configuration parameters to set in order to reduce this disparity ? An optimal Bias for the preamplifier and amplifier The effective threshold voltage can not be set to a low values for the irradiated chip 162 TDACVbp set to 255 Other parameters to change ? High gate leakage current behavior is not observed for the irradiated chip 165 (400 Mard) or for the irradiated chip162(1200 Mrad)